Dell PowerVault NX3000 Hardware Owner's Manual page 46

Powervault nx3000 systems
Hide thumbs Also See for PowerVault NX3000:
Table of Contents

Advertisement

Table 1-2. System Messages (continued)
Message
Plug & Play
Configuration
Error
Quad rank DIMM
detected after
single rank or
dual rank DIMM in
socket.
Read fault
Requested sector
not found
SATA Port x device
not found
46
About Your System
Causes
Error encountered in
initializing PCIe device;
faulty system board.
Invalid memory
configuration.
The operating system cannot
read from the hard drive,
optical drive, or USB device,
the system could not find a
particular sector on the disk,
or the requested sector is
defective.
There is no device connected
to the specified SATA port.
Corrective Actions
Install the NVRAM_CLR
jumper in the clear position
(pins 1 and 3) and reboot the
system. See Figure 6-1 for
jumper location. If the
problem persists, see
"Troubleshooting Expansion
Cards."
Ensure that the memory
modules are installed in a
valid configuration. See
"General Memory Module
Installation Guidelines."
Replace the optical medium,
USB medium or device.
Ensure that the SAS
backplane, USB, or SATA
cables are properly
connected. See
"Troubleshooting a USB
Device," "Troubleshooting an
Optical Drive," or
"Troubleshooting a Hard
Drive" for the appropriate
drive(s) installed in your
system.
Information only.

Advertisement

Table of Contents
loading

Table of Contents