Table 1-1. LCD Status Messages (continued)
Code
Text
E1A14 SAS cable A
failure.
Check
connection.
E1A15 SAS cable B
failure.
Check
connection.
E1A1D Control panel
USB cable not
detected.
Check cable.
E2010 Memory not
detected.
Inspect
DIMMs.
E2011 Memory
configuration
failure.
Check DIMMs.
E2012 Memory
configured
but unusable.
Check DIMMs.
E2013 BIOS unable
to shadow
memory. Check
DIMMs.
32
About Your System
Cause
SAS cable A is missing or
bad.
SAS cable B is missing or
bad.
USB cable to the control
panel is missing or bad.
No memory was detected in
the system.
Memory detected, but is
not configurable. Error
detected during memory
configuration.
Memory configured, but is
unusable.
The system BIOS failed to
copy its flash image into
memory.
Corrective Actions
Reseat the cable. If the
problem persists, replace
cable.
If the problem persists,
see "Getting Help."
Reseat the cable. If the
problem persists, replace
cable.
If the problem persists,
see "Getting Help."
Reseat the cable. If the
problem persists, replace
cable.
If the problem persists,
see "Getting Help."
Install memory or reseat
the memory modules. See
"Installing Memory
Modules" or
"Troubleshooting System
Memory."
See "Troubleshooting
System Memory."
See "Troubleshooting
System Memory."
See "Troubleshooting
System Memory."

Advertisement

Table of Contents
loading

Table of Contents