Overview
1.1 Product Overview
Provides information for installing MAX-X Series solar inverters. Read carefully before use.
1.2 Applicable Personnel
Only qualified electrical technicians should install the inverter. Follow precautions.
Safety Precautions
2.1 Safety Overview
Read manual before installation to avoid warranty void. Use qualified technicians.
2.2 Symbol Conventions
Explains symbols for danger, warning, caution, and notice.
2.3 Label Description
Describes labels like high voltage, burn warning, grounding, and CE mark.
Product Introduction
3.1 Appearance
Details the physical components of the inverter through diagrams and labels.
3.2 Basic Data
Provides physical dimensions and weight for the inverter models.
3.3 Nameplate
Lists key technical specifications found on the inverter's nameplate.
3.4 Working Principle
Explains how the MAX-X series inverter converts DC to AC and connects to the grid.
3.5 Inverter Storage
Guidelines for storing the inverter, including environmental conditions and stacking.
3.6 Grid Types
Illustrates how different MAX-X series inverters connect to the grid.
3.7 AFCI Detection Function
Describes the optional Arc Fault Circuit Interrupter function for fire prevention.
3.8 Anti-PID Function
Explains the optional function to counteract Potential Induced Degradation.
Unpacking
4 Unpacking
Instructions for checking and verifying the contents of the inverter package.
Installation
5.1 Basic Installation Requirements
Covers requirements for wall solidity, space, flammability, and orientation.
5.2 Installation Environment Requirements
Guidelines for avoiding rain, snow, direct sunlight, and ensuring proper ventilation.
5.3 Moving Requirements
Safety precautions and methods for safely moving the heavy inverter.
5.4 Wall Mount Bracket Installation
Step-by-step guide for installing the wall mount bracket securely.
5.5 Installing The Inverter
Procedures for physically mounting the inverter onto the installed bracket.
Connecting Cables
6.1 Connection on AC side
Details on connecting the AC power cables, including safety warnings.
6.2 Connection On DC Side
Instructions and safety precautions for connecting the DC input cables from PV panels.
6.3 Connection Of Communication Cables
How to connect communication cables (RS485, USB) for monitoring and control.
6.4 Connecting The Ground Cables
Procedures for proper grounding of the inverter for safety and lightning protection.
System Commissioning
7.1 Commission The Inverter
Steps to set up the inverter after installation, including time and address.
7.1.1 Set inverter address
How to set a unique communication address for the inverter.
7.1.1.1 Set RS485 address with Shinebus
Modifying the inverter's 485 address using Shinebus software.
7.1.1.2 Set RS485 address on ShinePhone APP
Setting the inverter's 485 address via the ShinePhone mobile application.
7.1.2 Set inverter time and date
Instructions for setting the inverter's internal clock and date.
7.2 Operation Mode
Explains the different operating states of the inverter (waiting, working, off).
7.2.1 Waiting mode
Describes the state when the inverter is powered on but not yet connected to the grid.
7.2.2 Working mode
Details the normal operating state where the inverter converts DC to AC.
7.2.3 Fault mode
How the inverter indicates faults via LED status.
7.2.4 Off mode
Conditions under which the inverter automatically stops working.
7.3 LED Display
Explains the meaning of different LED indicators on the inverter.
Monitoring
8.1 Remote Data Monitoring
Methods for monitoring inverter performance remotely via APP or web.
8.1.1 Mobile phone APP(ShinePhone) remote monitoring
Guide to using the ShinePhone app for remote monitoring.
8.2 Local Data Monitoring
Methods for monitoring inverter data locally via app or PC.
8.2.1 Mobile phone app (Shinephone) Local Monitoring
Using the ShinePhone app for local monitoring and Wi-Fi configuration.
8.2.1.1 Log on to app for local monitoring
Steps to log in and access local monitoring features on the ShinePhone app.
8.2.1.2 Use of local monitoring and debugging
How to view data, control settings, and debug the inverter locally.
8.2.2 U Disk Monitoring
Using a U disk for firmware programming, fault recording, and curve analysis.
8.1.2 GPRS /4G
Details on registering accounts and adding devices for GPRS/4G monitoring.
Maintenance
9.1 Routine Maintenance
General maintenance tasks for the inverter, including cleaning.
9.1.1 Cleaning Inverter
Specific steps for cleaning the inverter, ensuring safety precautions are followed.
9.1.2 Fan Maintenance
Procedures for cleaning or replacing the inverter's internal and external fans.
9.2 Trouble Shooting
Guidance for diagnosing and resolving issues with the inverter.
9.2.1 Warning
Explains inverter warning codes and how they affect operation.
Product Specification
10 Specification
Comprehensive technical specifications for various MAX-X series inverter models.
Decommissioning
11 Decommissioning
Steps to safely disconnect and remove the inverter from operation.
11.1 Disposing Of The MAX-X Series Inverter
Guidelines for the proper disposal of the inverter as electronic waste.
Quality assurance
12 Quality assurance
Information regarding the quality assurance of Growatt products.
Contact Us
13 Contact Us
Information on how to contact Growatt for technical support and issues.