GR-UM-320-A-02 (PN: 044.0108502)
MID 10-30KTL3-XH
&
User Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MID 10KTL3-XH and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Growatt MID 10KTL3-XH

  • Page 1 MID 10-30KTL3-XH & User Manual Download Manual Shenzhen Growatt New Energy Co., Ltd. 4-13/F, Building A, Sino-German (Europe) Industrial Park, Hangcheng Ave, Bao'an District, Shenzhen, China +86 755 2747 1942 service@ginverter.com en.growatt.com GR-UM-320-A-02 (PN: 044.0108502)
  • Page 2 All products, services and features are stipulated by the contract made between Growatt and the customer. All or part of the products, services and features described in this document may not fall under the scope of purchase or usage. Unless otherwise specified in the contract, Growatt makes no representations or warranties, express or implied with respect to this documentation.
  • Page 3 First release The content of this document is continually reviewed and amended, where necessary. However, discrepancies cannot be excluded. Growatt reserves the right to make changes to the material at any time and without notice in order to keep the document accurate and up-to-date.
  • Page 4: Symbols In This Manual

    Symbol convention Symbols in this manual Direct Current (DC) The following safety symbols are used throughout this document to denote important safety information. Familiarize yourself with the symbols and their meaning before installing or operating this instrument. Alternating Current (AC) Symbol Meaning Refer to the manual...
  • Page 5: Table Of Contents

    2.6.5 Demand Response Modes (DRMs) & Radio Ripple Control Receiver 5.9 Connecting the meter (optional)................37 (RRCR)........................14 5.9.1 Connecting Growatt smart meter ................38 2.6.6 Dry contact........................ 15 5.9.2 Connecting Eastron smart meter ................40 2.6.7 AFCI (Arc Fault Circuit Interrupter)................ 15 5.9.3 Connecting CHINT smart meter ................
  • Page 6 6.1 OLED control........................ 49 8.8 Power de-rating for voltage variation (Volt-Watt mode) ......... 68 6.2 Setting the language ....................49 8.9 Reactive power regulation for voltage variation (Volt-VAR mode)......68 6.3 Setting the communication address................49 9 System maintenance................69 6.4 Setting the country/area .....................
  • Page 7: Safety Precautions

    Check the equipment for damage before starting installation. Information Information Growatt shall not be held liable for any damage caused by the following circumstances: Ÿ Ÿ Use the product beyond the conditions specified in this manual or failure to meet the...
  • Page 8 1.1.3.3 Using a ladder Ÿ Follow the wiring instructions specified in the user manual; otherwise, any device damage caused by improper wiring will not Ÿ Any work which is performed 2 meters or more is known as work at be covered under any warranty. heights.
  • Page 9: Product Overview

    2 Product overview 2.2 Working principle 2.1 Introduction The MID 11-20KTL3-XH inverter features 2 independent MPPT (maximum power point tracking) channels and up to 2 strings may be connected per MPPT. The MID 25- Features 30KTL3-XH inverter features 3 independent MPPT channels and up to 2 strings may be The MID TL3-XH is a high-quality Hybrid Inverter designed to convert solar energy into connected per MPPT.
  • Page 10: Application Scenarios

    Table 2-2 Operating mode description 2.4.2 Grid-tied inverters connected in parallel Operating Description Ÿ The MID TL3-XH inverters can be connected in parallel. To enable status the parallel operation, a ShineMaster-X or SEM-X should be Receive a shutdown command or the PV voltage does not meet installed.
  • Page 11: Operating Mode

    Figure 2-5 Partial backup system 2.5 Operating mode ShineServer Ÿ The MID TL3-XH inverter offers three operating modes and 9 configurable time segments, enabling to operate the inverter in a specific mode during different periods. For details, please refer to Datalogger Cloud Server Section 8.4 Setting the operating modes.
  • Page 12 The MID TL3-XH inverters support the Backup function. To enable Output power Model this feature, you need to purchase the SYN BOX (SYN 100-XH-30) and a compatible battery system (APX 98034-P2). Refer to section MID 10KTL3-XH 10kW 10kW 10kW 10kW 10kW 8.5 Backup function (Optional) for instructions on enabling this...
  • Page 13 Demand Response Modes (DRMs), with DRM 0 being a mandatory requirement. The DRMs is set to disabled by default. To enable it, please contact Growatt customer support. For details, please refer to Section 8.2 DRMs & Remote logic control.
  • Page 14: Inspection Upon Delivery

    When the PV modules or the cables are in poor contact or damaged, an electrical arc may occur on the DC side, which might lead to a fire hazard. Growatt inverters are integrated with an arc-fault detection function in compliance with UL1699B-2018 Installation standards.
  • Page 15: Moving The Inverter

    ① The number of PV connectors for 10K-20K inverters is 4/4. The number of PV connectors for 25K-30K and Australian MID 10-30KTL3-XH. inverters is 6/6. 3.4 Dimensions and weight ② The number of PV metal contacts for 10K-20K inverters is 4/4. 3.4.1 Dimensions of the package The number of PV metal contacts for 25K-30K and Australian MID 10-30KTL3-XH.
  • Page 16: Installation

    4 Installation 4.1 Required tools Figure 4-1 Environment requirements Table 4-1 Installation tools Tools Drilling bit Cross-head Hammer drill Hammer Level (Ф=10 mm) screwdriver Figure 4-2 Installing an awning and clearance requirements Vacuum Marker Measuring tape Heat gun Multimeter ≥300mm ≥1000mm Slanted Wire stripper...
  • Page 17 4.2.2.1 Angle requirements When multiple inverters are installed, please refer to the following figures to maintain proper clearances: Figure 4-3 Angle requirements Figure 4-5 Horizontal installation ≥500mm ≥500mm Ground Roof Figure 4-6 Two-row staggered installation 4.2.2.2 Space requirements Ÿ To ensure optimal operation of the inverter and facilitate ease of operation, please reserve enough space around the inverter.
  • Page 18: Wall-Mounted Installation

    4.3 Wall-mounted installation 4.3.2 Installing the inverter 4.3.1 Installing the mounting bracket Ÿ Prior to installing the inverter, ensure that the mounting bracket is securely installed. Ÿ Electrical connections can only be performed after the securing Ÿ Operation personnel should wear goggles and dust masks when Information screws are tightened.
  • Page 19: Electrical Connection

    Growatt Ÿ DANGER Unqualified persons shall not perform any electrical shall not be liable for the consequences.
  • Page 20: Connecting The Grounding Cable

    Ÿ When using a heat gun, please take precautions to avoid exception occurs, which might lead to severe damage. Growatt equipment burns. shall not be liable for the consequences.
  • Page 21: Connecting The Dc Input Cable

    Figure 5-3 Threading cables through the waterproof connector Figure 5-6 Connecting the AC output power cable >150mm 5 N·m Step 4. Securing the waterproof terminal Figure 5-7 Tightening the screw to secure the waterproof cover Note: Do not thread cables with crimped terminals through the waterproof connector to avoid damaging the rubber lining.
  • Page 22: Connecting The Communication Cable

    Ÿ Crimp the PV metal contact with a dedicated crimper. Using an Ÿ In cases where the inverter has no isolated transformer for its inappropriate crimping tool may lead to severe consequences, and output, the negative pole of the PV panel is energized and any device damage caused by this is not covered by the warranty.
  • Page 23: Com Port Definition

    5.7.1 COM port definition 5.7.2 Connecting the 30-pin COM connector Figure 5-10 30-pin COM port Strip the cable to a length of 10 mm then pass it through the waterproof connector cover and the threaded sleeve. Crimp the corresponding terminal provided in the accessory bag onto the communication cable, and plug in the 30-pin communication connector.
  • Page 24: Connecting A Single Battery Cluster

    5.8.1 Connecting a single battery cluster 5.8.2 Connecting multiple battery clusters For details, please refer to the user manual of the battery or scan the QR code below. Figure 5-13 Connecting multiple battery clusters MID10-30KTL3-XH COM port Figure 5-12 Connecting a single battery cluster 1 2 3 4 5 6 7 8 1 →...
  • Page 25: Connecting The Meter (Optional)

    To enable these functions, an external smart meter is required. Please Dimensions 90*45*65mm (excluding the buckle) purchase the meter from Growatt and the recommended model is the TPM-CT-G 100A smart meter. NOTICE Ÿ IP20 (indoor)...
  • Page 26 5.9.1.2 3P4W wiring Figure 5-15 3P4W System (with a Growatt smart meter) Ÿ K→L is printed on the CT. K refers to the grid side and L refers to the load side. Information 5.9.1.1 3P3W wiring Grid Figure 5-14 3P3W System (with a Growatt smart meter)
  • Page 27 Figure 5-16 3P3W System (with an Eastron smart meter) Manufacturer Eastron Over current withstand 20Imax for 0.5s Pulse output 1 1000imp/kWh (default) Grid Pulse output 2 400imp/kWh Display Max. Reading LCD with white backlit 999999kWh Environment Operating temperature -25℃to +55℃ Storage and transportation temperature -40℃to +70℃...
  • Page 28 5.9.3 Connecting CHINT smart meter Mechanics Table 5-7 CHINT smart meter specific parameters Din rail dimensions 100×72×65mm (LxW×H) General specifications Mounting DIN rail 35mm Rate voltage 3×230/400Vac Sealing IP61(indoor) Reference frequency 50Hz/60Hz Specified operating voltage range 0.9Un~1.1Un Ÿ Pin 1/2/3/4 of the meter are connected to the grid and Pin 5/6/7/8 to the inverter.
  • Page 29: Connecting The Syn Box (Optional)

    5.11.1 System wiring 5.10 Connecting the SYN BOX (optional) Figure 5-20 Parallel system wiring diagram MID TL3-X MID TL3-XH Ÿ Grid The MID TL3-XH inverter supports to be connected to the SYN BOX (the SYN 100-XH-30 backup box is recommended). Ÿ...
  • Page 30: Configuration

    With a datalogger connected, the MID TL3-XH inverter can be monitored via the cloud server and the APP. Recommended datalogger model: Table 5-10 Datalogger specifications ShineLan-X Configuration Guide Brand Recommended model Applicable system Ÿ GROWATT ShineWiFi-X A single inverter Ÿ GROWATT ShineLan-X A single inverter Ÿ ShineLink-X Configuration Guide...
  • Page 31: Human-Machine Interaction

    6 Human-machine interaction 6.1 OLED control 6.4 Setting the country/area Table 6-1 Touch button Single tap to view the options or increase the number by one; double tap to confirm your settings. The password for advanced settings is 123. After entering the password, Symbol Description Explanation...
  • Page 32: Restoring To Factory Settings

    you can enable the backup mode on the OLED screen. Single tap to view the options or Single tap Set OK Setting... increase the number by one; double tap to confirm your setting. Configure the backup mode as illustrated below: Single tap Double tap Triple tap...
  • Page 33 Note: Setting the following parameters on the ShinePhone APP or Table 7-1 Checking items the Server webpage requires the password. To access the Checking items Criteria password, please contact Growatt service personnel. Information Installation of the The inverter is securely installed inverter 8.1 Setting the export limitation...
  • Page 34 8.1.3 On the Server webpage Step1. Log in with your Server account Step2. Setting > Export limit setting > Enable > Set the Phase level Ÿ Phase-level export limitation is disabled by default, and can only be enabled when connected to the APX battery. NOTICE...
  • Page 35 8.2 DRM s & R emote logi c control Mode Switches on DRED Function Ÿ M ak e sure the cable g land s have been ti g htene d firml y . Ÿ If the cabl e glands are n ot mou nte d properly, the inverter can be Do not consume at more DRM 3 d es troyed due to moisture and dust penetrati on.
  • Page 36 Table 8-2 RRCR wiring description DRM Socket Pin NO. Description Connected to RRCR Relay contact 1 input K1 – Relay 1 output Relay contact 2 input K2 – Relay 2 output Relay contact 3 input K3 – Relay 3 output Relay contact 4 input K4 –...
  • Page 37 8.3.2 On the ShinePhone APP 8.4 Setting the operating modes Ÿ The time periods should not overlap; otherwise, the configuration would fail. Ÿ After setting the parameters, please verify that the parameter changes have been successfully adopted. WARNING 8.4.1 On the Server webpage Step 1.
  • Page 38 8.5 Backup function (optional) Ÿ When wiring the SYN, please refer to the silk screen inside the box; otherwise, the device might be damaged. Growatt shall not be liable for device damage caused by incorrect wiring. Ÿ The bypass breaker and the circuit breaker of the inverter cannot...
  • Page 39 8.5.3 Setting the off-grid function on the ShinePhone APP 8.6 AFCI 8.6.1 Enabling the AFCI function 8.6.1.1 On the Server webpage Step 1. Log in with your Server account, then click “Setting”. Step 2. Select Regulation parameter setting > AFCI On > On > Yes.
  • Page 40: Power De-Rating For Voltage Variation (Volt-Watt Mode)

    8.6.1.2 On the ShinePhone APP 8.7 Setting the COM address of the inverter When multiple inverters are connected in parallel, connect the parallel communication terminal on the inverter to the datalogger and set different COM addresses to the inverters, ranging from 1 to 254;...
  • Page 41: System Maintenance

    9 System maintenance Decommissioning 10 10.1 Removing the inverter To ensure the long-term and reliable operation of the system, it is recommended to perform maintenance on a regular basis as instructed in this section. Ÿ Disconnect all electrical connections from the inverter, including the RS485 communication cable, DC input cables, AC output cables, battery cables, and the Ÿ...
  • Page 42: Specification

    11 S p e c i f i c a t i o n Model 11.1 MID 11-30KTL3-XH series Specifications 11KTL3-XH 12KTL3-XH 13KTL3-XH 15KTL3-XH Model Max. output overcurrent 74.1A 11KTL3-XH 12KTL3-XH 13KTL3-XH 15KTL3-XH Specifications Protection Power factor(@nominal Input data (DC) >0.99 power) Recommended Max.
  • Page 43 Model Model Specifications 11KTL3-XH 12KTL3-XH 13KTL3-XH 15KTL3-XH 17KTL3-XH 20KTL3-XH 25KTL3-XH 30KTL3-XH Specifications Residual-current Input data (DC) monitoring unit Recommended Max. PV 34000W 40000W 50000W 60000W String fuse protection power (for module STC) Max. DC voltage 1100V String monitoring Start voltage 200V AFCI protection Configurable...
  • Page 44 Model Model 17KTL3-XH 20KTL3-XH 25KTL3-XH 30KTL3-XH Specifications 17KTL3-XH 20KTL3-XH 25KTL3-XH 30KTL3-XH Specifications Power factor(@nominal String fuse protection >0.99 power) String monitoring THDi <3% AC grid connection type 3W+N+PE AFCI protection Configurable Efficiency General data Max. efficiency 98.00% Dimensions (W / H / D) 579*433*217.5mm in mm Euro-eta...
  • Page 45: Australian Mid 10-30Ktl3-Xh Series

    11.2 Australian MID 10-30KTL3-XH series Model MID 10KTL3 MID11KTL 3 MID 12KTL3 MID13 KTL3 MID 15KTL3 S pecifications Model MID 10KTL3 MID11KTL3 MID 12KTL3 MID13KTL3 MID 15KTL3 Max. o utput current 14.5A 15.9 A 17.4A 18.8A 21.7A Specifications AC inrush current Input data (DC) Max.
  • Page 46 Model Model MID 10KTL3 MID11KTL3 MID 12KTL3 MID13KTL3 MID 15KTL3 MID 17KTL3 MID 20KTL3 MID 25KTL3 MID 30KTL3 Specifications Specifications Insulation resistance Input data (DC) monitoring Recommended Max. PV 34000W 40000W 50000W 60000W AC surge protection power (for module STC) AC short-circuit Max.
  • Page 47 Model Model MID 17KTL3 MID 20KTL3 MID 25KTL3 MID 30KTL3 MID 17KTL3 MID 20KTL3 MID 25KTL3 MID 30KTL3 Specifications Specifications Max. output overcurrent Class Ⅰ Class of equipment 74.1A 106.7A Protection OVC Ⅲ Power factor(@nominal Overvoltage catagory Mains >0.99 power) OVCⅡ...
  • Page 48: Functions

    Description Troubleshooting red when a fault occurs, indicating that a system fault or an inverter fault has occurred. message In some cases, you may need to contact Growatt for technical assistance. 1. Restart the inverter. 12.1 System alarm Warning 217 BDC abnormal 2.
  • Page 49 1. Restart the inverter. Over- Communicatio 1. Check the communication wiring of the backup Warning 407 2. If the error message persists, contact Growatt temperature n with the box after powering off the device. support. Warning 607 backup box is 2.
  • Page 50: B A Tt E Ry Al A

    Troubleshooting 1. Power off the machine and check the Battery Battery Abnormal communication cables between BM and BM, then Abnormal Warning Please contact Growatt support. Warning communication restart the machine. EEPROM 404(0) 500(9) with PM 2. If the fault message still exists, contact the manufacturer.
  • Page 51: System Fault

    1. Restart the inverter. upper threshold permissible range and the error message Error 401 component in 2. If the error message persists, contact Growatt persists, please contact Growatt support. output voltage support. V panels have 1. Check if the PV strings are properly grounded.
  • Page 52 2. If the error message persists, please contact Growatt support. BOOST short- Error 428 Please contact Growatt support. circuited 1. Power off the system and check if the backup box split-phase transformer and the control relay Off-grid split- 1. Restart the inverter.
  • Page 53 2. If the error message persists, please contact Error 404(0) undervoltage 2. If the fault message still exists, contact the Growatt support. manufacturer. 1. Restart the backup box. 1. Power off the machine and check the power Backup box on-...
  • Page 54 Error code Description Troubleshooting 1. Power off the machine and check the Battery PM fuse open Multiple Masters communication cables between PM and INV, Please contact Growatt support. Error 506(2) circuited Battery parallel then restart the machine. Error 411(7) communication 2.
  • Page 55: Eu Declaration Of Conformity

    •2011/65/EU RoHS Directive and its amendment (EU)2015/863 Serial Number Format: LSLxxxxxx Shenzhen Growatt New Energy Co. Ltd confirms that the Growatt inverters and accessories described in this document are in compliance with the above-mentioned EU directives. The entire EU Declaration of Conformity can be found at...

Table of Contents