  • Page 2 At the presence of high frequency interference in the frequency range of 15 MHz to 50 MHz there may be performance restrictions. Relevant for IDM Corded Hand-held scanners Relevant for IDM Bluetooth Hand-held scanners © SICK AG · Germany · All rights reserved · Subject to change without notice 8017159/2014-04-24...
  • Page 3: Table Of Contents

    3.4.2 Suffix, Preamble, Postamble, FNC1 Transmit, Caps Lock ..........33 3.4.3 Delay Settings ........................34 3.4.4 Function Key & Key Pad Emulation, Upper/Lower Case ..........35 8017159/2014-04-24 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 4 3.9.8 Aiming, Delay Aiming Time-out, Decode Aiming .............. 82 3.9.9 Center Alignment, Unique Barcode Reporting ..............83 3.9.10 1D Barcode Reading Direction ..................84 © SICK AG · Germany · All rights reserved · Subject to change without notice 8017159/2014-04-24...
  • Page 5 5.8.2 2D Corded Scanners (IDM2x0 series) ................116 5.8.3 Bluetooth Scanners ......................116 Link Mode Quick Set ........................117 5.10 System Commands ........................118 5.11 Option Codes ..........................120 8017159/2014-04-24 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 6: Getting Familiar With Your Idm Hand-Held Scanner

    IDM241 Series Link Indicator Status Indicator Beeper Scan Window Trigger IDM160 BT Series IDM261 Series Battery Cavity End Cap Tether Plate Lanyard catch Retaining Screw © SICK AG · Germany · All rights reserved · Subject to change without notice 8017159/2014-04-24...
  • Page 7 Status Indicators Paging/ reset button USB Bus Power Switch IDM160 BT/ IDM261 Smart Cradle IDMx6x Charging Cradle Host interface port DC Power Jack Reserved 8017159/2014-04-24 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 8: Connectivity

    USB is not suitable for use in industrial environments. Therefore, at cable installation it is important to ensure that there are no close sources of interference. © SICK AG · Germany · All rights reserved · Subject to change without notice 8017159/2014-04-24...
  • Page 9: Industrial Fieldbus

    The IDM Hand-held scanners can be connected to industrial fieldbuses (such as PROFIBUS, PROFINET, Ethernet TCP/IP, DeviceNet, etc.) via SICK connection modules and an adapter cable. The adapter cable includes a voltage converter from DC 24 to 5 V for the voltage supply of the hand-held scanner, eliminating the need of a separate power supply.
  • Page 10: Technical Specifications

    Valid for Data Matrix Depending on scanner version (PDF version is necessary). Depending on scanner version (DPM version is necessary). Optional via external SICK connection modules. © SICK AG · Germany · All rights reserved · Subject to change without notice 8017159/2014-04-24...
  • Page 11: Idm Bluetooth Hand-Held Scanners

    For detailed technical specifications, see the Online Data Sheet on the product site on the web (www.mysick.com/en). Depending on scanner version (PDF version is necessary). Depending on scanner version (DPM version is necessary). Optional via external SICK connection modules. 8017159/2014-04-24 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 12: Idm Bluetooth Scanners

    When the battery is fully charged, the status indicator of the scanner turns steady green. Please note the important battery information on the next page! © SICK AG · Germany · All rights reserved · Subject to change without notice 8017159/2014-04-24...
  • Page 13: Placing The Scanner Into The Cradle

    If only USB 2.0 is available in your host device the external power supply is necessary as a power source, because the power supplied from USB 2.0 is not enough to support both battery charging and regular operation simultaneously. 8017159/2014-04-24 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 14: Indications

    Steady red Short click Time out warning 3 long beeps Paged by smart cradle 6 page beeps Sleep state / Battery no power Power Off © SICK AG · Germany · All rights reserved · Subject to change without notice 8017159/2014-04-24...
  • Page 15: Paging Function

    SPP mode or HID mode. When the radio link is disconnected, the scanner is capable of reconnecting the radio link automatically when it returns into the Bluetooth radio range area. Please note 8017159/2014-04-24 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 16: Pair Mode

    5 seconds. If you just want to un-pair part of the paired scanners, please take those paired scanners and scan the “Uninstall” command. © SICK AG · Germany · All rights reserved · Subject to change without notice 8017159/2014-04-24...
  • Page 17 “Save Configuration” command. Afterwards, please take the other paired scanners to scan the “Clone” command one by one to clone the host interface related parameters. 8017159/2014-04-24 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 18: Hid Mode

    In some cases, you may be requested to enter the Passkey (PIN) to establish the Bluetooth connection for security purpose. © SICK AG · Germany · All rights reserved · Subject to change without notice 8017159/2014-04-24...
  • Page 19 The above procedures are based on popular Windows environment. However, the installation procedure may vary depending on different remote host devices, operating systems and the Bluetooth drivers. 8017159/2014-04-24 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 20: Ssp Master/ Slave Mode

    The above procedures are based on popular Windows environment. However, the installation procedure may vary depending on different remote host devices, operating systems and the Bluetooth drivers. © SICK AG · Germany · All rights reserved · Subject to change without notice 8017159/2014-04-24...
  • Page 21: Out-Of-Range Scanning

    If the scanner is out of radio coverage, you will hear 4 beeps in descending tone to indicate the loss of radio connection. The link indicator of the scanner will give 3 blue blinks per 2 seconds. Once the scanner is back 8017159/2014-04-24 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 22: Presentation Scanning

    2 long beeps and the status indicator will give 2 red blinks to indicate out of storage. To terminate the batch scanning, please scan the “Exit Batch Scanning” command. Enter Batch Scanning Exit Batch Scanning © SICK AG · Germany · All rights reserved · Subject to change without notice 8017159/2014-04-24...
  • Page 23: Quantity Feature

    To fulfill different application requirements, both the delimiter and the output sequence can be changed. As many times as the quantity indicates  <Field delimiter><Quantity><Scanned data> <Scanned data><Field delimiter><Quantity> 8017159/2014-04-24 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 24: Transmit Stored Data

    However you are also able to change the setting to “Auto Delete Stored Data after transmission”. (Refer to chapter 3.10.3) Clear all Stored Data © SICK AG · Germany · All rights reserved · Subject to change without notice 8017159/2014-04-24...
  • Page 25: Configuration Via Barcodes

    “Cycling Scan Selection” or “Dual Level Selection” to complete their programming procedures. Each kind of programming procedure is listed in the following pages for your reference. Please give careful attention to become familiar with each programming procedure. 8017159/2014-04-24 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 26: Program & End

    ASIC or non-volatile memory after you scan the “END”. Please don’t turn off the power before the completion beeping. It may destroy all configured parameters. © SICK AG · Germany · All rights reserved · Subject to change without notice 8017159/2014-04-24...
  • Page 27: System List & Master Default

    Select one option code for the desired codes parameter. Do you want to select another Repeat programming family? selection Scan Exit programming mode. „END“ 8017159/2014-04-24 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 28: Multiple Scan

    If it‘s necessary scan „FIN“ to terminate the option code selection. Do you want to select another Repeat programming family? selection Scan Exit programming mode. „END“ © SICK AG · Germany · All rights reserved · Subject to change without notice 8017159/2014-04-24...
  • Page 29: Cycling Scan

    “Multiple” scan selection. Finish cycling selection. (If necessary) Scan “FIN” Do you want to select another Repeat programming family? selection Scan Exit programming mode. „END“ 8017159/2014-04-24 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 30: Dual Level Scan

    ) Scan one or terminate the option code several option codes selection. Do you want to select another Repeat programming family? selection Scan Exit programming mode. „END“ © SICK AG · Germany · All rights reserved · Subject to change without notice 8017159/2014-04-24...
  • Page 31: Host Interface Selection

    USB HID standard mode  USB HID turbo mode USB HID Legacy IDM2xx series doesn’t support Wand emulation, Laser emulation and USB HID Legacy 8017159/2014-04-24 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 32: Keyboard Interface Control

    Suffix Symbol ID Postamble Record Suffix 1-15 2-4 digits 1 or 3 characters Variable 1 or 3 characters 1-15 1 character characters length characters © SICK AG · Germany · All rights reserved · Subject to change without notice 8017159/2014-04-24...
  • Page 33: Suffix, Preamble, Postamble, Fnc1 Transmit, Caps Lock

    The function of “Caps Lock Control” and “Key Pad Emulation” are only available for IBM PC/AT, PS/VP, PS/2 series personal computers and compatible machines. While selecting the other host interfaces, these selections don’t perform the above functions. 8017159/2014-04-24 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 34: Delay Settings

    Interfunction Delay: is a time delay of between transmission and reception of each segment of the message string. Intermessage, Intercharacter and Interfunction Delay are not available for IDM Bluetooth scanners working in SPP or HID mode. © SICK AG · Germany · All rights reserved · Subject to change without notice 8017159/2014-04-24...
  • Page 35: Function Key & Key Pad Emulation, Upper/Lower Case

    Inverse case (change all characters output to inverse case) Upper case (force all characters output as upper case) Lower case (force all characters output as lower case) 8017159/2014-04-24 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 36: Serial Interface Control

    Symbol ID Data Symbol ID Suffix 1-15 1 or 3 Variable 1 or 3 1-15 character characters digits characters length characters characters character character © SICK AG · Germany · All rights reserved · Subject to change without notice 8017159/2014-04-24...
  • Page 37: Delay Settings

    Interfunction Delay: is a time delay of between transmission and reception of each segment of the message string. Intermessage, Intercharacter and Interfunction Delay are not available for IDM Bluetooth scanners working in SPP or HID mode. 8017159/2014-04-24 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 38: Handshaking Protocol, Ack/ Nak

    NAKs from the host within the pre-set serial response time-out. This function is not available for batch mode. When you enable this function in on-line mode, the out-of-range function will be disabled automatically. © SICK AG · Germany · All rights reserved · Subject to change without notice 8017159/2014-04-24...
  • Page 39: Response Time-Out, Baud Rate

    The Serial Response Time-out is a pre-defined delay time for the Hand-held scanner to wait for handshaking, acknowledgment or non-acknowledgment from the host computer 8017159/2014-04-24 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 40: Data Frame

    7, Even, 1 7, Space, 1 7, Mark, 1 7, None, 2 7, Odd, 2 7, Even, 2 7, Space, 2 7, Mark, 2 © SICK AG · Germany · All rights reserved · Subject to change without notice 8017159/2014-04-24...
  • Page 41: Wand/ Laser Emulation Control (Idm1Xx Series)

    Code 39 symbology set will be skipped. Code 39 Replace Any character not normally available in the standard Code 39 symbology set will be translated as Space. 8017159/2014-04-24 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 42: Symbology Reading Control

    PDF417/Micro PDF417 (default=V) (1 character) Codablock F (default=Y) (1 character) Code 16K (default=Q) (1 character) Code 49 (default=U) (1 character) Korea Post Code (default=a) (1 character) © SICK AG · Germany · All rights reserved · Subject to change without notice 8017159/2014-04-24...
  • Page 43: Symbology Id Transmission

    Enable both prefix and suffix SICK symbology ID transmission Enable prefix AIM symbology ID transmission Enable suffix AIM symbology ID transmission Enable both prefix and suffix AIM symbology ID transmission 8017159/2014-04-24 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 44: Readable Bar Codes

    Code 11 MSI/Plessey UK/Plessey Telepen GS1 DataBar (RSS-14) * IATA Coupon Code PDF417 * /Micro PDF417 Codablock F Code 16K Code 49 Korea Post Code © SICK AG · Germany · All rights reserved · Subject to change without notice 8017159/2014-04-24...
  • Page 45 *. When you set the minimum and maximum length of each symbology, please note the data length of the scanned bar code doesn’t include start/stop characters. 8017159/2014-04-24 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 46: Code 39/ Code 32

    Scan 2 digits from the option code chart in the Appendix; then the scanner will terminate this selection automatically. Trioptic Code 39 and Code 39 Full ASCII cannot be enabled simultaneously. © SICK AG · Germany · All rights reserved · Subject to change without notice 8017159/2014-04-24...
  • Page 47: Code 39

    Level 3: If you failed to read poorly-printed or out-of-spec. bar codes in level 2, please select level 3. This is the most aggressive setting and may increase the misread. 8017159/2014-04-24 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 48: Codabar/ Nw-7

    Codabar Max. Length 01-98 (2 digits) Scan 2 digits from the option code chart in the Appendix; then the scanner will terminate this selection automatically. © SICK AG · Germany · All rights reserved · Subject to change without notice 8017159/2014-04-24...
  • Page 49: Upc-A/ Upc-E

    Disable WPC Selection Basic With 2-digit With 5-digit Enable Enable Check Numeric (UPC/EAN/CAN) Length Addendum Addendum Standardization Expansion Digit System UPC-A UPC-E EAN-13 EAN-8 8017159/2014-04-24 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 50 Level 1: This is the default setting which allows the scanner to operate fastest, while providing sufficient security in decoding “in-spec” UPC/EAN bar codes. © SICK AG · Germany · All rights reserved · Subject to change without notice 8017159/2014-04-24...
  • Page 51 UPC/EAN with only 5 supplement digits or UPC/EAN with 2/5 supplement digits. The default value is Level 3. When you select a higher level, it may impact the reading speed on poorly-printed, low contrast or damaged barcode labels. 8017159/2014-04-24 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 52: Ean Code

    Level 2 Level 3  Level 4 Level 5 Level 6 Level 7 Level 8 Level 9 Level 10 Level 11 Level 12 Level 13 © SICK AG · Germany · All rights reserved · Subject to change without notice 8017159/2014-04-24...
  • Page 53 EAN with 2, or 5, or 2/5 supplement digits bar codes starting with specific prefix. The EAN without supplement digit will be transmitted. 8017159/2014-04-24 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 54: Ucc Coupon Extended Code

    “5”, EAN-13 barcodes starting with digit “99” and GS1-128 Coupon Codes. UPC-A, EAN-13 and EAN-128 must be enabled to scan all types of Coupon Codes. © SICK AG · Germany · All rights reserved · Subject to change without notice 8017159/2014-04-24...
  • Page 55: Iata & Interleaved 2 Of 5

    Select German Postal Code as primary format No check character  Validate USS check digit Validate OPCC check digit Disable check digit transmission  Enable check digit transmission 8017159/2014-04-24 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 56: Code 25 Family

    To decode all types of Code 25 or to variable length of Code 25 will increase the possibility of reading error. © SICK AG · Germany · All rights reserved · Subject to change without notice 8017159/2014-04-24...
  • Page 57: Code 11 & Code 93

    Code 39 Max. Length 01-98 (2 digits) Scan 2 digits from the option code chart in the Appendix; then the scanner will terminate this selection automatically. 8017159/2014-04-24 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 58: Msi/ Plessey

    MSI/ Plessey Max. Length 01-98 (2 digits) Scan 2 digits from the option code chart in the Appendix; then the scanner will terminate this selection automatically. © SICK AG · Germany · All rights reserved · Subject to change without notice 8017159/2014-04-24...
  • Page 59: Code 128

    Level 1: This is the default setting which allows the scanner to operate fastest, while providing sufficient security in decoding "in-spec." Code 128 bar codes. 8017159/2014-04-24 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 60: Gs1-128

    If data was completely un-match, output original data  For the Application Identifier (AI) table see chapter 5.6 on page 103 For the GS1-128 ASCII table see chapter 5.5 on page 100 © SICK AG · Germany · All rights reserved · Subject to change without notice 8017159/2014-04-24...
  • Page 61 GS1-128 special function list Scanning this barcode shows the GS1-128 special function settings. For the GS1-128 ASCII table see chapter 5.5 on page 100 8017159/2014-04-24 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 62: Plessey

    UK/ Plessey Max. Length 01-98 (2 digits) Scan 2 digits from the option code chart in the Appendix; then the scanner will terminate this selection automatically. © SICK AG · Germany · All rights reserved · Subject to change without notice 8017159/2014-04-24...
  • Page 63: Telepen

    Telepen Max. Length 01-98 (2 digits) Scan 2 digits from the option code chart in the Appendix; then the scanner will terminate this selection automatically. 8017159/2014-04-24 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 64: Gs1 Databar

    Only available for Expanded GS1 DataBar. Scan 2 digits from the option code chart in the Appendix; then the scanner will terminate this selection automatically. © SICK AG · Germany · All rights reserved · Subject to change without notice 8017159/2014-04-24...
  • Page 65: Composite Codes, Codablock F, Pdf417, Micro Pdf417

    UPC barcodes are only transmitted when the Micro PDF417 is detected. Disable  Codablock F Settings Enable Disable PDF417 PDF417/ Micro PDF417 Settings Enable PDF417  Disable MicroPDF417  Enable MicroPDF417 8017159/2014-04-24 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 66: Code 16K & Code 49

    Code 49 Max. Length 01-81 (2 digits) Scan 2 digits from the option code chart in the Appendix; then the scanner will terminate this selection automatically. © SICK AG · Germany · All rights reserved · Subject to change without notice 8017159/2014-04-24...
  • Page 67: Qr Code

    QR Code Max. Length 0001-7089 (4 digits) Scan 4 digits from the option code chart in the Appendix; then the scanner will terminate this selection automatically. 8017159/2014-04-24 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 68: Data Matrix

    Data Matrix Max. Length 0001-3116 (4 digits) Scan 4 digits from the option code chart in the Appendix; then the scanner will terminate this selection automatically. © SICK AG · Germany · All rights reserved · Subject to change without notice 8017159/2014-04-24...
  • Page 69: Aztec Code

    Aztec Code Max. Length 0001-3832 (4 digits) Scan 4 digits from the option code chart in the Appendix; then the scanner will terminate this selection automatically. 8017159/2014-04-24 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 70: Autralian Post, Us Planet, Us Postnet, British Post, Japan Post

    Australian Post Setting Auto-discriminate output option increases the risk of misread because the encoded data format does not specify the encoding table used for encoding. © SICK AG · Germany · All rights reserved · Subject to change without notice 8017159/2014-04-24...
  • Page 71: Netherland Kix Code, Intelligent Mail & Korea Post Code

    (USPS 4CB/ One Code) Enable Intelligent Mail Disable Korea Post Code  Korea Post Code Settings Enable Korea Post Code Length fixed in 6 characters. 8017159/2014-04-24 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 72: Dpm Code

    IDM Bluetooth scanners: if you take out the battery the DPM functionality will be disabled automatically. If you disable the DPM functionality the performance of reading printed 1D and 2D codes will be improved. © SICK AG · Germany · All rights reserved · Subject to change without notice 8017159/2014-04-24...
  • Page 73: Operation Mode

    “Light Source on Time” is reset. For you do not have to press the trigger frequently it is very convenient for multiple scanning. 8017159/2014-04-24 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 74: Bluetooth Scanners (Idmxx1 Series)

    3.8.2 Bluetooth scanners (IDMxx1 series) PROGRAM F_DEFAULT Family Code Selection P.C. Parameter Selection Option Code Trigger mode  Operation Mode Presentation mode © SICK AG · Germany · All rights reserved · Subject to change without notice 8017159/2014-04-24...
  • Page 75: Operation Control

    LED flash IDM120 series doesn’t support this function. Disable Good Read Indicator Enable  Disable Vibrator Control Enable  Only available for industrial series (IDMx6x). 8017159/2014-04-24 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 76: Dollar Sign, Redundancy, 1D Code Inverse Reading

    The Redundancy is the number of times the same barcode has to be decoded before it is transmitted. (To prevent potential misreading.) Disable  1D Barcode Inverse Reading Enable © SICK AG · Germany · All rights reserved · Subject to change without notice 8017159/2014-04-24...
  • Page 77: Reread Delay, Good Read Delay Control

    IDM2x0: The Reread Delay function is only available in Multiple Read mode or when using the Hands- free stand. Good Read Delay This Good Read Delay is the minimum amount of time before the Hand-held scanner can read another barcode. 8017159/2014-04-24 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 78: Light Source On Time, Hands Free Time-Out

    This function sets the time for the scanner to enter low power mode after any scanning activity. For corded scanners this setting is only available if the scanner is in low power mode. © SICK AG · Germany · All rights reserved · Subject to change without notice 8017159/2014-04-24...
  • Page 79: Presentation Auto-Sense, Sensitivity

    The presentation sensitivity is used to configure the sensitivity level when the scanner is set as presentation mode. The higher lever means higher sensitivity for detecting the barcode. 8017159/2014-04-24 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 80: Presentation Control, Scan Rate, Flash Duty

    But this may impact to the reading distance. Flash Duty Cycle The Flash Duty Cycle is designed to control the flashing frequency of the light source. © SICK AG · Germany · All rights reserved · Subject to change without notice 8017159/2014-04-24...
  • Page 81: Illumination Control, Presentation Background Lighting

    LED illumination at a dim level. This is helpful to detect the motion of scene. 8017159/2014-04-24 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 82: Aiming, Delay Aiming Time-Out, Decode Aiming

    For IDM260, this function is not supported in Hands-Free mode. Hand-Held mode: Low power, Trigger, Alternative, Toggle, Level & Multiple read mode Hands-Free mode: Presentation mode, Force mode, Diagnostic mode © SICK AG · Germany · All rights reserved · Subject to change without notice 8017159/2014-04-24...
  • Page 83: Center Alignment, Unique Barcode Reporting

    Hand-Held mode: Low power mode, Trigger mode, Alternative mode, Toggle mode, Level mode, Multiple read mode Hands-Free mode: Presentation mode, Force mode, Diagnostic mode 8017159/2014-04-24 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 84: Barcode Reading Direction

    Disable  1D Barcode Direction Indication Enable prefix direction mark transmission Transmission Enable suffix direction mark transmission Enable both prefix and suffix direction mark transmission © SICK AG · Germany · All rights reserved · Subject to change without notice 8017159/2014-04-24...
  • Page 85: Bluetooth Operation Control (Idm Bluetooth Series)

    Link Supervision Time-out This is a pre-defined radio link supervision timeout setting. The scanner will supervise the radio link status every preset seconds. 8017159/2014-04-24 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 86: Sleep Time-Out, Power Off Time-Out

    If you would like to wake up the scanner press the trigger button. Meanwhile you can disable this function by setting the time-out duration to “0”. © SICK AG · Germany · All rights reserved · Subject to change without notice 8017159/2014-04-24...
  • Page 87: Bluetooth Batch Scanning

    Please note that if “Radio disable” is selected, the radio link will be disconnected once you enter batch scanning. The radio link will be resumed when you transmit the stored data or exit batch scanning. 8017159/2014-04-24 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 88 In PICO mode up to seven scanners can be connected to one smart cradle. The Data Transmission Format helps to identify the source of the transmitted data. Example format: <MAC address><Field delimiter><Data> or <ID><Field delimiter><Data>. © SICK AG · Germany · All rights reserved · Subject to change without notice 8017159/2014-04-24...
  • Page 89: Bluetooth Device Name, Security Settings

    8017159/2014-04-24 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 90: Hid Link Quality, Power Saving Mode

    You can enable this function to prevent such errors. Bluetooth Power Saving Mode The Bluetooth scanner will enter low power consumption mode when you enable this function. © SICK AG · Germany · All rights reserved · Subject to change without notice 8017159/2014-04-24...
  • Page 91: Batch Reading (Idm2Xx Series)

    [SICK ID Hex value] • Length: 2 byte You can find the SICK ID hex value in the Symbology ID Table in the appendix on page 105. 8017159/2014-04-24 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 92 Start character that must match for Code 39, 42h = “B”, 43h = “C” End of second code Code identifier of Code 93 9999 Code length that must match for Code 93, 9999 = all lengths © SICK AG · Germany · All rights reserved · Subject to change without notice 8017159/2014-04-24...
  • Page 93 AIM Symbol interface) Length DataWizard interface) 1 character 1-15 1 or 3 Variable length 1 or 3 1-15 1 character characters digits characters characters characters 8017159/2014-04-24 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 94: Condensed Data Wizard

    Enable suffix AIM symbology ID transmission Enable both prefix and suffix AIM symbology ID transmission The IDM Set Up Tool can be downloaded on www.mysick.com. © SICK AG · Germany · All rights reserved · Subject to change without notice 8017159/2014-04-24...
  • Page 95: Data Formatter

    100 for details. All “Character” input should be referred to the ASCII/HEX Table listed in the Appendix (page 107) to find matched HEX value. 8017159/2014-04-24 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 96: Data Verifier

    Define position (refer 1 character to chapter 3.12.7) Disable  3rd identified character Enable Position: (2 digits) [00-7F] Define position (refer 1 character to chapter 3.12.7) © SICK AG · Germany · All rights reserved · Subject to change without notice 8017159/2014-04-24...
  • Page 97: Data Replacer

    Define position (refer 1 character to chapter 3.12.7) Disable  3rd Replacement Enable Position: (2 digits) [00-7F] Define position (refer 1 character to chapter 3.12.7) 8017159/2014-04-24 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 98: Data Organizer

    Define direction to chapter 3.12.7) Transmitted data excluded the data Include/ Exclude Control of identified position  Transmitted data included the data of identified position © SICK AG · Germany · All rights reserved · Subject to change without notice 8017159/2014-04-24...
  • Page 99: Select Barcode Symbology

    Data Matrix Chinese Sensible Code Postal Codes Korea Post Code Intelligent Mail barcode Planet Post Australian Post Japanese Post Postnet British Post KIX Post 8017159/2014-04-24 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 100: Position Calculation

    Scan “Identified Data Length” and set the length to “16”. • Scan “1st Identified Character” and set the identified position to “00”, then set the identified character to “39” (Hex Code of 9). © SICK AG · Germany · All rights reserved · Subject to change without notice 8017159/2014-04-24...
  • Page 101 Therefore when you set the identified position in the Data organizer, you must consider the inserted data which you already set via Data Formatter. 8017159/2014-04-24 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 102: Idm Set Up Tool

    9. To re-connect scanner and base station, scan the “pair mode”- code and place the scanner in the base station. Make sure that the USB Com Port driver is installed © SICK AG · Germany · All rights reserved · Subject to change without notice 8017159/2014-04-24...
  • Page 103: Firmware Upgrade Via Idm Set Up Tool

    7. Choose the correct firmware and click on “OK“. 8. Choose the right Communication Port (COM Port) and click on “Upgrade”. 9. Wait until the firmware upgrade was completed successfully: 8017159/2014-04-24 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 104: Idm Bluetooth Cradle

    15. Once you have finished upgrading the scanner, scan the “Pair Mode” code and place the scanner back into the cradle to reconnect the scanner to the base: Pair Mode © SICK AG · Germany · All rights reserved · Subject to change without notice 8017159/2014-04-24...
  • Page 105: Appendix

    PDF417/ Micro PDF417 17/ 25 Codablock Codablock F Korea Post Korea Post Code Remark: Above examples are given for the transmission of AIM ID. 8017159/2014-04-24 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 106: Symbology Id Table (2D And Post Codes)

    Table which is for IBM PC/XT/AT, PS/2, PS/VP, COMPAQ PC, HP Vectra PC, Notebook PC, APPLE and PowerMac, and WYSE PC Enhanced or fully compatible machines. The last character in the Ctrl output column varies for different countries. © SICK AG · Germany · All rights reserved · Subject to change without notice 8017159/2014-04-24...
  • Page 107: Ascii Input Shortcut (Reference Table)

    Scan the system command – FIN (Finish) to terminate Preamble setting. • Scan the system command – End to exit the programming mode for normal operation. 8017159/2014-04-24 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 108: Gs1-128 Ascii Table

    Ctrl + M Ctrl + N " " Ctrl + O Ctrl + P Ctrl + Q Ctrl + R & & Ctrl + S © SICK AG · Germany · All rights reserved · Subject to change without notice 8017159/2014-04-24...
  • Page 109 GS1-128 ASCII Table Operating Instructions IDM corded & IDM Bluetooth < < > > 8017159/2014-04-24 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 110 →(Right Arrow) “Shift +”, “Ctrl +” and “Alt +”: Read the direct input menu barcode twice when you output only Shift, Ctrl and Alt. © SICK AG · Germany · All rights reserved · Subject to change without notice 8017159/2014-04-24...
  • Page 111: Application Identifier Table

    351D Unnecessary 330D Unnecessary 352D Unnecessary 331D Unnecessary 353D Unnecessary 332D Unnecessary 354D Unnecessary 333D Unnecessary 355D Unnecessary 334D Unnecessary 356D Unnecessary 335D Unnecessary 8017159/2014-04-24 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 112 Unnecessary 8003 Indispensability (FNC1) Unnecessary 8004 Indispensability (FNC1) Unnecessary 8005 Indispensability (FNC1) Indispensability (FNC1) 8006 Indispensability (FNC1) Indispensability (FNC1) Indispensability (FNC1) 8007 Indispensability (FNC1) © SICK AG · Germany · All rights reserved · Subject to change without notice 8017159/2014-04-24...
  • Page 113 8020 Indispensability (FNC1) Indispensability (FNC1) 8100 Indispensability (FNC1) Indispensability (FNC1) 8101 Indispensability (FNC1) Indispensability (FNC1) 8102 Indispensability (FNC1) Indispensability (FNC1) Indispensability (FNC1) Indispensability (FNC1) 8017159/2014-04-24 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 114: Host Interface Quick Set

    USB HID Turbo Mode PS/2 (DOS/V) Keyboard Replacement For IDM Bluetooth scanners the above host interface quick commands are only available when working with a smart cradle. © SICK AG · Germany · All rights reserved · Subject to change without notice 8017159/2014-04-24...
  • Page 115: Operation Mode Quick Set

    Alternative (Periodic Power off) Trigger (External Triggering) Toggle (Repeat reading)  Flash (Pulse driven reading) Presentation (Auto Sensing) Diagnostic (Test reading) Level (Auto power off) 8017159/2014-04-24 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 116: Corded Scanners (Idm2X0 Series)

    Trigger (External Triggering) Toggle (Repeat reading)  Level (Auto power off) Presentation (Auto Sensing) Diagnostic (Test reading) Multiple Read 5.8.3 Bluetooth Scanners Trigger Mode Presentation Mode © SICK AG · Germany · All rights reserved · Subject to change without notice 8017159/2014-04-24...
  • Page 117: Link Mode Quick Set

    The Link Mode commands are only relevant for IDM Bluetooth scanners. PAIR Mode PICO Mode Uninstall SSP Master SSP Slave HID Mode HID Legacy Mode HID Mode with Passkey 8017159/2014-04-24 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 118: System Commands

    User Default: After scanning “Save User Default” command, all current parameters will be stored to the flash memory. Once you change the parameter and would like to return to previous setting, please scan “User Default”. © SICK AG · Germany · All rights reserved · Subject to change without notice 8017159/2014-04-24...
  • Page 119 System Commands Operating Instructions IDM corded & IDM Bluetooth Additional System Commands for IDM Bluetooth Scanners Sleep Save Configuration Power Off Paging Clone 8017159/2014-04-24 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 120: Option Codes

    Option Codes Operating Instructions IDM corded & IDM Bluetooth 5.11 Option Codes Abort END (Exit) FIN (Finish) © SICK AG · Germany · All rights reserved · Subject to change without notice 8017159/2014-04-24...
  • Page 121 Option Codes Operating Instructions IDM corded & IDM Bluetooth 8017159/2014-04-24 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 122 E-Mail support@sick.jp 1 (800) 325-7425 – tollfree Magyarország E-Mail info@sickusa.com Phone +36 1 371 2680 E-Mail office@sick.hu Nederland Phone +31 (0)30 229 25 44 More representatives and agencies E-Mail info@sick.nl at www.sick.com SICK AG | Waldkirch | Germany | www.sick.com...