Divar XF
Alarm recording at input - displays which inputs are in alarm recording mode
Motion recording at input - displays which inputs are in motion recording mode
Current recording status - displays video and audio recording status and mode for each input
Sensors
Displays actual temperature and voltage sensor values. If temperature levels are outside of
the normal range, the displayed values are yellow. If this occurs, check that the ambient
temperature is within the recommended specifications and that there is proper air ventilation.
If the temperature reaches a critical level, the unit automatically shuts down. To restart the
unit, disconnect the power cord, wait for at least 30 seconds, and then reconnect the power
cord.
Sensor name
Processor
Air inlet
Air outlet
Hard disk #1
Hard disk #2
Hard disk #3
Hard disk #4
Table 5.1 Temperature sensors
Voltage level
12 Volt
5 Volt
3.3 Volt
Table 5.2 Power supply levels
5.9.2

Logbook

The logbook menu is used to display a filtered history of system events.
Logbook filter
Set various filter criteria to search in a specified time period for various system events.
Bosch Security Systems
Lower limit
5 °C / 41 °F
5 °C / 41 °F
5 °C / 41 °F
5 °C / 41 °F
5 °C / 41 °F
5 °C / 41 °F
5 °C / 41 °F
Lower limit
10.8 V
4.7 V
3.1 V
Installation manual
Operating instructions | en
Upper limit
100 °C / 212 °F
45 °C / 113 °F
55 °C / 131 °F
55 °C / 131 °F
55 °C / 131 °F
55 °C / 131 °F
55 °C / 131 °F
Upper limit
13.2 V
5.3 V
3.5 V
F.01U.135.429 | 2.5 | 2009.08