Functional safety dual input smart hart temperature transmitter (146 pages)
Summary of Contents for Moore Industries TDZ
Page 1
& April 2016 Smart HART Temperature 235-745-00 F Transmitters & Displays All product names are registered trademarks of their respective companies.
Page 2
The THZ and TDZ Intelligent PC Configuration Software is equipped with our new HelpMap Navigation System. This searchable, comprehensive help system includes all the tables and illustrations you will need to easily setup your unit–from startup to hookup. Reference the HelpMap if you are looking for more detailed information than is provided in this manual.
Dimensions ......................... 5-9 Configuring a THZ or TDZ ................9 Installing the Configuration Software ............... 10 Connecting the THZ or TDZ to the PC ............... 10 Necessary Equipment Table ..................10 Using the PC Configuration Program ............11 Using the HART Communicator ..............13 Programming when a Device Description is Available ...........
Note - Information that is helpful for a procedure, condition, or operation of the unit. Figure 1. The THZ and TDZ Smart HART Temperature Transmitters’ remotely programmable input and combination analog/digital output make it the perfect answer to problems encountered when interfacing control room equipment and field sensors.
500 msec typical from the background; Bottom Row, Weight THZ DIN: 221 grams (7.9 oz) time an input is applied to the 10mm (0.4 inch) high digits THZ HPP: 101 grams (3.6 oz) output reaching 90% of its on a reflective background;...
THZ & TDZ Table 1. Input Types, Ranges, Minimum Span and Maximum Range Specifications, and Accuracy of the THZ and TDZ α α α α α Ω Ω Ω Ω Ω Conformance Minimum Input Maximum Sensor-to- Input Type Range Span...
NPT process–black metal cover CH6 Polypropylene connector head DH THZ [DH] replacement transmitter with no enclosure (DH Housing) DH2NG THZ [DH] enclosed in a 2-Hub, dual-compartment enclosure with two, Dual- ½-inch NPT entry ports and a glass cover Compartment DH2TG THZ [DH] enclosed in a 2-Hub, dual-compartment enclosure with two, Smart HART ¾-inch NPT entry ports and a glass cover...
THZ [DH] Ambient Effects Table Table 3. THZ [DIN], [HPP], and TDZ Ambient Effects Table THZ [DH] Ambient Temperature Effects TDZ [HP], THZ [DIN] & THZ [HPP] Ambient Temperature Effects Sensor Digital Accuracy per 1°C Analog Accuracy per 1°C Sensor Digital Accuracy per 1°C...
Page 11
TRANSMITTER 80mm (3.15 in) +PS –PS 110mm 25mm (4.33 in) 113mm (1.0 in) (4.45 in) Figure 6. LH Housing Dimensions (For use with the THZ HPP) 87mm 51mm Safety Lock (3.43 in) (2.01 in) (LH2 only) Metal Tag Conduit 61mm Entry Port (2.40 in)
Page 12
THZ & TDZ Figure 7. THZ Dual Compartment (DH Enclosure) Dimensions. CONDUIT PORTS CONNECTIONS DISPLAY ENTER BEHIND THE (METAL COVER) (GLASS UNIT TO PROTECT THE COVER) THZ [DH] DISPLAY FROM HUMIDITY COVERS AT EACH END OF THE THZ [DH] PROVIDE EASY ACCESS...
HART modem connection to the PC’s serial port. command bar to start this advanced help tool . You can configure the THZ or TDZ with either a standard HART Communicator or our PC software. Figure 10 and Table 5 provide the information you need to configure your unit.
Insert the diskette labeled “TDZ/THZ The THZ or TDZ must be connected to the PC in or- Configuration Program Installation Disk 1 of 3” der to: trim input, trim output, assign a tag, perform a into the floppy drive of the PC.
THZ & TDZ Figure 9. Most of the THZ or TDZ Operating Parameters can be set from the Main Screen of the Configuration Program. Using the PC Program 4. Variables–Watch this section to track all the Once the default configuration has been saved to information that your transmitter is monitoring.
Page 16
THZ & TDZ CURRENT Figure 10. Using a HART Communicator or the PC to configure the THZ or TDZ. METER – LOAD=250 OHMS 12-24Vdc POWER THZ OR TDZ (THZ HPP SHOWN) – NOTE: WHILE THE THZ HART MODEM DIN & DH UNITS AND TDZ –PS...
Using the HART Communicator Programming when a Device Description is Available The THZ and TDZ can be programmed using a HART Communicator. If your communicator is equipped With the transmitter connected as illustrated in with the Device Description (DD) for your transmit- Figure 10, apply power and turn the communicator ter, the following section, “The HART Communicator...
Page 18
THZ & TDZ Figure 11. Summarizing the THZ and TDZ Configuration Menus in a HART Communicator ONLINE MENU CONFIGURE SENSOR 1 PT3850 100 DEVICE SETUP 1 MODEL 1 SENSOR TYPE SENSOR TYPE 2 PT3850 200 2 DEVICE SETUP 2 OUT DAMP PROCESS VARIABLE 3 PT3850 300...
Loop Test. average over a user-programmed time period, and us- ing this value for the THZ or TDZ output. The damp- ing time can be set between 0 and 30 seconds. G. Trimming the Input Sensor From the “Sensor Trim”...
Page 20
THZ & TDZ Figure 12. Generic Menu Overview ONLINE GENERIC PROCESS VARIABLE DEVICE SETUP 1 SNSR 1 DEVICE SETUP 1 PROCESS VARIABLES 2 AI % 2 PV 3 A01 DISPLAY 3 PV AO DIAG/SERVICE 4 PV LRV 2 DIAG/SERVICE 1 TEST DEVICE...
Values The initial screen, the “Online Generic” menu, If the polling address is set to 0, the THZ or TDZ is displays the process value, analog output, and the automatically set to analog mode. Multiple units on programmed upper and lower parameters of the the same bus must have different addresses.
CE certification must adhere to the guide- and THZ diagnostic data. The address is also used to lines above in order to meet the requirements set forth locate the appropriate THZ or TDZ, to initiate configu- in applicable EMC directives (EN55011, EN 50082-1, ration, and to calibrate.
To implement two-way communication between the and services. We perform a battery of stringent qual- THZ and the device being used to configure it or re- ity assurance checks on every unit we ship. If any ceive its information, the THZ or TDZ operates in a Moore Industries product fails to perform up to rated HART Master/Slave structure.
THZ & TDZ First, verify that you have a copy of Internet Ex- Troubleshooting the PC Software plorer, then check the version by going to the “Help” With the large variety of PC manufacturers that exist and “About Internet Explorer” menu in Internet Ex- today, there is always the small chance that a par- plorer program.
This appendix contains the installation diagram for the are to operate in areas requiring intrinsically safe in- THZ & TDZ carrying the intrinsically safe option. It strumentation. also includes guidelines for setting up zener barriers necessary in these types of applications.
Page 26
THZ & TDZ The Interface Solution Experts...
Page 27
THZ & TDZ The Interface Solution Experts...
Page 28
THZ & TDZ The Interface Solution Experts...
Page 29
Equipment Ratings longer than 2 inches. The THZ and TDZ do not generate hazardous volt- ages, rather, they accommodate a temperature in- put, and generates a low voltage current output. Products connected to the THZ or TDZ should be CE Certification-related Guidelines designed to receive these inputs.
Page 30
4. Ship the equipment to the Moore Industries location nearest you. The returned equipment will be inspected and tested at the factory. A Moore Industries representative will contact the person designated on your documentation if more information is needed. The repaired equipment, or its replacement, will be returned to you in accordance with the shipping instructions furnished in your documentation.
Page 31
User’s Manual—Complete information for an individual and other related areas, the approval classifications are instrument model can be found in the Moore Industries stated on the externally mounted metal ID Tag to be FM User’s Manual for that instrument. The manual provides approved as Explosion-Proof for Class I, Division 1, information for putting the instrument safely into service.
Page 32
The following ground wiring practices must be followed to ensure proper performance of the Moore Industries 2-INCH PIPE MOUNTING HARDWARE instrument in any application. 84mm • Any Moore Industries product in a metal case or (3.30 in) 2-in Pipe Bracket housing must be grounded. Mounting Holes (4) •...
Need help?
Do you have a question about the TDZ and is the answer not in the manual?