IMPORTANT INFORMATION FOLLOWING AN
ALARM
If the alarm indicates a gas leak or you can smell gas:
g
DANGER OF EXPLOSION!
• Extinguish all open flames, embers and burning tobacco !
• Do not under any circumstances switch electrical devices on or off !
• Do not disconnect any electric plugs (including that of the alarm unit)!
• Warn any persons at risk in the danger zone.
• Shut off the gas supply at the gas tap.
• Air all affected rooms.
• Deal with the cause with a qualified/authorized expert.
Replace after 5 years use.
Installation date :
(Please display this page in a visible position next to the gas alarm)
GAS ALARM
Ga 617
h
c
Gas alarm
Operation and Safety Notes
Introduction ................................................................................................... Page
Proper use ..................................................................................................... Page
Pack contents ................................................................................................ Page
Features ........................................................................................................ Page
Technical data................................................................................................ Page
Safety instructions ......................................................................................... Page
Initial operation .............................................................................................. Page
Power supply ................................................................................................. Page
Installation ..................................................................................................... Page
Operation ....................................................................................................... Page
Function test .................................................................................................. Page
Fault indicator ............................................................................................... Page
Troubleshooting ............................................................................................. Page
Maintenance and cleaning ............................................................................. Page
Disposal......................................................................................................... Page
Warranty ........................................................................................................ Page
Service .......................................................................................................... Page
Declaration of conformity ............................................................................... Page
4
4
4
4
5
5
8
9
10
10
11
11
12
13
13
13
14
14
2

Advertisement

Table of Contents
loading

Summary of Contents for DEXAPLAN GA 617 - 11-2007

  • Page 1: Table Of Contents

    GAS ALARM Gas alarm GA 617 IMPORTANT INFORMATION FOLLOWING AN Introduction ....................Page Proper use ..................... Page ALARM Ga 617 Pack contents ....................Page Features ......................Page If the alarm indicates a gas leak or you can smell gas: Technical data....................Page Safety instructions ..................
  • Page 2: Introduction

    Introduction age caused by improper use or incorrect oper- Please read these operating instructions thor- ation of the device. Before initial operation, oughly and carefully. They are part of this please read all operating instructions carefully product and contain important instructions and refer to the page showing the illustrations.
  • Page 3: Technical Data

    On the rear of the casing (see Fig. B): Operating temperature: -10 °C to +40 °C Rear of casing Relative air humidity: max. 95 % Mounting fixture Material: ABS plastic 12 V DC terminal screws Dimensions: 35 x 85 x 85 m (h x w x l) Cable guide Weight: approx.
  • Page 4 Danger! Caution • Do not ignite any naked lights. Extinguish complete and undamaged. • Do not leave small children unsupervised any burning tobacco or candles etc. • If you are uncertain which type of gas you • The device must only be repaired by author- with the packaging material.
  • Page 5: Initial Operation

    o Directly next to an oven. 12 V DC mains adapter cent to the gas alarm and write on it the alarm being given only after a delay or not at all. o Directly above a washbasin or drain. o Lead the bare cable ends (approx. 8 mm) date you first used the alarm.
  • Page 6: Installation

    Fault indicator 12 V DC mains adapter Follow the instructions in the section a dual connection (parallel connection) is „What to do in the event of a gas leak“ made. Switching on: The device carries out a self-checking routine o Plug the mains adapter directly and fully for your safety.
  • Page 7: Troubleshooting

    Troubleshooting Maintenance and cleaning Warranty Danger: make sure that the gas alarm is This device has a warranty of 3 years from the not live when maintaining or cleaning the date of purchase. The device was manufac- Fault Cause Remedy device.
  • Page 8: Service

    Service Information on dealing with problems can be found under www.dexaplan.com. If you have any questions, please contact our service office by email (service@dexaplan.de) T 0870 241 3029 or by telephone ( T 1890 851 851; Monday - Friday between 08.30 and 17.00).

This manual is also suitable for:

Ga 617

Table of Contents