DEXAPLAN GA 607 - 8-2005 Operation And Safety Notes

Gas alarm with sensor for liquid gas (propane, butane) and town gas/natural gas (methane)

Advertisement

Quick Links

IB_GA607_UK_IRL_Cover.indd 1-3
IB_GA607_UK_IRL_Cover.indd 1-3
Gas alarm GA 607
with sensor for liquid gas (propane, butane)
and town gas/natural gas (methane)
Operation and safety notes
Dexaplan
Operation and safety notes
Page
5
20.09.2005 12:13:55 Uhr
20.09.2005 12:13:55 Uhr

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GA 607 - 8-2005 and is the answer not in the manual?

Questions and answers

Summary of Contents for DEXAPLAN GA 607 - 8-2005

  • Page 1 Dexaplan Gas alarm GA 607 with sensor for liquid gas (propane, butane) and town gas/natural gas (methane) Operation and safety notes Page Operation and safety notes IB_GA607_UK_IRL_Cover.indd 1-3 IB_GA607_UK_IRL_Cover.indd 1-3 20.09.2005 12:13:55 Uhr 20.09.2005 12:13:55 Uhr...
  • Page 2 EC Directives - Declaration of Conformity Dexaplan GmbH declare that the Product listed below is in conformity with the Directives, Standards and other Normative Directives listed below: 89/336/EEC Electromagnetic Compatibility Directive (EMC) 73/23/EEC Low Voltage Directive Product type: Gas Alarm, including 12 Volt Adapter...
  • Page 3: Table Of Contents

    Introduction ......................Page Proper use ....................... Page Pack contents ......................Page Features ........................Page Technical data ......................Page Safety instructions ....................Page Initial operation ......................Page Power supply ......................Page Installation ....................... Page Operation ........................ Page Function test ......................Page Troubleshooting .......................
  • Page 4: Introduction

    Introduction by improper use or incorrect operation of the Please read these operating instructions thor- device. Before initial operation, please read all oughly and carefully. They are part of this operating instructions carefully and refer to the product and contain important instructions page showing the illustrations.
  • Page 5: Technical Data

    Mounting fi xture Dimensions: 35 x 85 x 85 m (h x w x l) 12 V DC terminal screws Weight: approx. 100 g Cable guide Protection class: Side and lower sensor openings Mains adapter (delivered with the gas alarm): Technical data Power supply: 230 V ~ 50 HZ...
  • Page 6 • Do not leave children unsupervised with make sure that they evacuate the area to the device. Danger to life and risk of injury. safety. • Do not damage any gas, electricity or • Do not under any circumstances discon- telecommunication lines when fi...
  • Page 7 Before connecting a 12 V DC mains resulting from improper use and loss of adapter to the mains, make sure that the the warranty. mains current is 230 V ~ 50 Hz and • Position the device so that the sensors equipped with a max.
  • Page 8: Initial Operation

    Initial operation 12 V DC mains adapter is located max. 2 m Preparation and materials required: away from the installation position of the gas The stated materials are not included in the alarm. To detect town, natural and methane delivery scope. The information provided here gas, the installation position should be as far is non-binding and intended as a guide.
  • Page 9: Power Supply

    below –10° C or rise above +50°C or in Attach each cable end to a terminal screw which air humidity can rise above 95%. . The polarity is not important for this Areas in which dust or dirt can clog the connection.
  • Page 10: Installation

    Installation green POWER LED then lights up to indi- Danger: make sure that the gas alarm is cate that the device is ready for operation (see not live during installation. Fig. A) Remove the mounting fi xture from the rear side of the casing (see Fig.
  • Page 11: Function Test

    The alarm continues until the gas concentra- directly next to the lower or side sensor tion falls back to below the pre-set sensitivity opening level. Make sure that there is no fl ame on the lighter. The gas alarm detects the gas Follow the instructions on to how to with the sensor.
  • Page 12: Disposal

    Fault Cause Remedy The gas alarm does not The power supply is faulty. Make sure that the power work. supply is free of faults. responded. clable packaging materials are selected for The alarm continues until the gas con- their ecologically compatible and disposable centration falls back to below the pre-set properties.
  • Page 13: Service

    Service Information on dealing with problems can be found under www.dexaplan.com. If you have any questions, please contact our service offi ce by email (service@dexaplan.de) ¬ 0870 241 3029 or by telephone ( Mo.-Fr. 08:30-17:00 ¬ 1890 851 851).
  • Page 14 Gas alarm GA 607 IMPORTANT INFORMATION FOLLOWING AN ALARM If the alarm indicates a gas leak or you can smell gas: DANGER OF EXPLOSION! • Extinguish all open fl ames, embers and burning tobacco ! • Do not under any circumstances switch electrical devices on or off ! •...