  • Page 1 Dexaplan GmbH Paul-Böhringer-Str. 3 · D-74229 Oedheim (Germany) Information last updated - Stav informácií - Stav informací: 08/2007 Ident.-No.: 08-2007-BA-611-GB/SK/CZ...
  • Page 2 ALARM AND EMERGENCY TELEPHONE DIALLER BA 611 ALARM AND EMERGENCY POPLAŠNÝ A NÚDZOVÝ POPLAŠNÉ A VOLICÍ ZAŘÍZENÍ V PŘÍPADĚ NOUZE/ TELEPHONE DIALLER VOLIACI PRÍSTROJ POPLAŠNÉ ZAŘÍZENÍ A VOLICÍ ZAŘÍZENÍ V NOUZOVÉM PŘÍPADĚ Operation and Safety Notes Pokyny pre obsluhu a bezpečnostné pokyny Pokyny pro obsluhu a bezpečnostní...
  • Page 3: Table Of Contents

    Content Introduction Proper use................ Page 4 Included items ..............Page 4 Features and equipment ..........Page 4 Technical information............Page 5 Safety advice ..............Page 5 Preparing for first use Plan where you are going to locate the device....Page 6 Telephone connection ............
  • Page 4 22 mm ca.40° 100° max. 90° 180° ca. 4 mm...
  • Page 5: Proper Use

    Internet a 1x Battery CN23 A, 12V alkaline Screw for connection compartment cover page at www.dexaplan.com or contact our service centre 1x Telephone cable adapter (only included in Screw holes for mounting (see the section about “Service”).
  • Page 7: Technical Information

    Introduction / Safety advice Technical information Remote control BA 611 R Danger! Operating voltage: Alarm unit BA 611 Current input: max. 25 mA connecting the 12 V DC adapter to the mains that the Operating voltage: Power supply: 1x battery 12V, alkaline electricity supply to the device is protected by the ap- Current input: 130mA (alarm), <...
  • Page 8: Preparing For First Use

    Telephone connection Observe the following points: Place the alarm unit near a mains outlet socket and Connect the supplied telephone connection cable an analogue telephone connection point. Take note between the telephone line connection “LINE” Attention! of the cable length required. and your analogue domestic telephone connection point.
  • Page 9: Making The Settings

    Mains adapter: Then press the OK key and after 10 seconds . A “P” appears on the LC display Connect the mains adapter to the mains adapter start from the beginning of this process again.) Continue entering the telephone number as in the connection socket (9V).
  • Page 10: Positioning The Alarm Unit

    Press the OK key Wait 10 seconds until the device automatically quits Wait 10 seconds until the device automatically the Wait 10 seconds until the device automatically quits the settings mode. settings mode. the settings mode. Setting the entry delay: Reset: Switching automatic dialling on / off: Here you can set the time you have, from the time any...
  • Page 11: Operation

    2. Positioning: (assuming that the memory location has been as- You can position the alarm unit upright or lying down. The word “ARM” disappears from the LC display signed a telephone number). If the surface is very smooth it is recommended that you of the alarm unit.
  • Page 12 As determined by the automatic dialling function Enter the current password. Switching the gong function on/off: (factory setting: dialling function switched on) and Press the OK key Set the gong On / Off switch on (setting “I”). the set number of dialling processes the alarm and If appropriate, the alarm sound stops.
  • Page 13: Changing Batteries

    Summary of the sounds Remote control handset function is switched on) or an alarm is trig- If the check LED is weak when the keys on the remote gered (in the armed state), however only after Sound Meaning control are operated and/or the range of the remote control the end of the exit delay;...
  • Page 14: Rectifying Faults

    Rectifying faults / Maintenance and cleaning Rectifying faults Fault Cause Remedy Fault Cause Remedy Fault Cause Remedy Motion detector Pets, air move- Change the Dialling function Set the dialling Your settings The settings Press the OK detects motion ments, direct position of the is switched off function on.
  • Page 15: Disposal

    Declaration of conformity dispose of your used batteries. Batteries must not be disposed of with the household refuse. Dexaplan GmbH hereby declares that the alarm and emergency telephone dialler complies with the basic Information requirements and the other relevant regulations of Directive 1999 / 5 / EC.
  • Page 23 Sicherheit / Bedienung...
  • Page 25 Sicherheit / Bedienung...