Technical information

Alarm unit BA 611
Operating voltage:
9V
Current input:
130mA (alarm), < 5mA (standby)
Power supply:
From the supplied mains
adapter or the backup battery
(9 volt block 6LR61,
not included)
Radio receiver:
433.92 MHz
Siren:
100 dB(A) +/- 5 dB(A) at 0.3 m
(mains operation)
Siren duration (max.):
Approx. 30sec./approx. 30sec.
pause / approx. 30 sec. alarm
Gong function:
Can be deactivated; signals
each detected motion with a
gong sound
Programmable
telephone numbers:
Max. 5 numbers
Automatic dialling:
Up to 5 times
Programmable code:
3 to 6 digits
Exit delay:
Approx. 55 sec.
Entry delay:
Programmable: 0/5/10/15/
20sec.
Operating temperature: 0 °C to + 39 °C
Area of use:
Interior rooms
Housing material:
ABS
Housing dimensions:
Approx. 86 x 150 x 46 mm
(W x H x D)
Weight:
Approx. 197 g (without battery,
without accessories)
Motion detector (attached to the alarm unit)
Sensor:
Passive infrared (PIR)
Detection angle:
Approx. 100 ° horizontal
Detection range:
Approx. 6 m at 20 °C (trans-
verse motion, mounting height
approx. 0.5 to 2 m)
Remote control BA 611 R
Operating voltage:
Current input:
DC
Power supply:
Transmission frequency: 433.92 MHz
Transmission range:
Coding:
Function indicator:
Operating temperature: 0 °C to + 40 °C
Housing material:
Housing dimensions:
Weight:
Mains adapter
Power supply:
Power consumption:
Output:

Safety advice

The following advice is intended for your safety and sat-
isfaction during operation of the device. Please note that
non-observation of this safety advice can lead to consid-
erable danger.
Explanation of the symbols and terms used:
Danger! Non-observance of this instruction or
advice could endanger life and health.
Attention! Non-observance of this instruction or
advice will endanger property.
Tip! Observance of this instruction or advice will
achieve best performance.
12V
DC
max. 25 mA
1x battery 12V, alkaline
(type CN 23 A)
Approx. 20 m (in open space)
Factory set unique code
LED
ABS
Approx. 45 x 67 x 16 mm
(W x H x D)
Approx. 34 g (with battery)
230V ~ AC, 50 Hz
4.5VA
9V
DC, max. 500 mA
Introduction / Safety advice
Danger!
before connecting the 12 V DC adapter to the mains
that the electricity supply to the device is protected
by the appropriate fuse or trip in accordance with
the applicable regulations. Do not connect any other
power supply to the connection terminals. Other-
someone is in its direct vicinity Otherwise there is a
water or telecoms when you are drilling or mounting
cables in such a position that they cannot be dam-
aged or become a trip hazard. Otherwise there is a
batteries can result in serious damage to health.
-
-
-