Technical Information; Safety Advice - DEXAPLAN BA 611 - 8-2007 Manual

Alarm and emergency telephone dialler
Table of Contents

Advertisement

Available languages

Available languages

Technical information

Alarm unit BA 611
Operating voltage:
9V
DC
Current input:
130mA (alarm), < 5mA (standby)
Power supply:
From the supplied mains
adapter or the backup battery
(9 volt block 6LR61,
not included)
Radio receiver:
433.92 MHz
Siren:
100 dB(A) +/- 5 dB(A) at 0.3 m
(mains operation)
Siren duration (max.):
Approx. 30sec./approx. 30sec.
pause / approx. 30 sec. alarm
Gong function:
Can be deactivated; signals
each detected motion with a
gong sound
Programmable
telephone numbers:
Max. 5 numbers
Automatic dialling:
Up to 5 times
Programmable code:
3 to 6 digits
Exit delay:
Approx. 55 sec.
Entry delay:
Programmable: 0/5/10/15/
20sec.
Operating temperature: 0 °C to + 39 °C
Area of use:
Interior rooms
Housing material:
ABS
Housing dimensions:
Approx. 86 x 150 x 46 mm
(W x H x D)
Weight:
Approx. 197 g (without battery,
without accessories)
Motion detector (attached to the alarm unit)
Sensor:
Passive infrared (PIR)
Detection angle:
Approx. 100 ° horizontal
Detection range:
Approx. 6 m at 20 °C (trans-
verse motion, mounting height
approx. 0.5 to 2 m)
Remote control BA 611 R
Operating voltage:
12V
Current input:
max. 25 mA
Power supply:
1x battery 12V, alkaline
(type CN 23 A)
Transmission frequency: 433.92 MHz
Transmission range:
Approx. 20 m (in open space)
Coding:
Factory set unique code
Function indicator:
LED
Operating temperature: 0 °C to + 40 °C
Housing material:
ABS
Housing dimensions:
Approx. 45 x 67 x 16 mm
(W x H x D)
Weight:
Approx. 34 g (with battery)
Mains adapter
Power supply:
230V ~ AC, 50 Hz
Power consumption:
4.5VA
Output:
9V

Safety advice

The following advice is intended for your safety and sat-
isfaction during operation of the device. Please note that
non-observation of this safety advice can lead to consid-
erable danger.
Explanation of the symbols and terms used:
Danger! Non-observance of this instruction or
advice could endanger life and health.
Attention! Non-observance of this instruction or
advice will endanger property.
Tip! Observance of this instruction or advice will
achieve best performance.
Danger!
DC
connecting the 12 V DC adapter to the mains that the
electricity supply to the device is protected by the
appropriate fuse or trip in accordance with the ap-
plicable regulations. Do not connect any other power
supply to the connection terminals. Otherwise there
someone is in its direct vicinity Otherwise there is a
DC, max. 500 mA
water or telecoms when you are drilling or mounting
cables in such a position that they cannot be dam-
aged or become a trip hazard. Otherwise there is a
batteries can result in serious damage to health.
Introduction / Safety advice
GB/IE
-
-
-
5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ba 611

Table of Contents