Advertisement

Shenzhen Growatt New Energy Technology CO.,LTD
Building B, Jiayu Industrial Park, #28, GuangHui Road,
Shiyan Street, Baoan District, Shenzhen, P.R.China
T
0755-29515888
F
0755-27472131
E
service@ginverter.com
W
www.ginverter.com
GR - UM - 033 - A - 04
Installation
&
Operation Manual
Growatt 750-S
Growatt 1000-S
Growatt 1500-S
Growatt 2000-S
Growatt 2500-S
Growatt 3000-S

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 2500-S and is the answer not in the manual?

Questions and answers

Summarization of Contents

About Manual
Validity
Defines the scope and applicability of the installation and user guide.
Target Group
Identifies qualified personnel for device construction and operation.
Additional Information
Provides resources for finding further information on special topics.
Safety
Intended Use
Specifies the function of converting DC to AC and rules for safe operation.
Qualification of Skilled Person
Outlines requirements for personnel installing and operating the grid-tied inverter.
Safety Instruction
Highlights essential precautions for installing and operating Growatt inverters safely.
Assembly Warnings
Details critical warnings regarding inspection, mounting, and potential hazards during assembly.
Electrical Connection Warnings
Covers dangers of live components, residual voltage, and proper handling of electrical connections.
Operation Warnings
Provides essential safety warnings for operating the inverter, including heat and voltage hazards.
Product Description
Overview
Describes Growatt inverters as grid-tied units converting DC to AC for public grid feed-in.
Type Label
Explains how type labels provide unique identification and product characteristics.
Dimensions and Weight
Lists the physical dimensions and weight for various Growatt inverter models.
Transport and Storage
Provides guidelines for safe transportation and storage of the inverter to maintain its condition.
Advantages of Inverter
Highlights key features and benefits, such as high efficiency and easy installation.
Installation
Safety Instructions
Emphasizes safety precautions and adherence to electrical codes during installation.
Selecting Mounting Location
Guides on choosing an appropriate location, considering weight, environment, and ventilation.
Mounting the Inverter
Details the process of physically mounting the inverter, including bracket installation.
Connect Switch
Explains the necessity of DC and AC switches for securely separating the inverter.
Grounding
Addresses grounding requirements for transformerless inverters and PV modules.
Connect Grid Type
Lists suitable grid types (TN-C, TN-S, TT) for connecting the inverter.
Electrical Connection
Provides detailed instructions and safety warnings for all electrical connections.
Safety
Highlights lethal voltage dangers and ESD precautions during electrical work.
Connection to the Grid (AC)
Details procedures for connecting the inverter to the AC grid via a circuit breaker.
Connecting the PV Array (DC & Conditions)
Covers conditions and procedures for connecting the DC input from PV modules.
Inverter Demand Response Modes (DRMs)
Explains the function of demand response modes and RJ45 socket pin assignments for Australia.
Commissioning
Parameters Setting
Guides on configuring display language, luminance, communication address, and grid voltage.
Language Setting
Describes the steps to set the inverter's display language via password input.
LCD Luminance Setting
Explains how to adjust the LCD display's brightness and contrast.
Communication Address Setting
Details the process for setting the communication address for the inverter.
Queensland Grid Voltage Range
Specific setting for Queensland grid voltage range for Ergon Energy area.
Auto Test Function (Italy)
Instructions for enabling and running the auto test function, specific to Italy.
Independent Function Option
Covers options for country-specific settings and independent functions.
Country Selecting
Guides on selecting the appropriate country setting for the inverter's operation.
Auto Test Procedures and Specs
Details the specifications and procedures for performing the inverter's auto test.
GFCI Function
Explains the Ground-Fault Circuit Interrupter function for preventing electric shock.
PV Isolation Detection
Describes the protection mechanism measuring PV panel to earth resistance.
LCD Display
Details the inverter's LCD display, including status and content.
General LCD Display
Shows the starting-up sequence and general information displayed on the LCD.
First Line of LCD
Describes the content and remarks for the first line of the LCD display.
Second Line of LCD
Describes the content and remarks for the second line of the LCD display.
LCD Control
Explains how to control the LCD backlight and display.
Communication
Covers communication methods like RS232 and optional WiFi modules.
RS232 Standard Communication
Details using RS232 for single-point communication with the inverter.
WiFi Optional Communication
Explains the use of optional WiFi modules for monitoring.
Commissioning the Inverter
Final steps to complete the inverter's commissioning process after connection.
Monitoring Tool Instructions
Provides instructions for using monitoring software like ShineNet and ShineVision.
ShineNet Software
Details the ShineNet software for monitoring Growatt inverters via RS232 or Bluetooth.
ShineVision Monitoring Device
Describes ShineVision as a wireless monitoring device for multiple inverters.
ShineWebBox
Introduces ShineWebBox as a cost-effective monitoring device for solar power plants.
Startup and Shutdown the Inverter
Start Up the Inverter
Step-by-step guide for starting the inverter after connecting power sources.
Shutdown the Inverter
Procedures for safely shutting down the inverter and its components.
Operation Modes
Waiting Mode
Describes the inverter's state when powered but not yet connected to the grid.
Normal Mode
Explains the operational status when the inverter is functioning correctly and connected to the grid.
Fault Mode
Details the inverter's status and display indications during system faults.
Shutdown Mode
Describes the state when the inverter automatically stops due to low sunlight or DC switch off.
Maintenance and Cleaning
Checking Heat Dissipation
Guides on improving heat dissipation if the inverter reduces output power due to high temperature.
Checking the DC Switch
Instructions for inspecting the DC switch for damage and performing contact cleaning.
Cleaning the Inverter
Recommends using water and cloth for cleaning inverter parts, avoiding solvents.
Trouble Shooting
Warnings (W)
Lists and explains warning codes indicating the inverter's current status.
Errors (E)
Identifies error codes that signify equipment failure, faults, or incorrect settings.
Decommissioning
Dismantling the Inverter
Provides steps and safety precautions for safely removing the inverter from its installation.
Packing the Inverter
Guidelines for packing the inverter securely for transport or storage.
Storing the Inverter
Recommendations for storing the inverter in a dry environment within a specific temperature range.
Disposing of the Inverter
Advises on proper disposal of faulty inverters according to electronic waste regulations.
Technical Data
Specification
Presents detailed technical specifications for Growatt inverter models.
DC Connector Info
Provides information on the DC connector type (H4) and its features.
Torque
Specifies torque values for various screws and terminals used during installation.
PV System Installation
Single Inverter Installation
Illustrates the PV system connection diagram for a single inverter setup.
Multi Inverter Installation
Shows connection diagram for a PV system with multiple inverters.
Compliance Certificates
Certificate List
Lists the various certifications and standards the Growatt inverters comply with.
Download Address
Provides a URL for downloading related documentation and firmware.

Table of Contents

Save PDF