9
3D Touch Probes
9.2
Touch Probe Cycles in the MANUAL and ELECTRONIC HANDWHEEL Operating Modes
Displaying a basic rotation
The angle of the basic rotation appears after
ROTATION ANGLE whenever PROBING ROT is
selected. It is also shown in the additional status
display (see page 1-26) under ROTATION.
In the status display a symbol is shown for a basic
rotation whenever the TNC is moving the axes
according to a basic rotation.
To cancel a basic rotation:
0
9-10
Select the probe function with the soft key PROBING ROT.
Set the ROTATION ANGLE to 0.
ENT
Terminate the probe function.
END
Fig. 9.11:
Displaying the angle of an active basic rotation
TNC 425/TNC 415 B/TNC 407