Sign In
Upload
Download
Table of Contents
Contents
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
Print this page
×
Bookmark added
×
Added to my manuals
Manuals
Brands
HT Manuals
Measuring Instruments
COMBI420
User manual
HT COMBI420 User Manual
400 series
Hide thumbs
1
Table Of Contents
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
page
of
88
Go
/
88
Contents
Table of Contents
Bookmarks
Table of Contents
Table of Contents
1 Safety Precautions and Procedures
Preliminary Instructions
During Use
After Use
Overvoltage Categories - Definitions
2 General Description
Introduction
Instrument Operation
3 Preparation for Use
Initial Checks
Instrument Power Supply
Calibration
Storage
4 Operation Description
Instrument Description
Backlighting
Keyboard Description
Display Description
Initial Screen
5 Main Menu
Auto ÷ Pwr
SET - Instrument Settings
Language
Auto Power off
Nominal Voltage
Frequency
System
Mem
6 Electrical System Test
Auto
Description of Anomalous Results
LOWOHM: Continuity Test of Earth Leads with 200Ma
CAL Mode
Description of Anomalous Results
M: Measurement of the Insulation Resistance
Description of Anomalous Results
RCD: Test on A-Type and AC-Type Rcds
AUTO Mode
Mode
X½ Mode
X1, X2, X5 Mode
Mode
RA Mode
Description of Anomalous Results
LOOP: Measurement of Line/Loop Impedance
P-N Mode
P-P Mode
P-PE Mode in TT or TN Systems
P-PE Mode in IT Systems
Description of Anomalous Results
R a 15Ma: Measurement of the Total Earth Resistance through the Socket-Outlet
Description of Anomalous Results
123: Phase Sequence Test
Description of Anomalous Results
7 Auxiliary Measurements
AUX: Real Time Measurement of the Environmental Parameters
Db Mode
AIR, RH, TMP °F, TMP °C, Lux Mode
Description of Anomalous Results
LEAK: Real Time Measurement of the Leakage Current through an External Clamp
Description of Anomalous Results
8 Mains Analysis
PWR: Real Time Measurement of the Mains Parameters
PAR Mode
HRM V Ane HRM I Mode
9 Memory
How to Save a Measure
Description of Anomalous Results
Saved Data Management
How to Recall a Measure
How to Delete the Last Measure or All of Them
Description of Anomalous Results
10 Connecting the Instrument to a Pc
11 Maintenance
General
Battery Replacement
Instrument Cleaning
End of Life
12 Specifications
Technical Feratures
Safety Specification
General
Reference Standards for Verification Measurements
Aux
General Characteristics
Environment
Environmental Working Conditions
Accessories
13 Service
Warranty Conditions
14 Practical Reports for Electrical Tests
Continuity Measurement on Protective Conductors
Purpose of the Test
Installation Parts to be Checked
Allowable Values
Insulation Resistance Measurement
Purpose of the Test
Check of the Circuit Separation
Definitions
Purpose of the Test
Installation Parts to be Checked
Allowable Values
Working Test of RCDS
Purpose of the Test
Installation Parts to be Checked
Allowable Values
Note
Test of RCD Tripping Current
Purpose of the Test
Installation Parts to be Checked
Allowable Values
Note
Measurement of Short-Circuit Impedance
Purpose of the Test
Installation Parts to be Checked
Fault Loop Impedance Measurement
Earth Resistance Measurementin TT Systems
Purpose of the Test
Installation Parts to be Checked
Voltage and Current Harmonics
Theory
Limit Values for Harmonics
Presence of Harmonics: Causes
Power and Power Factor Definition
Presence of Harmonics: Consequences
Note
Conventions on Powers and Power Factors
Advertisement
Quick Links
1
Lowohm: Continuity Test of Earth Leads with 200Ma
2
Rcd: Test on A-Type and Ac-Type Rcds
3
Loop: Measurement of Line/Loop Impedance
4
R a 15Ma: Measurement of the Total Earth Resistance through the Socket-Outlet
Download this manual
ISO410 - SPEED418 - COMBI419 - COMBI420
Copyright HT ITALIA 2012
Release EN 1.07 - 05/06/2012
Table of
Contents
Previous
Page
Next
Page
1
2
3
4
5
Advertisement
Table of Contents
Need help?
Do you have a question about the COMBI420 and is the answer not in the manual?
Ask a question
Questions and answers
Related Manuals for HT COMBI420
Measuring Instruments HT COMBI419 User Manual
400 series (88 pages)
Measuring Instruments HT C2006 Installation Manual
Usb – optical rs232 adapter for ht italia instruments (6 pages)
Measuring Instruments HT EASYTEST COMBI519 User Manual
(112 pages)
Measuring Instruments HT 400 Series User Manual
(88 pages)
Measuring Instruments HT COMBI421 User Manual
(88 pages)
Measuring Instruments HT ISO410 User Manual
400 series (88 pages)
Measuring Instruments HT I-V600 User Manual
(81 pages)
Measuring Instruments HT HT7 User Manual
(16 pages)
Measuring Instruments HT I-V400w-SOLAR I-Vw User Manual
(80 pages)
Measuring Instruments HT 64 User Manual
(36 pages)
Measuring Instruments HT PVCHECKs-PRO User Manual
(64 pages)
Measuring Instruments HT VEGA74 User Manual
(60 pages)
Measuring Instruments HT PV CHECKs User Manual
(107 pages)
Measuring Instruments HT PQA400 User Manual
Power quality analyzer (124 pages)
Measuring Instruments HT RCDX10 User Manual
(4 pages)
Measuring Instruments HT VEGA78 User Manual
(103 pages)
Summarization of Contents
SAFETY PRECAUTIONS AND PROCEDURES
Safe Operation Guidelines
Instructions for safe use, including preliminary, during, and after use recommendations.
Overvoltage Categories Definitions
Definitions of measurement categories (IV, III, II, I) relevant to electrical safety.
GENERAL DESCRIPTION AND PREPARATION FOR USE
Instrument Introduction and Operation
Overview of the 400 Series, its capabilities, and basic operation.
Pre-Use Checks and Power Supply
Initial checks, package content, battery, calibration, and storage guidelines.
INSTRUMENT OPERATION AND MAIN MENU
Instrument Layout and Controls
Identification of front, upper, and side panel components, including buttons and connectors.
Keyboard, Display, and Settings
Explanation of keyboard functions, display features, and access to instrument settings.
Main Menu Navigation
Accessing and navigating the main menu for measurement selection and configuration.
ELECTRICAL SYSTEM TEST PROCEDURES
AUTO Mode Test Sequence
Automatic sequence for earth resistance, RCD tripping time, and insulation resistance.
LOWOHM Continuity Test
Performing continuity tests with 200mA, including CAL mode and anomalous results.
ΜΩ Insulation Resistance Measurement
Measuring insulation resistance with various test voltages (50V-1000V).
RCD Test Operations and Modes
Testing RCDs including AUTO mode and specific test parameters like IdN.
LOOP IMPEDANCE, EARTH RESISTANCE, AND PHASE SEQUENCE TESTS
LOOP Impedance Measurement
Measuring line/loop impedance and prospective short circuit current.
Ra 15mA Earth Resistance Test
Measuring total earth resistance without tripping RCDs.
123 Phase Sequence Test
Determining the sequence of phases and handling incorrect results.
AUXILIARY MEASUREMENTS AND MAINS ANALYSIS
AUX Environmental Parameter Measurement
Measuring air speed, humidity, temperature, light, and noise levels.
LEAK Leakage Current Measurement
Measuring leakage current using an external clamp.
PWR Mains Parameter Measurement
Measuring mains voltage, current, power, and power factor.
MEMORY MANAGEMENT AND PC CONNECTION
Saving, Recalling, and Deleting Measures
Procedures for managing stored measurement data and handling anomalies.
Connecting Instrument to PC
Steps for transferring data from the instrument to a computer.
INSTRUMENT MAINTENANCE AND SPECIFICATIONS
General Maintenance and Battery Replacement
Guidelines for instrument care, cleaning, and battery replacement.
Technical Specifications Overview
Detailed technical data, ranges, resolutions, and uncertainties for measurements.
SPECIFICATIONS: STANDARDS, ENVIRONMENT, ACCESSORIES
Reference Standards and Environmental Conditions
Standards for verification, operating limits, and accessory information.
SERVICE AND WARRANTY INFORMATION
Warranty Terms and Service Procedures
Details on product warranty, coverage, and steps for instrument service.
PRACTICAL TESTS: CONDUCTOR CONTINUITY AND INSULATION
Continuity Measurement on Protective Conductors
Procedures for checking conductor continuity, purpose, parts, and allowable values.
Insulation Resistance and Circuit Separation Tests
Insulation test purpose and circuit separation checks, including definitions.
RCD TESTS: ALLOWABLE VALUES AND TRIPPING CURRENT
RCD Working Test Procedures and Values
RCD testing procedures, allowable values, and installation parts to check.
RCD Tripping Current Test
Checking the actual tripping current of RCDs, purpose, and allowable values.
SHORT-CIRCUIT IMPEDANCE, FAULT LOOP, AND EARTH RESISTANCE TESTS
Short-Circuit Impedance Measurement
Purpose, installation parts, and allowable values for impedance testing.
Fault Loop Impedance and Earth Resistance
Understanding fault loop composition and earth resistance measurements.
HARMONICS ANALYSIS AND POWER FACTOR
Voltage and Current Harmonics
Explanation of harmonic distortion, limits, causes, and consequences.
Power and Power Factor Definitions
Definitions of power types, power factor, and related conventions.
Table of Contents
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL
Need help?
Do you have a question about the COMBI420 and is the answer not in the manual?
Questions and answers