E
[ F3 ( ATT )] Key ( Attenuator )
By pressing this key, the display attenuation can be
switched as shown below. The noise level on the band
will vary according to conditions, your antenna, the
time of day, etc.; please select the appropriate value
for current conditions.
0 dB 10 dB
20 dB
[ F6 ( CTR/FIX )] Key
By pressing this key, it is possible to switch between
the CTR mode and FIX mode.
In the CTR mode, the current operating frequency is
displayed at the center of the screen; in the FIX mode,
the frequency selected via the Menu is fixed at the
left edge of the display.
Advice: In either CTR or the FIX mode, the current
operating frequency is indicated on the screen by the
yellow arrow ( ) , for ease of status recognition.
Press the [ MENU ] button momentarily to enter the
Menu mode. Select the item which you want to change
by rotating the Main Tuning Dial knob (in this case,
the item will be one of the items in the range from
SCOPE "105 SCP 1.8 FI" to "115 SCP 50.0 FI").
Then change the setting by rotating the [ SUB VFO-
B ] knob.
When the change is completed, press and hold in the
[ MENU ] button for 2 seconds to save the change.
DMU-2000 D
M
F
K
0 dB ......
( L
FIX M
S
U
S
S
[ F7 ( LBWS )] Key
Press this key to activate the "Limited Band Width
Sweep" (LBWS) function, which permits high-speed
sweeping of a band segment.
As the bandwidth is set narrower, the sweep speed
becomes faster, allowing the scope to capture signals
with quicker resolution. The bandwidth can be set to
50 %, 30 %, or 10 % of the full span. The sweep speed
becomes faster by the following amounts:
50 %: about 2 times faster
30 %: about 3 times faster
10 %: about 10 times faster
NORMAL LBWS-1 ( 50% )
LBWS-2 ( 30% ) LBWS-3 ( 10% ) NORMAL ......
Advice: When you enter the LBWS mode, the func-
tion keys below the Display change.
It is possible to move the sweep position by pressing
the [ F5 ( )] and [ F6 ( )] key.
If you want to return to normal operation, press the
[ F7 ( LBWS )] key as needed.
Please note that LBWS can not be used in the FIX
mode. Please use LBWS only in the CTR mode.
[ DISPLAY ] Key
Press this key momentarily to switch the Function
key's function between the "Page Select Key" and the
"Function Key."
Press and hold in this key to disable the Function keys
(except this key).
)
E
F
If you do not want to save the change, press the
[ MENU ] button momentarily. The radio will go back
to the previous condition/situation.
There are many setup items in the Menu mode, and
they are grouped for easy recognition; the group name
is displayed at the top left corner of the list screen. It
is usually more convenient if you initially select the
group by rotating the Main Tuning Dial knob, and then
select the item you want.
S
S
S