Single Slot Usb Cradle - Motorola WT4000 - Wearable Terminal - Win CE 5.0 Professional 520 MHz User Manual

Wearable terminal
Table of Contents

Advertisement

Single Slot USB Cradle

Troubleshooting the Single Slot USB Cradle
Table 4-4
Symptom
Charge Status
Cradle is not receiving
LEDs do not light
power.
when wearable
Wearable terminal is
terminal or spare
not seated firmly in the
battery is
cradle.
inserted.
Spare battery is not
seated firmly in the
cradle.
Wearable
Wearable terminal was
terminal battery
removed from cradle or
is not charging.
cradle was unplugged
from AC power too
soon.
Battery is faulty.
The wearable terminal
is not fully seated in
the cradle.
Ambient temperature
of the cradle is too
warm or too cold.
Spare battery is
Battery inserted
not charging.
incorrectly.
Battery is faulty.
Ambient temperature
of the cradle is too
warm or too cold.
Possible Cause
Ensure the power cable is connected securely to both the cradle
and to AC power.
Remove and re-insert the wearable terminal into the cradle,
ensuring it is firmly seated.
Remove and re-insert the spare battery into the charging slot,
ensuring it is firmly seated.
Ensure cradle is receiving power. Ensure wearable terminal is
seated correctly. Confirm main battery is charging. If a wearable
terminal battery is fully depleted, it can take up to four hours to
fully recharge a standard capacity battery and up to eight hours for
an extended capacity battery (if the wearable terminal is off, and
longer if the wearable terminal is operating).
View battery status by selecting
Power
Verify that other batteries charge properly. If so, replace the faulty
battery.
Remove and re-insert the wearable terminal into the cradle,
ensuring it is firmly seated.
Move the cradle to an area where the ambient temperature is
between 0°C and 40°C (32°F and 104°F).
Verify that the battery is oriented properly and firmly seated in the
battery well correctly with the contacts facing down. See
3-3 on page 3-6
Verify that other batteries charge properly. If so, replace the faulty
battery.
Move the cradle to an area where the ambient temperature is
between 0 °C and 40 °C (32 °F and 104 °F).
Maintenance & Troubleshooting 4 - 11
Solution
Start
icon.
for proper battery orientation.
>
>
>
Settings
Control Panel
Figure

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wt4070Wt4090

Table of Contents