Summary of Contents for SCHUNK VERO-S SPM plus 138
Page 1
Fixture membrane VERO-S SPM plus 138 Assembly and Operating Manual...
Page 2
Imprint Imprint Copyright: This manual is protected by copyright. The author is SCHUNK SE & Co. KG. All rights reserved. Technical changes: We reserve the right to make alterations for the purpose of technical improvement. Document number: 1370574 Version: 03.00 | 02/04/2025 | en...
5.4 Clamping the workpiece ............... 18 6 Maintenance and care ................20 7 Problem analysis .................. 21 8 Storage....................22 9 Part list ..................... 23 10 Assembly drawing ................24 03.00 | VERO-S SPM plus 138 | Fixture membrane | en | 1370574...
Catalog data sheet for the attached product * Technical data sheet for optional attachments * Approval drawings The documents labeled with an asterisk (*) can be downloaded from schunk.com. 03.00 | VERO-S SPM plus 138 | Fixture membrane | en | 1370574...
2.2 Inappropriate use Inappropriate use of the fixture membrane and the quick change pallet system includes using the product as lifting equipment, a toolholder, a press or a gripper. 03.00 | VERO-S SPM plus 138 | Fixture membrane | en | 1370574...
Use of personal protective equipment Personal protective equipment serves to protect staff in the event of a danger that may interfere with their health or safety at work. 03.00 | VERO-S SPM plus 138 | Fixture membrane | en | 1370574...
Ø 125 mm Min. clamping depth 3 mm Max. clamping depth 20 mm Repeat accuracy < 0.01 mm Weight 1.5 kg * Applies to mounted quick-change pallet system 03.00 | VERO-S SPM plus 138 | Fixture membrane | en | 1370574...
The clamping device is suitable for light machining of the most varied materials and workpiece contours. 03.00 | VERO-S SPM plus 138 | Fixture membrane | en | 1370574...
The positioning of the fixture membrane is done using the upper centering diameter of the NSE plus and NSE3 quick change pallet modules: Ø 138 0 / -0.01 03.00 | VERO-S SPM plus 138 | Fixture membrane | en | 1370574...
Page 14
The indexing pin must engage in one of the two alignment grooves. The clamping system is already then fixed for direct workpiece clamping with high repeat accuracy and ready for operation. 03.00 | VERO-S SPM plus 138 | Fixture membrane | en | 1370574...
Page 15
The technical data and descriptions for operating the mounted quick-change pallet systems can be found in the respective assembly and operating instructions. Mounting and connecting the NSE plus & NSE3 03.00 | VERO-S SPM plus 138 | Fixture membrane | en | 1370574...
3 mm is sufficient for a workpiece height of maximum 40 mm. The clamping contour should be milled in as close as possible to the center of the fixture membrane. 03.00 | VERO-S SPM plus 138 | Fixture membrane | en | 1370574...
Page 17
Quick change pallet system unlocked * Clamping station * Quick change pallet system not included in the scope of delivery of SPM plus Preparation for production of the clamping contour 03.00 | VERO-S SPM plus 138 | Fixture membrane | en | 1370574...
Decouple the compressed air supply at the port for "Turbo function". The workpiece is securely clamped and can be machined (see figure "Insertion and machining of the workpiece", right). 03.00 | VERO-S SPM plus 138 | Fixture membrane | en | 1370574...
Page 19
Quick-change pallet system * clamped unlocked state * Quick-change pallet system not included in the scope of derlivery of SPM plus Insertion and machining of the workpiece 03.00 | VERO-S SPM plus 138 | Fixture membrane | en | 1370574...
The system may only be started up again once the faults have been corrected (for example, by replacement of a damaged fixture membrane). Use original SCHUNK spare parts only when exchanging damaged parts. 03.00 | VERO-S SPM plus 138 | Fixture membrane | en | 1370574...
A clamping segment of the collet is damaged. The tolerance variation of the workpieces was exceeded. The shape accuracy of the clamping contour and the workpiece contour have not been made to go together. 03.00 | VERO-S SPM plus 138 | Fixture membrane | en | 1370574...
Only store the product in dry rooms. Protect the product from major temperature fluctuations. NOTE: Before recommissioning, clean the product and all attachments, check for damage, functionality and leaks. 03.00 | VERO-S SPM plus 138 | Fixture membrane | en | 1370574...
Collet IXB V1 indexing pin Adjusting ring O-ring * O-rings are wearing parts and are recommended to be replaced during maintenance. X Included in the accessory kit. 03.00 | VERO-S SPM plus 138 | Fixture membrane | en | 1370574...
Assembly drawing 10 Assembly drawing 03.00 | VERO-S SPM plus 138 | Fixture membrane | en | 1370574...
Page 25
03.00 | VERO-S SPM plus 138 | Fixture membrane | en | 1370574...
Page 26
03.00 | VERO-S SPM plus 138 | Fixture membrane | en | 1370574...
Page 27
03.00 | VERO-S SPM plus 138 | Fixture membrane | en | 1370574...
Page 28
H.-D. SCHUNK GmbH & Co. Spanntechnik KG Lothringer Str. 23 D-88512 Mengen Tel. +49-7572-7614-0 info@de.schunk.com schunk.com Folgen Sie uns I Follow us Wir drucken nachhaltig I We print sustainable...
Need help?
Do you have a question about the VERO-S SPM plus 138 and is the answer not in the manual?
Questions and answers