Thank you for purchasing this Furrion® Chill Rooftop Air Conditioner. Before operating your new product, please read these instructions carefully. This will ensure safe use and reduce the risk of injury. This instruction manual contains information for installation, operation, maintenance of the product and safe use.
Electric shock − Fire hazards − Injury − ● All Furrion product referenced in this manual is to be installed in accordance with local and national codes, including the latest editions of the following standards: USA: NFPA 1192 −...
Handling Electrical CAUTION Cables ● The rooftop air conditioner must be installed securely so that it cannot WARNING fall down. ● Only operate the rooftop air The electrical power supply must only conditioner if you are certain that be connected by a qualified electrician. the housing and the cables are not damaged.
Before Installing ● Filter x 2 Read this installation manual completely ● Decoration Plate x 1 before installing the rooftop air ● Self-tapping Screws x 6 conditioner. ● PE foam x 1 The following tips and instructions must ● Instruction Manual x 1 be observed while installing the rooftop air conditioner.
Page 6
It is preferred that the air conditioner be ● Check the inside of the RV for installed on a relatively flat and horizontal return air kit obstructions. (i.e. door roof section measured when the RV is openings, room dividers, curtains, parked on a level surface.
3” (75mm) to 6” Section 2.7.2. (152mm). For other thickness, please 1. Mark a 141/4” x 141/4” (+1/2”) square on contact Furrion or Furrion authorized the roof and carefully cut an opening. service agent. Installing in an Existing Opening 1.
2. Using the roof opening as a guide, cut Roof Cavity 3”-6” (75mm-152mm) a matching hole in the ceiling. Depth NOTE: Maintain structural integrity. Duct Cross 21 Sq. In. Min. Sectional Area Otherwise damage to product and/or RV could occur. Always observe the 11/2”...
SIDE VIEW these alternate configurations and (TOWARD BACK OF RV) methods MUST be approved by Furrion in writing. Roof ● Duct size ● Duct layout Roof Opening ●...
Laying the Connecting 1. Refer to the applicable electric code guidelines for sizing the appropriate Cables wire gauge, length and type. 2. Route a 115VAC supply wire with The rooftop air conditioner must be ground wire from the time delay fuse connected to an electric circuit which is or circuit breaker box to the roof able to supply the required power supply...
Installation Installing the Rooftop Unit Installing the Wall Thermostat (model: CAUTION FACW12SA-BL/ ● The rooftop unit weighs FACW12PA-BL/ approximately 100 pounds (45 FACW12ZA-BL, kg). To prevent back injury, use a sold separately) mechanical hoist when lifting or moving the unit. Failure to obey this warning could result in injury.
3. Install the assembled mounting frame Installing the Air and the lower duct divider into the Distribution Box (for rooftop opening. Make sure the “THIS FACT12LA-PS/FACT12LA- WAY FRONT” mark is facing front (the direction of the vehicle) while BL/FACT12SA-PS/ installing. (Fig. 4) FACT12SA-BL models only, same for both ducted and non-ducted...
Page 13
5. Pull to remove the film off the double 8. Use self adhesive foil tape to seal sided sticky tape on the inner side of all remaining gaps around the duct the lower duct divider. (Fig. 6) divider, PE foam and roof opening, completely sealing duct edges as required.
Page 14
10. Loosen the strain relief on top of the 13. Lock the freeze sensor onto the pipe control box and let the 115VAC power of the evaporator. Connect the freeze cord pass through. (Fig. 10) sensor cable of the control box to the NOTE: Always follow the color code freeze sensor of the rooftop.
Page 15
15. Set up the control box dip switches as 16. Connect the wall thermostat cable indicated in the illustration and table and 12VDC power cable to the control below (Fig. 14): box.(Fig. 15) Wall Ther- 12V DC Power Cable mostat Cable LED Cable Fig.
Page 16
19. Install the Air Distribution Box (ADB) 22. Your new rooftop air conditioner has shroud over the mounting frame and now been fully installed in the RV roof. fix with 4 self-tapping screws. (Fig. 21) NOTE: Make sure the “THIS WAY FRONT”...
1. Remove the decoration plate from the air conditioning system by pushing Replacement return air filters can be the side tabs to release. (Fig. 22) ordered directly from Furrion. Fig. 22...
Freeze sensor has tripped. Outer temperature is too low or all air nozzles are closed. Abnormal shutdown Contact an authorized service agent or Furrion Refrigerant leakage (see the detail contact info at the back page of this manual). The rooftop air conditioner is Set the rooftop air conditioner to cooling.
Wiring Diagram DANGER Electrical Shock Hazard ● Disconnect power before servicing. Failure to obey this warning could result in death or serious injury. ● Provide grounding in compliance with all applicable electrical codes. Failure to obey this warning could result in death or serious injury. COMPRESSOR GRN/YEL INDOOR...
Multi Zone Wiring Diagram Air Conditioner 115VAC Input Rear Unit Four Conductor Communication Cable 12VDC Input 2 Furnace 2 Wires Wires Breaker Box Air Conditioner Four Conductor Communication Cable Furrion Thermostat 12VDC Input 2 Wires 115VAC Input Front Unit...
Page 23
Single Zone Premium Wall Thermostat Instruction Manual Model: FACW12PA-BL...
Page 24
Welcome Thank you for purchasing this Furrion ® Single Zone Premium Wall Thermostat. Before operating your new product, please read these instructions carefully. This instruction manual contains information for safe use, installation and maintenance of the product. Please keep this instruction manual in a safe place for future reference. This will ensure safe use and reduce the risk of injury.
Page 25
Contents Welcome .................... 1 Contents .................... 2 About your Thermostat ..............3 Product Features .....................3 Control Buttons .......................3 LCD Icons ........................4 Installation ..................5 What’s in the Box ....................5 Thermostat Installation ..................5 Operation ................... 7 Turn On/Off the Thermostat ..................7 Temperature Format ....................7 Operation Mode .......................7 Set the Temperature ....................9...
About your Thermostat Product Features Your Single Zone LCD thermostat is equipped with a liquid crystal display (LCD) to indicate the temperature set-point in Fahrenheit(°F)/Centigrade(°C) and fan speed. It is also equipped with LCD to indicate the system available operation modes. NOTE: The available operation modes will be different depending on the system installed in your RV.
Installation What’s in the Box Make sure you have all the following items included in the packaging. If any item is damaged or missing, contact your dealer. – Thermostat x 1 – Instruction Manual x 1 Fig. 2 Thermostat Cables –...
Page 29
Installation 5. Connect the cables to thermostat. Rotate the thermostat clockwise until it clips into place. (Fig. 4 and Fig. 5) Thermostat cables Fig. 4 Fig. 5...
Operation Temperature Format Your Furrion wall thermostat has been preprogrammed with factory default settings. Review the settings below and adjust to your comfort level. FACTORY DEFAULT SETTINGS HEATING 68ºF / 20ºC COOLING 72ºF / 22ºC FAN SPEED AUTO MODE AUTO FURNACE DIFFERENTIAL 2ºF...
Page 31
Operation are 5 available modes (AUTO, COOL, COOL MODE HEAT, FAN and DRY) for you to select. ● The system will cycle the See the following tables for detailed compressor on and off based on information of each mode. the room temperature and the NOTE: The HEAT mode is only available temperature set-point.
Operation HEAT MODE FAN MODE ● The temperature set-point is not NOTE: The HEAT mode is only available when the furnace is enabled. available. ● The system will cycle the furnace ● There are 3 fan speed selections in on and off based on the room this mode.
Operation predefined colors of LED light in the air 60ºF~86ºF (16ºC~30ºC). distribution box. 1. Press button to toggle to your 1. Press LIGHT button on the desired mode. thermostat to turn on the mood light. 2. Press button to increase or 2.
Special Features Auto Fan LCD Error Code When the auto fan mode is selected, The following error code will be the fan speed will vary depending on displayed on the LCD when the system the temperature difference between the detects one of the following faults has temperature set-point and the room occurred.
Specifications DC Input Power DC 12V Power Consumption <0.5W Baud Rate 9600bps Dimension 3 x 3 x 15/16” (75 x 75 x 22.5mm) Weight 0.06kg LCD Viewing angle 12 o’clock...
Warranty FURRION WARRANTS FOR A PERIOD OF 1 YEAR FROM DATE OF RETAIL PURCHASE BY THE ORIGINAL END-USE PURCHASER, THAT THIS PRODUCT, WHEN DELIVERED TO YOU IN NEW CONDITION, IN ORIGINAL PACKAGING, FROM A FURRION AUTHORIZED RESELLER AND USED IN NORMAL CONDITIONS, IS FREE FROM ANY DEFECTS IN MANUFACTURING, MATERIALS, AND WORKMANSHIP.
Page 38
TO LOST PROFITS, DOWNTIME, GOODWILL, DAMAGE TO OR REPLACEMENT OF ANY EQUIPMENT OR PROPERTY, ANY COSTS OF RECOVERING, REPROGRAMMING, OR REPRODUCING ANY PROGRAM OR DATA STORED IN OR USED WITH FURRION PRODUCTS. FURRION’S TOTAL LIABILITY IS LIMITED TO THE REPAIR OR REPLACEMENT OF THIS PRODUCT PURSUANT TO THE TERMS OF THIS WARRANTY.