Cube 18k ducted rv rooftop air conditioner (22 pages)
Summary of Contents for Furrion CHILL FACR08HESA2-BL
Page 1
8K ROOFTOP AIR CONDITIONER WITH ELECTRONIC CONTROL MODEL (LIPPERT PN) FACR08HESA2-BL (2024006030) FACR08HESA2-PS (2024006031) INSTRUCTION MANUAL ADB: FACT12SA2-PS Control Box: FACC10ESSA2-BL (Sold Separately) * Pictures shown here are for reference only.
● This appliance is intended to be used fall down. in the recreational vehicle ● Only operate the rooftop air ● All Furrion product referenced in conditioner if you are certain that this manual is to be installed in the housing and the cables are not accordance with local and national damaged.
Contact due to flammable refrigerant and Furrion for further details before gas. All air conditioner products purchase or use. contain refrigerants, which under the guidelines of federal law must be removed before disposal.
Before Installing Rooftop Unit Upper Duct Lower Duct Bolt Divider Divider Air Distributor Box (sold separately): Read this installation manual completely PE Foam before installing the rooftop air conditioner. Mounting Frame The following tips and instructions must Control Box be observed while installing the rooftop air conditioner.
Page 6
New Opening When no roof vent is available or another 13 ⁄ ” 11 5/8” (345mm) (296mm) location is desired, the following is recommended: ● For one unit installation - the air 34 ⁄ ” 27 ⁄ ” 25 5/8” 30 1/4”...
3” (75mm) to 6” Section 2.7.2. (152mm). For other thickness, please 1. Mark a 141/4” x 141/4” (+1/2”) square on contact Furrion or Furrion authorized the roof and carefully cut an opening. service agent. Installing in an Existing Opening 1.
2. Using the roof opening as a guide, cut Roof Cavity 3”-6” (75mm-152mm) a matching hole in the ceiling. Depth NOTE: Maintain structural integrity. Duct Cross 21 Sq. In. Min. Sectional Area Otherwise damage to product and/or RV could occur. Always observe the 11/2”...
Failure to obey this warning could methods MUST be approved by Furrion result in death or serious injury. in writing. ● Duct size ● Duct layout...
Page 10
NOTE: 18AWG max should be used, NOTE: With multiple air conditioners Furrion recommends using a standard on a 50 amp service, it is best to thermostat wire with at least 4-wires. balance between the line voltage legs. 2. Terminate with at least 15” (381mm) of NOTE: Refer to rooftop unit wire end for easy connection.
Installation Installing the Rooftop Unit Installing the Wall Thermostat CAUTION There are 2 types of wall thermostat ● The rooftop unit weighs (sold separately) for you to select. approximately 100 pounds (45 ● FACW10ESSA2-BL: Single zone basic kg). To prevent back injury, use a wall thermostat mechanical hoist when lifting or ●...
Page 12
2. Reach up into the return air opening and pull down the rooftop unit electric cord. Ensure all terminated wire ends specified in “Preparing Wire Connections” section are accessible. (Fig. 3) Roof Opening Fig. 5 Fig. 5 NOTE: Tighten bolts until the white indicators are touching the top of the Ceiling Thickness Thermostat Wire...
6. Use self adhesive foil tape to seal all remaining gaps around the duct divider, PE foam and roof opening, completely sealing duct edges as required. (Fig 8) NOTE: Clean metal surface with a degreaser to ensure good adhesion of the foil tape.
NOTE: The analog cable is not used (selected DIP 3 Reserved and positioned out of the way when models) the air conditioner unit is connected Furnace with a Furrion wall controller/ thermostat. Furnace DIP 4 Furnace Heat Electric Strip Off...
Page 15
3. Loosen the strain relief and crossing, otherwise the control box compartment cover of the control could be malfunction or even on fire. box and pass the 115VAC power cord through the strain relief hole and re- tighten the cable clamp until properly restrained.
2. Stick the freeze sensor onto the center bottom of the evaporator about 13/16’’ (30mm) depth. Then fix it with the clamp. (Fig. 22) 12VDC wire from the ceiling 3. Extend the Room Temperature sensor into the middle of the return 12VDC Power Cable Ground cable Fig.
Page 17
Fig. 24 Fig. 24 Fig. 26 Fig. 26 6. Align the filter tabs with mating notches and push to snap the filters 8. Install the decoration plate back. Your into the ADB shroud. (Fig. 25) new rooftop air conditioner has now been fully installed in the RV roof.
Cleaning and Maintenance Repairs and Maintenance Under no circumstances shall potential sources of ignition be used in the Only a qualified personnel or a certified searching for or detection of service technician is permitted to carry refrigerant leaks. A halide torch (or any out any repairs of the air conditioner.
Freeze sensor has tripped. Outer temperature is too low or all air nozzles are closed. Abnormal shutdown Contact an authorized service agent or Furrion Refrigerant leakage (see the detail contact info at the back page of this manual). The rooftop air conditioner is Set the rooftop air conditioner to cooling.
Water enters the vehicle Contact an authorized service agent or Furrion The seals are damaged. (see the detail contact info at the back page of this manual). No supply voltage connected. Check the power supply.
Wiring Diagram DANGER Electrical Shock Hazard ● Disconnect power before servicing. Failure to obey this warning could result in death or serious injury. ● Provide grounding in compliance with all applicable electrical codes. Failure to obey this warning could result in death or serious injury. CCD-0008666 Rev: 08.02.24...
Multi Zone Wiring Diagram Air Conditioner 115VAC Input Rear Unit Four Conductor Communication Cable 12VDC Input 2 Furnace 2 Wires Wires Breaker Box Air Conditioner Four Conductor Communication Cable Furrion Thermostat 12VDC Input 2 Wires 115VAC Input Front Unit CCD-0008666 Rev: 08.02.24...
Page 23
Furrion, LLC (Furrion) are wholly owned subsidiaries of Lippert Components, Inc. (Lippert) Furrion, LLC (Furrion) sont des filiales en propriété exclusive de Lippert Components, Inc. (Lippert) Furrion, LLC: 52567 Independence Ct., Elkhart, IN, 46514 Furrion Innovation Center & Institute of Technology Centre d’innovation et institut de technologie Furrion...
Need help?
Do you have a question about the CHILL FACR08HESA2-BL and is the answer not in the manual?