Furrion FACR09SM-PS User Manual

Furrion FACR09SM-PS User Manual

9k & 12k btu rooftop air conditioner
Hide thumbs Also See for FACR09SM-PS:

Advertisement

Quick Links

Material: 80 GSM Bond Paper or 50# Bond Paper White
Ink: Black
Resolution: 150 DPI or above
Printing method: Offset Printing
Binding: Saddle Stitch
Folded size: 210 x 285 mm (W x H)
This drawing contains proprietary information and trade secrets of The Furrion Company, Inc.
METRIC
[INCH]
METRIC [INCH]
CRITICAL DIMENSION
CHECKING IS COMPULSORY
3
VOLUME
cm
MASS
grams
3
DENSITY
g/cm
GENERAL TOLERANCES
EXCEPT AS NOTED
0 TO 6mm = ±0.1
>6 TO 30mm = ±0.2
>30 TO 80mm = ±0.3
>80 TO 180mm = ±0.4
>180mm = ±0.5
ANGULAR = ± 3°
DO NOT PRINT THIS PAGE
Printing Notes:
Unauthorized use or copying is prohibited.
V1.0
18-Oct-22
REV.
DATE
MATERIAL:
FINISH SPEC:
SCALE:
DATE:
18-Oct-22
NAME:
IM for Low Cost Trim Kit Rooftop Air Conditioner - Electronic
NEW
MODIFICATIONS
COMPOSITE-NO
DRAWN BY:
APPROVED BY:
Grace Sun
Program: Indesign CC
Black
Grace Sun
NAME
Furrion Property Holding Ltd
SHEET 1 OF 1
Mandy Tse
PART NO.
IM-FHA00124
XX
ECN NO.
REVISION
1.0

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FACR09SM-PS and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Furrion FACR09SM-PS

  • Page 1 Resolution: 150 DPI or above Printing method: Offset Printing Binding: Saddle Stitch Folded size: 210 x 285 mm (W x H) This drawing contains proprietary information and trade secrets of The Furrion Company, Inc. Unauthorized use or copying is prohibited. METRIC [INCH]...
  • Page 2 9K & 12K BTU ROOFTOP AIR CONDITIONER FACR09SM-PS[2021132274]; FACR12SM-PS[2022107892]; FACTRCSM-PS[2021132281]; USER MANUAL Product picture for reference only...
  • Page 3: Table Of Contents

    CONTENTS OVERVIEW ..........................................2 Safety Instructions ........................................... 2 Important Installation Requirements ....................................2 Introduction ..............................................2 User Guide ..............................................2 Technical data ............................................3 INSTALLATION ........................................3 Precautions ..............................................3 Installation Position ..........................................3 Preparation for Installation ........................................4 System Wiring ............................................6 CONTROL INSTRUCTIONS .....................................
  • Page 4: Overview

    OVERVIEW Safety Instructions User Guide This manual contains important information to guarantee WARNING correct use of the air conditioner. Include this manual when you pass on the air conditioner to another person. ● This appliance is not intended for use by persons DANGER (including children) with reduced physical, sensory or mental capabilities, or lack of experience and...
  • Page 5: Technical Data

    Technical data NOTE: ● Installation and repair of the air conditioner must only FACR09SM-PS FACR12SM-PS be carried out by qualified personnel who are familiar with the risks involved and the relevant regulations. Rated cooling capacity 2637W 3516W Inadequate repairs may cause serious hazards. Ensure...
  • Page 6: Preparation For Installation

    design of 100kg can meet this requirement. 1 0 5 6 m m ● Check whether there are obstacles (i.e., door openings, partition frames, curtains, ceiling fixtures, etc.) that hinder 187 m m the installation of inner panel of the air conditioner. ●...
  • Page 7 ● In case any deviation is found at the position of NOTE outdoor unit on the roof during the installation of the frame,replace the rooftop unit (the sponge on the rooftop The installation personnel of air conditioning equipment unit must be aligned with the 141/8" x 141/8" (362x362mm) shall be responsible for ensuring structural integrity of the square hole).
  • Page 8: System Wiring

    The through hole of air duct sponge Corresponding terminal Cable gland on control box, on control box should correspond to the hole on from which the main power fixing plate line will be introduced. Air outlet Connecting wire of outdoor ambient temperature sensor and outdoor coil Maintenance port...
  • Page 9 5. Insert the anti-freezing temperature sensor into plastic bracket located on the evaporator, as shown in the Connecting wire following figure: of display lamp board Via hole on the panel Connecting wire of display lamp board Holder for freeze sensor (blue) Screw (4) 3.
  • Page 10: Control Instructions

    CONTROL INSTRUCTIONS Remote Control BUTTON FUNCTION Press the “MODE” button to switch between various modes Set the air conditioner operating (Auto, Cooling, Dry, Fan, and Heating), the system will confirm mode. the selected working mode after 2 seconds, and internal Increase the fan speed.
  • Page 11 Cooling mode Fan mode Press the button to turn on the air Press the button to turn on the air conditioner. conditioner. Press the MODE button to select Press the MODE button to select fan cooling mode. mode. Press UP or DOWN button to set Press the...
  • Page 12: Install/Replace The Remote Control Batteries

    Install/Replace the Remote Control Auto mode Batteries Press the button to turn on the air conditioner. Remove the battery compartment cover. Press the MODE button to select auto 2. Install two AAA batteries (supplied). Ensure batteries are mode. inserted with the proper polarity. 3.
  • Page 13: Maintenance Of Air Conditioner

    If the air conditioner still cannot work normally after confirm whether the generator power matches the air the above inspection, please contact Furrion or Furrion conditioner, whether the generator runs normally and authorized service agent.
  • Page 14: Circuit Diagram Of Outdoor Unit And Panel

    CIRCUIT DIAGRAM OF OUTDOOR UNIT AND PANEL GRN/YEL C OMPRESSOR GRN/YEL O UTDOOR I NDOOR GRN/YEL M O T O R M O T O R CAP CAP CONN 6 PIN CONN HIGH SENSOR C APACITOR GRN/YEL 3 PIN CONN SENSOR BLU/BLK 4WAY VALVE...
  • Page 15 - 13 - Rev: 10-18-22...
  • Page 16 - 14 - Rev: 10-18-22...
  • Page 17 ● 4/F, Flat C & D, The Grid, 133 Wai Yip Street, Kwun Tong, Kowloon, Hong Kong ● Toll free:+1-432-547-7378 ● Email: support@furrion.com ©2007-2023 Furrion Ltd. Furrion® and the Furrion logo are trademarks licensed for use by Furrion Ltd. and registered in the U.S. and other countries.

This manual is also suitable for:

Facr12sm-psFactrcsm-ps202113227420221078922021132281

Table of Contents