Congratulations! You have made an excellent choice. WIGGENS thanks you for the trust you have placed in us. This operating manual has been designed to help you gain an understanding of the operation and possible applications of our instruments. For optimal utilization of all functions, we recommend that you thoroughly study this manual prior to beginning operation.
WIGGENS WS-350R/350W Important: keep operating manual for future use Content 1. Safety .......................... 5 1.1 How to use the Manual ..................5 1.2 Symbols used in this manual ................5 1.3 Exemption for responsibility ................5 1.4 Warning statement ..................... 6 1.5 Caution statement ....................
Page 4
Operating Manual 5.1 Inspection cycle ....................14 5.2 Cleaning of Tray & body unit ................14 5.3 In case of not using for a long time ..............14 6. Trouble shooting ......................15 6.1 Power ....................... 15 6.2 Error on the run ....................15 7.
WIGGENS WS-350R/350W 1. Safety 1.1 How to use the Manual This operation manual describes the important subjects to maintain the product’s functions and to use it safely. Especially, be sure to read <Safety Precaution> carefully before you use this equipment.
Operating Manual 1.4 Warning statement Indicates a hazardous situation which, if not avoided, could result in death or serious injury. Please check and connect properly -the voltage, phase and capacity of power supply on the ID plate before installation. Power supply must be properly grounded. Abnormal grounded connection causes serious damage.
WIGGENS WS-350R/350W 1.5 Caution statement Indicates a hazardous situation which, if not avoided, may result in minor or moderate injury. Do not put heavy things on the power line. Do not put the machine on the line. It may take off the wire coating and causes the electric shock or fire.
Operating Manual 2. Functional Description 2.1 Introductions Rocking/waving shaker is commonly used for mixtures, homogenizing and various hybridization, immunocytochemistry reaction or gel staining / destaining process and over biotechnology. 2.2 Feature 1. The WS350R/WS350W is aimed to be user safe in laboratories, convenient and follow features. 2.
WIGGENS WS-350R/350W (6) Socket: Connect the power cable on the socket. (7) Power switch: It is the main ON/OFF switch and supplying power of the product. 3. Installations and Caution 3.1 Unpacking the package and Inspecting damage during transportations (1) Check to see that the unit is not damaged before unpacking.
Operating Manual 3.3.2 Location conditions Place the unit table as far as possible when in use, and keep suitable distance not to be placed from other instruments. Do not place the unit nearby the other laboratory equipment which can be readily influenced, even by weak motor vibration 3.3.3 Fixing feet and keeping its balance STEP 1: please gently press the feet on the table STEP 2: please check horizontality of the shaker...
WIGGENS WS-350R/350W Use the power cord only supplied with the unit. 4. Operation 4.1 Name and function (1) TFT Display: Check out status of unit through TFT display. Current RPM Setting RPM Off-T It shows remaining time during Timer mode operation It indicates the unit works when the logo show up (2) RPM Set Knob : It can be used to set the desire RPM.
Operating Manual (3) Run time can be verified during shaking if you press TIME button. Activate the time mode you need to click the START/STOP button again. Rotating the knob select Press the START/STOP Push down the knob the the working hour button save the Click the time button cursor will skip to the...
WIGGENS WS-350R/350W STEP 1: press the dial knob the cursor will skip to the hour position. STEP 2: Input hour by rotating the dial knob to right or left direction. STEP 3: Press the dial knob again, the cursor will skip to the minute position.
Operating Manual set the desired angle. 5. Maintenance 5.1 Inspection cycle Inspection cycle Classification Daily Weekly General Power cord Inspect power cord connection at unit ● and receptacle. ● Inspect power cord for wear, cracks or cuts. ● Cleanness for the surface of the unit. Body unit ●...
WIGGENS WS-350R/350W (3) Store in a dry place after packing 6. Trouble shooting 6.1 Power Symptom Causes Actions Compare power source and voltage on the ID Incorrect electric power plate and make sure they are the same.ID plate is found on the back of unit.
Heavy leaning to one side of in rotational the sample tray is Reduce the load or tray in the center. speed located 7. Technical Specifications MODEL Rocking shaker WS-350R Waving shaker WS-350W Shaking system Motion type Rocking type Waving type Speed range(rpm) 5 ~ 100...
▪ Serial number on Identification plate. ▪ Defect and trouble ▪ Application and using condition. 9.2 Disclaimer Wiggens does not cover in case of as below even it is under warranty period. ▪ Abuse, ▪ Abuse, ▪ Misuse, neglect, and accident ▪...
⚫ Copy and complete the Conformation of condition of unit from these operating instructions. ⚫ Please repack the device appropriately for transport and send to WIGGENS Instruments together with the Confirmation of condition of unit. Our contact details WIGGENS GmbH Add:Gässlesweg 22-24, 75334 Straubenhardt, Germany...
3. Is the unit in a condition which does not represent any health threats for the staff of our service department? If not, which substances has the unit come into contact with? 4. Legally binding declaration The customer is aware of being legally liable to WIGGENS Instruments for any damages arising from incomplete and incorrect information. Date Signature...
Need help?
Do you have a question about the WS-350R and is the answer not in the manual?
Questions and answers