Advertisement

Quick Links

English
OPERATING MANUAL
TM-Series Vortex Shaker
Vortex TM-1/TM-1F/TM-2/TM-2F
WIGGENS GmbH
Gässlesweg 22-24, 75334 Straubenhardt,
Germany
Tel.: 0049 7248 4529088
Wiggens Co., Ltd.
Room 426, Hall A, Office Building M8, No.1
Jiuxianqiao East Road, Chaoyang District,
Beijing 100015, China
Tel: +86 400-809-2068
Fax: +86 400-809-2068-112
info@ wiggens.com
www.wiggens.com
1.36011.0403.20-V2.1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TM Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Wiggens TM Series

  • Page 1 TM-Series Vortex Shaker Vortex TM-1/TM-1F/TM-2/TM-2F WIGGENS GmbH Gässlesweg 22-24, 75334 Straubenhardt, Germany Tel.: 0049 7248 4529088 Wiggens Co., Ltd. Room 426, Hall A, Office Building M8, No.1 Jiuxianqiao East Road, Chaoyang District, Beijing 100015, China Tel: +86 400-809-2068 Fax: +86 400-809-2068-112 info@ wiggens.com...
  • Page 2: Unpacking And Inspecting

    Congratulations! You have made an excellent choice. WIGGENS thanks you for the trust you have placed in us. This operating manual has been designed to help you gain an understanding of the operation and possible applications of our instruments. For optimal utilization of all functions, we recommend that you thoroughly study this manual prior to beginning operation.
  • Page 3: Table Of Contents

    4.4.2. When Using Flat Attachment ..................... 16 4.4.3 When using test-tube attachment ..................17 4.4.4 When Using Micro-plate Attachment .................. 17 4.5. Operation of the TM Series shaker with Stirrer platform ............18 5. Cleaning and Maintenance ......................... 19 5.1. Routine Cleaning ........................19 5.2.
  • Page 4: Intended Use

    Operating Manual 1. Intended Use The WIGGENS TM-1/ TM-1F / TM-2/ TM-2F is an elaborate vortex shaker constructed for safe and reliable shaking tasks. These are general purpose laboratory vortex mixers with micro-processor feedback, and are designed to perform a wide variety of tasks.
  • Page 5: Disposal

    WIGGENS TM-1/1F/2/2F  Routine operation can also be carried out by untrained personnel who should however be instructed by trained personnel. If you have any questions concerning the operation of your instrument or the information in this manual, please contact 2.1.
  • Page 6: Technical Specifications

    Full Order Numbers (FON), consisting of the BON followed by the ONA. For a full explanation of the ONA of your product, please ask your local WIGGENS support or refer to the Order Number Guide in the WIGGENS General Catalog.
  • Page 7: Safety Instructions

    WIGGENS TM-1/1F/2/2F 3. Safety Instructions 3.1. Explanation of Safety Notes In addition to the safety warnings listed, warnings are posted throughout the operating manual. These warnings are designated by an exclamation mark inside an equilateral triangle. “Warning of a dangerous situation (Attention! Please follow the documentation).”...
  • Page 8: For Your Protection

    Operating Manual 3.2. For Your Protection  Make sure you read and understand all instructions and safety precautions listed in this manual before installing or operating your instrument.  Keep the operation instructions in a place where they can be accessed by everyone. ...
  • Page 9 WIGGENS TM-1/1F/2/2F  Beware of hazards due to: - Flammable materials - Container breakage - Incorrect container size - Overfilling of media - Unsafe condition of container.  Process pathogenic materials only in closed vessels under a suitable extractor hood.
  • Page 10: For Protection Of The Equipment

    Operating Manual 3.3. For protection of the equipment  You have received a product designed for industrial and experimental use. Nevertheless, avoid strikes to the housing, vibrations, damage to the operating-element panel, and contamination.  Make sure that the mains power supply has low impedance to avoid any negative effects on instruments being operated on the same mains.
  • Page 11: Operating Procedures

     4.2. Installation 4.2.1. Installing the TM Series vortex shaker  Place the unit on a level, stable surface near a grounded electrical power outlet. The surface should be clean and free of dust to ensure that the feet grip the surface firmly. Allow sufficient clearance on all sides of the unit for proper ventilation.
  • Page 12: Fixing & Changing Attachments

    Operating Manual 4.2.2. Fixing & Changing Attachments Note! All WIGGENS TM series vortex shaker have a standard attachment when shipped. Other attachments can be ordered separately as options Note! When using the universal tray and test tube platform, in order to avoid severe vibration...
  • Page 13: Mounting Of All Attachments (Except Stirrer Platform Base)

    WIGGENS TM-1/1F/2/2F 4.2.3. Mounting of all attachments (except stirrer platform base) 1. The standard round base and Microtiter plate base attachments have a 3-connector on the underside 2. Align the –connector along the 3-pin on the tube-mixer units. The 3-pin and 3-connector are designed to be fitted in one way only.
  • Page 14 Operating Manual 4.2.4. Mounting of the stirrer platform Base 1. The under-side of the stirrer platform base is designed to fit in one direction only. 2. Align the stirrer platform base along with the insert guide on the unit. 3. Push the stirrer platform base downward firmly and twist it clockwise. Ensure that you hear an affirmative “click” sound.
  • Page 15: Overview Of The Tm Series Vortex Shakers

    WIGGENS TM-1/1F/2/2F 4.3. Overview of the TM Series vortex shakers 1.rubber platform 2.ON/TOUCH switch 3. dial knob 4.main switch Back View Power cord connection TM-1 TM-2 The difference between TM-1and TM-2...
  • Page 16: Operation Of The Tm Series Shaker With Test-Tube

    Operating Manual 4.4. Operation of the TM Series shaker with Test-tube All operating controls are located on the front panel. The power switch (ON/OFF) is located on the right side. The “TOUCH” and continuously mode “ON” switch can be used alternatively for this purpose.
  • Page 17: When Using Test-Tube Attachment

    WIGGENS TM-1/1F/2/2F 4.4.3 When using test-tube attachment 1. Check that the power is off. 2. When fixing the tube attachment base, ensure that you heard an affirmative ‘click’ sound. This shows that it is firmly securely to the unit. 3. Turn the dial knob anti-clockwise to the minimum level. Power the unit ON.
  • Page 18: Operation Of The Tm Series Shaker With Stirrer Platform

    If too much force is applied to the top plate, the unit pauses temporarily as a safety feature 4.5. Operation of the TM Series shaker with Stirrer platform 1. Check that the power is off.
  • Page 19: Cleaning And Maintenance

    Wipe the housing of the instrument with a damp cloth using a mild soap and water solution. Cleaning For cleaning disconnect the main plug. Only use cleansing agents which have been recommended by WIGGENS Use to remove: Dyes isopropyl alcohol...
  • Page 20: Maintenance

    Operating Manual 5.2. Maintenance Do not attempt to service or repair a WIGGENS homogenizer. If the homogenizer’s housing is opened the warranty becomes void. Contact WIGGENS for return authorization and return instructions. Ordering spare parts When ordering spare parts, please give:...
  • Page 21: Service

    Defective dial knob. Return unit. Contact dealer or refer to section guidelines for returning units for repair. Note! WIGGENS reserves the right to carry out technical modification swith repairs for providing improved performance of the instrument 7.2. Warranty WIGGENS In accordance with warranty conditions, the warranty period is 24 months.
  • Page 22: Contact /Technical Service

    Our contact details WIGGENS GmbH Add:Gässlesweg 22-24, 75334 Straubenhardt, Germany Tel.: 0049 7248 4529088 Wiggens Co., Ltd. Room 426, Hall A, Office Building M8, No.1 Jiuxianqiao East Road, Chaoyang District, Beijing 100015, China Tel: +86 400-809-2068 Fax: +86 400-809-2068-112 info@ wiggens.com service@wiggens.com...
  • Page 23: Confirmation Of Condition Of Unit

    WIGGENS TM-1/1F/2/2F Confirmation of condition of unit WIGGENS In the case of repair, copy and complete the Conformation of condition of unit and send it to Instruments. 1. Details about the unit Product number Serial number Reason for repair 2. Has the device been cleaned, decontaminated/sterilized? 3.
  • Page 24 Operating Manual WIGGENS GmbH Gässlesweg 22-24, 75334 Straubenhardt, Germany Tel.: 0049 7248 4529088 WIGGENS China Room 426, Hall A, Office Building M8, No.1 Jiuxianqiao East Road, Chaoyang District, Beijing 100015, China Tel: +86 400-809-2068 Fax: +86 400-809-2068-112 info@ wiggens.com www.wiggens.com...

This manual is also suitable for:

Tm-1Tm-1fTm-2Tm-2f

Table of Contents