Summary of Contents for Panasonic KX-TDA600 - Hybrid IP PBX Control Unit Max. 1008 Ports
Page 1
KX-TDA50/KX-TDA100 Model No. KX-TDA200/KX-TDA600 Thank you for purchasing a Panasonic Hybrid IP-PBX. Please read this manual carefully before using this product and save this manual for future use. KX-TDA50: PSMPR Software File Version 5.0000 or later KX-TDA100/KX-TDA200: PMPR Software File Version 5.0000 or later KX-TDA600: PLMPR Software File Version 5.0000 or later...
Page 2
Introduction About this Programming Manual The PT Programming Manual is designed to serve as a reference to programming the Panasonic Hybrid IP-PBX using a Panasonic proprietary telephone (PT) with display. The PT Programming Manual is divided into the following sections: Section 1, Overview Provides an overview of programming the PBX.
Page 3
Unplug the PBX from the AC outlet if it emits smoke, an abnormal smell or makes unusual noise. These conditions can cause fire or electric shock. Confirm that smoke has stopped and contact an authorized Panasonic Factory Service Center. NOTES •...
Page 5
Table of Contents [321] ARS Leading Number ..................27 [322] ARS Routing Plan Table Number ...............27 [325] ARS Exception Number ..................28 [330] ARS Routing Plan Time Table ................28 [331–346] ARS Routing Plan Table (1–16) (KX-TDA50/KX-TDA100/KX-TDA200 only) ..........................28 [347] ARS Routing Plan Table (1–48) (KX-TDA600 only) ...........28 [350] ARS Carrier Name ....................29 [351] ARS Trunk Group for Carrier Access ..............29 [352] ARS Removed Number of Digits for Carrier Access ..........29...
Page 6
Table of Contents [602] Class of Service ....................37 [603] Extension User Group ..................37 [604] Extension Intercept Destination ................38 [605] Call Forwarding—No Answer Time ..............38 [606] CLIP Number ......................38 [620] Incoming Call Distribution Group Member ............38 [621] Incoming Call Distribution Group Delayed Ringing ..........38 [622] Incoming Call Distribution Group Floating Extension Number ......39 [623] Incoming Call Distribution Group Name .............39 [624] Incoming Call Distribution Group Distribution Method ........39...
These programming instructions are designed to serve as an overall system programming reference for the Panasonic Hybrid IP-PBX. Each feature in the PBX has default settings that can be changed to customize the PBX to your requirements. These settings control the functions of the PBX, and changing them is referred to as "system programming".
1.1.2 Password Security 1.1.2 Password Security To maintain system security, system passwords are required to access certain programming functions of the PBX. By giving different users access to different passwords, it is possible to control the amount of programming that each user is able to perform. The following types of system passwords are available: Password Description...
1.1.3 Entering Characters 1.1.3 Entering Characters The following characters can be used when storing a name, message, or other text entry data using a PT. The tables below show you the characters available by pushing each button a specific number of times. Table 1 (Standard mode) Table 2 (Option mode) PT Programming Manual...
Page 13
1.1.3 Entering Characters [Example of Entering Characters] To enter "Ann": (5 times) (5 times) FWD/DND Note • To erase the character on the cursor, press CLEAR. • To move the cursor to the left, press • To move the cursor to the right, press .
Section 2 PT Programming This section serves as reference operating instructions when using a display PT to program the PBX. Document Version 2008-11 PT Programming Manual...
2.1.1 Programming Instructions 2.1 PT Programming 2.1.1 Programming Instructions Required Telephone/Extension PBX settings can be customized through system programming by using a proprietary telephone (PT) with a multiline display, such as the KX-NT343 or KX-DT346. To access system programming, the Class of Service (COS) assigned to the PT’s extension must be programmed to allow system programming, or the PT must be connected to the lowest-numbered port on the card installed in the lowest-numbered slot.
Page 17
2.1.1 Programming Instructions Fixed Buttons Function KX-NT300/KX-DT300 KX-NT136/KX-T7600 KX-T7200/KX-T7400 FLASH/ FLASH FLASH RECALL TRANSFER CLEAR TRANSFER INTERCOM SECRET INTERCOM The buttons shown in this column are from the KX-T7400 series. Entering System Programming Mode Using a PT to perform system programming allows an authorized extension user to set a wide range of PBX features and parameters.
2.1.2 Maximum Values Programming Programming Group Title Description Number TRS/ARS Programming TRS and Automatic Route Selection (ARS) [3XX] programming [4XX] CO Line Programming CO line and trunk group settings COS Programming Class of Service parameters [5XX] Extension Programming Extension feature settings [6XX] Resource/Interface Programming PBX interface and external device settings [7XX]...
Page 19
2.1.2 Maximum Values Slot Number Supported Cards 05–07 DLC8, PLC8, SLC8 cards 08–09 DPH4 card Enter slot numbers as two-digit numbers (e.g. "04" for slot 4). Available Port Entry Values Card Type Port Number Related Programming DLC4 01–04 HLC4 01–04 PLC4 01–04 [600] [601]...
2.1.3 Basic Programming [003] Extension Number [003] New Extn. No. Current Extn. No. 101– ENTER ENTER Note • Extension numbers of PSs can be a maximum of 4 digits. • If PC Phone, PC Console, or a CTI application is running on a PC connected to an extension whose extension number is to be programmed/modified, quit the application first.
2.1.4 System Management Programming Note This program is only available after the port connected to the DSS Console is assigned as "DSS Console" in [601] Terminal Device Assignment. If one or more SDN buttons have been set at the DSS Console, they must be deleted before this setting can be changed (KX-TDA100/KX-TDA200/KX-TDA600 only).
2.1.4 System Management Programming [102] Time Service Starting Time [102] Day No. Time No. 0 Sun/1 Mon/ 1 Day-1/2 Lunch/ ENTER 2 Tue/3 Wed/ 3 Day-2/4 Night 4 Thu/5 Fri/6 Sat Hour:Minute SELECT 01:00–12:59 AM/PM ENTER To the Next Time No. To the Next Day No.
2.1.4 System Management Programming [120] Verification Code [120] Location No. Verification Code 0001–1000 1–4 digits ENTER ENTER [121] Verification Code Name [121] Location No. Name 0001–1000 Max. 20 characters ENTER ENTER [122] Verification Code Personal Identification Number (PIN) [122] Location No. 0001–1000 Max.
2.1.5 Timer Programming 2.1.5 Timer Programming [200] Hold Recall Time [200] Time 0–240 s ENTER ENTER (HOLD) 60 s [201] Transfer Recall Time [201] Time 1–240 s ENTER ENTER 60 s [203] Intercept Time [203] Time No. Time No. Time 1 Day/2 Lunch 1–240 s ENTER...
2.1.6 TRS/ARS Programming [208] Call Duration Count Starting Time for LCOT [208] Time 0–60 s ENTER ENTER [209] DISA Delayed Answer Time [209] Time 0–30 s ENTER ENTER [210] DISA CO-to-CO Line Call Prolong Time [210] Time 0–7 min ENTER ENTER 3 min [211] DISA Intercept Time...
2.1.6 TRS/ARS Programming [325] ARS Exception Number [325] Location No. Exception No. 001–200 Max. 16 digits ENTER ENTER [330] ARS Routing Plan Time Table [330] Plan Table No. Day No. ARS Time No. KX-TDA50: 01–16 0 Sun/1 Mon/2 Tue/ 1 TimeA/2 TimeB/ ENTER KX-TDA100: 01–16 3 Wed/4 Thu/5 Fri/6 Sat...
2.1.7 CO Line Programming [350] ARS Carrier Name [350] Carrier Table No. Name KX-TDA50: 01–10 Max. 20 characters ENTER ENTER KX-TDA100: 01–10 KX-TDA200: 01–10 KX-TDA600: 01–48 [351] ARS Trunk Group for Carrier Access [351] Carrier Table No. Trunk Group No. SELECT SELECT Disable/...
2.1.7 CO Line Programming [401] LCOT CO Line Name [401] Name CO Line No. 3 digits Max. 20 characters ENTER ENTER [402] LCOT Trunk Group Number [402] Trunk Group No. CO Line No. 3 digits KX-TDA50: 01–64 KX-TDA100: 01–64 ENTER ENTER KX-TDA200: 01–64 KX-TDA600: 01–96...
2.1.7 CO Line Programming [413] LCOT CPC Signal Detection Time—Outgoing [413] Slot No. Port No. Mode No. 0: None/1: 6.5/ ENTER ENTER 2–113: (N–1)×8 ms 051 (400 ms) [414] LCOT CPC Signal Detection Time—Incoming [414] Mode No. Slot No. Port No. 0: None/1: 6.5/ ENTER 2–113: (N–1)×8 ms...
2.1.7 CO Line Programming [451] DID Number [451] Location No. DID No. 0001–1000 Max. 32 digits ENTER ENTER [452] DID Name [452] Location No. Name 0001–1000 Max. 20 characters ENTER ENTER [453] DID Destination [453] Time No. Location No. Destination No. 1 Day/2 Lunch/ 0001–1000 1–5 digits...
2.1.7 CO Line Programming [475] DISA Silence Detection [475] Trunk Group No. SELECT KX-TDA50: 01–64 No Detect/ ENTER ENTER KX-TDA100: 01–64 Detect KX-TDA200: 01–64 KX-TDA600: 01–96 [476] DISA Continuous Signal Detection [476] Trunk Group No. SELECT KX-TDA50: 01–64 No Detect/ ENTER ENTER KX-TDA100: 01–64...
2.1.8 COS Programming 2.1.8 COS Programming [500] Trunk Group Number [500] Time No. COS No. 1 Day/2 Lunch/ 01–64 ENTER 3 Break/4 Night Trunk Group No. SELECT (AUTO ANS/MESSAGE) KX-TDA50: 01–64 Disable/ Enable ENTER (HOLD) KX-TDA100: 01–64 KX-TDA200: 01–64 KX-TDA600: 01–96 To the Next To the Next Trunk Group...
2.1.8 COS Programming [505] Executive Busy Override [505] COS No. SELECT Disable/ 01–64 ENTER ENTER Enable [506] Executive Busy Override Deny [506] COS No. SELECT Disable/ 01–64 ENTER ENTER Enable [507] DND Override [507] COS No. SELECT Disable/ 01–64 ENTER ENTER Enable [508] Account Code Mode...
2.1.8 COS Programming [512] Permission for Door Open Access [512] COS No. SELECT Disable/ 01–64 ENTER ENTER Enable [514] Time Service Manual Switching [514] COS No. SELECT Disable/ 01–64 ENTER ENTER Enable [515] Wireless XDP Parallel Mode for Paired Telephone [515] COS No.
2.1.9 Extension Programming 2.1.9 Extension Programming [600] EXtra Device Port (XDP) Mode [600] Slot No. Port No. SELECT (AUTO ANS/MESSAGE) Off/On (HOLD) ENTER ENTER To the Next Port No. To the Desired Port No. NEXT CANCEL [601] Terminal Device Assignment [601] Slot No.
2.1.9 Extension Programming [604] Extension Intercept Destination [604] Time No. Extn. No. Destination No. Max. 32 digits 1 Day/2 Lunch/ ENTER ENTER 3 Break/4 Night [605] Call Forwarding—No Answer Time [605] Extn. No. Time 0–120 s ENTER ENTER 15 s [606] CLIP Number [606] Extn.
2.1.9 Extension Programming [622] Incoming Call Distribution Group Floating Extension Number Incoming Call [622] Extn. No. Distribution Group No. ENTER ENTER 001–128 [623] Incoming Call Distribution Group Name Incoming Call [623] Name Distribution Max. 20 characters Group No. ENTER ENTER 001–128 [624] Incoming Call Distribution Group Distribution Method Incoming Call...
2.1.9 Extension Programming [627] Destination When All Busy Incoming Call [627] Time No. Destination No. Distribution 1 Day/2 Lunch/ Max. 32 digits Group No. ENTER 3 Break/4 Night 001–128 ENTER [628] Queuing Call Capacity Incoming Call [628] Number in Queuing Distribution 0–30 Group No.
2.1.9 Extension Programming [632] Maximum Number of Agents Incoming Call [632] Number of Agents Distribution No Limitation/01–32 Group No. ENTER ENTER 001–128 [640] Extension User Groups of a Paging Group [640] Paging Group No. Extn. User Group No. KX-TDA50: 01–32 KX-TDA50: 001–032 ENTER KX-TDA100: 01–32...
2.1.9 Extension Programming [660] VM Group Floating Extension Number [660] VM (DPT) Group No. Extn. No. KX-TDA50: 1 KX-TDA50: 500 ENTER ENTER KX-TDA100: 1–2 KX-TDA100: Group 1=500 KX-TDA200: 1–2 KX-TDA200: Group 1=500 KX-TDA600: 1–8 KX-TDA600: Group 1=500 [680] Idle Extension Hunting Type [680] Hunting Group No.
2.1.10 Resource/Interface Programming [691] PS Termination [691] PS No. See below ENTER ENTER KX-TDA50: 001–028 KX-TDA100: 001–128 KX-TDA200: 001–128 KX-TDA600: 001–512 [692] Personal Identification Number (PIN) for PS Registration [692] PIN for PS Registration 4 digits ENTER ENTER 1234 [699] CS Status Reference [699] Slot No.
2.1.10 Resource/Interface Programming [710] Music Source Selection for BGM (with the KX-TDA50)/BGM2 (with the KX-TDA100/KX-TDA200/KX-TDA600) [710] SELECT (AUTO ANS/ MESSAGE) ENTER ENTER External/ Internal1/ Internal2 [711] Music on Hold [711] Music Source No. KX-TDA50: Tone/BGM ENTER ENTER KX-TDA100: Tone/BGM1–2 KX-TDA200: Tone/BGM1–2 KX-TDA600: Tone/BGM1–2 [712] Music for Transfer [712]...
2.1.12 Card Programming [804] SMDR Outgoing Call Printing [804] SELECT No print/ ENTER ENTER Print [805] SMDR Incoming Call Printing [805] SELECT No print/ ENTER ENTER Print [810] Remote Programming [810] SELECT Disable/ ENTER Enable ENTER [811] Modem Floating Extension Number [811] Extn.
2.1.12 Card Programming [901] Slot Card Deletion [901] Slot No. Delete Confirming the ENTER ENTER deleting operation. To the Next Slot No. To the Desired Slot No. NEXT CANCEL [902] Slot Card Reset [902] Slot No. Reset Confirming the ENTER ENTER resetting operation.
3.2 Feature Programming References Call Transfer • [201] Transfer Recall Time • [503] Call Transfer to CO Line • [712] Music for Transfer Feature Manual References 3.1.8 Call Transfer Caller ID • [001] System Speed Dialing Number • [002] System Speed Dialing Name •...
3.2 Feature Programming References Feature Manual References 3.1.20 CPC (Calling Party Control) Signal Detection CO Line Access • [400] LCOT CO Line Connection • [401] LCOT CO Line Name • [409] LCOT CO Line Number Reference • [500] Trunk Group Number Feature Manual References 3.1.14 CO Line Access CO Line Call Limitation...
3.2 Feature Programming References Feature Manual References 4.1.6 DIL (Direct In Line) DISA (Direct Inward System Access) • [209] DISA Delayed Answer Time • [210] DISA CO-to-CO Line Call Prolong Time • [211] DISA Intercept Time • [475] DISA Silence Detection •...
3.2 Feature Programming References Feature Manual References 8.1.6 Hot Line ICD Group Features • [620] Incoming Call Distribution Group Member • [621] Incoming Call Distribution Group Delayed Ringing • [622] Incoming Call Distribution Group Floating Extension Number • [623] Incoming Call Distribution Group Name •...
3.2 Feature Programming References Paging • [640] Extension User Groups of a Paging Group • [641] External Pagers of a Paging Group Feature Manual References 13.1.1 Paging Paralleled Telephone • [600] EXtra Device Port (XDP) Mode Feature Manual References 13.1.2 Paralleled Telephone Pause Insertion •...
3.2 Feature Programming References Private Network Features—PS Roaming by Network ICD Group • [620] Incoming Call Distribution Group Member • [622] Incoming Call Distribution Group Floating Extension Number • [624] Incoming Call Distribution Group Distribution Method Feature Manual References 13.1.17 Private Network Features—PS Roaming by Network ICD Group Private Network Features—QSIG—CLIP/COLP (Calling/Connected Line Identification Presentation) and CNIP/CONP (Calling/Connected Name Identification Presentation)
Page 62
3.2 Feature Programming References PT Programming • 2.1 PT Programming • [516] Programming Mode Limitation Feature Manual References 13.1.28 PT Programming Redial, Last Number • [205] Automatic Redial Repeat Times (KX-TDA100/KX-TDA200/KX-TDA600 only) Feature Manual References 15.1.1 Redial, Last Number SMDR (Station Message Detail Recording) •...
3.2 Feature Programming References TAFAS (Trunk Answer From Any Station) • [700] External Pager Floating Extension Number Feature Manual References 17.1.2 TAFAS (Trunk Answer From Any Station) Tenant Service • [001] System Speed Dialing Number • [006] Operator Assignment • [320] ARS Mode •...