The SDM630-Modbus V2 measures and displays the characteristics of single phase two wires (1p2w), three phase three wires (3p3w,) and three phase four wires(3p4w) supplies, including voltage, frequency, current, power, active and reactive energy, imported or exported. Energy is measured in terms of kWh, kVArh. Maximum demand current can be measured over preset periods of up to 60 minutes. In order to measure energy, the unit requires voltage and current inputs in addition to the supply required to power the product.
SDM630-Modbus V2 supports Max. 100A direct connection, saves the cost and avoid the trouble to connect external CTs, giving the unit a cost-effective and easy operation. Built-in interfaces provides pulse and RS485 Modbus RTU outputs. Configuration is password protected.
The Unit can measure and display:
The unit has password-protected set-up screens for:
Two pulse outputs indicates real-time energy measurement. An RS485 output allows remote monitoring from another display or a computer.
This uses an RS485 serial port with Modbus RTU protocol to provide a means of remotely monitoring and controlling the Unit.
Set-up screens are provided for setting up the RS485 port.
This provides two pulse outputs that clock up measured active and reactive energy. The constant of pulse output 2 for active energy is 400imp/kWh (unconfigurable), its width is fixed at 100ms. The default constant of configurable pulse output 1 is 400imp/kWh, default pulse width is 100ms. The configurable pulse output 1 can be set from the set-up menu.
After a short delay, the screen will display active energy measurements.
The buttons operate as follows:
Each successive pressing of the button selects a new range:
Each successive pressing of the button selects a new range:
Each successive pressing of the button select a new range:
Each successive pressing of the button selects a new range:
To enter set-up mode, pressing the button for 3 seconds, until the password screen appears.
Setting up is password-protected so you must enter the correct password (default '1000') before processing.
If an incorrect password is entered, the display will show: PASS Err
To exit setting-up mode, press repeatedly until the measurement screen is restored.
Some menu items, such as password, require a four-digit number entry while others, such as supply system, require selection from a number of menu options.
When setting up the unit, some screens require the entering of a number. In particular, on entry to the setting up section, a password must be entered. Digits are set individually, from left to right. The procedure is as follows:
Press to exit the number setting routine and return to the Set-up menu.
This sets the period in minutes over which the current and power readings are integrated for maximum demand measurement. The options are: 0, 5, 8, 10, 15, 20, 30, 60 minutes
Use and
buttons to select the time interval. Press
to confirm the set-up.
Use this section to set the type of electrical system.
Press to exit the system selection routine and return to the menu. You will be returned to the main Set-up Menu.
This option allows you to configure the pulse output 1. The output can be set to provide a pulse for a defined amount of energy active or reactive.
Use this section to set up the pulse output for:
Total kWh/ Total kVArh
Import kWh/Export kWh
Import KVArh/Export KVArh
Press to confirm the setting and press
to return to the main set up menu.
Use this to set the energy represented by each pulse. Rate can be set to 1 pulse per dFt/0.01/0.1/1/10/100kWh/kVArh.
(It shows 1 pulse = 10kWh/kVArh)
Use and
buttons to choose pulse rate. On completion of the entry procedure, press
to confirm the setting and press
to return to the main set up menu.
The energy monitored can be active or reactive and the pulse width can be selected as 200, 100(default) or 60ms.
(It shows pulse width of 200ms)
Use and
buttons to choose pulse width. On Completion of the entry procedure, press
to confirm the setting and press
to return to the main set -up menu.
There is a RS485 port can be used for communication using Modbus RTU protocol. For Modbus RTU, parameters are selected from Front panel.
(The range is from 001 to 247)
On completion of the entry procedure, press button to confirm the setting and press
button to return the main set-up menu.
On completion of the entry procedure, press to confirm the setting and press
to return to the main set-up menu.
On Completion of the entry procedure, press to confirm the setting and press
to return to the main set-up menu.
On completion of the entry procedure, press to confirm the setting and press
to return to the main set up menu.
Note: Default is 1, and only when the parity is NONE that the stop bit can be changed to 2.
The meter provides a function to reset the maximum demand value of current and power.
Press to confirm the setting and press
to return to the main set up menu.
The unit can monitor and display the following parameters of a single phase two wire(1p2w), three phase three wire(3p3w) or four phase four wire(3p4w) supply.
Phase to neutral voltages 100 to 276V a.c. (not for 3p3w supplies)
Voltages between phases 173 to 480V a.c. (3p supplies only)
Percentage total voltage harmonic distortion (THD%) for each phase to N ( not for 3p3w supplies)
Percentage voltage THD% between phases (three phase supplies only)
Current THD% for each phase
Frequency in Hz Instantaneous power:
Power 0 to 99999 W
Reactive Power 0 to 99999 VAr
Volt-amps 0 to 99999 VA
Maximum demanded power since last Demand reset Power factor
Maximum neutral demand current, since the last Demand reset (for 3p4w supply only)
Imported active energy | to 999999.99 kWh |
Exported active energy | to 999999.99 kWh |
Imported reactive energy | to 999999.99 kVArh |
Exported reactive energy | to 999999.99 kVArh |
Total active energy | to 999999.99 kWh |
Total reactive energy | to 999999.99 kVArh |
Voltage inputs through 4-way fixed connector with 25mm ² stranded wire capacity. single phase two wire(1p2w), three phase three wire(3p3w) or four phase four wire(3p4w) unbalanced. Line frequency measured from L1 voltage or L3 voltage.
Voltage | 0·5% of range maximum |
Current | 0·5% of nominal |
Frequency | 0·2% of mid-frequency |
Power factor | 1% of unity (0.01) |
Active power (W) | ±1% of range maximum |
Reactive power (VAr) | ±1% of range maximum |
Apparent power (VA) | ±1% of range maximum |
Active energy (Wh) | Class 1 IEC 62053-21 Class B EN50470-1/3 |
Reactive energy (VArh) | Class 2 IEC 62053-23 |
Response time to step input | 1s, typical, to >99% of final reading, at 50 Hz. |
Three interfaces are provided:
The Modbus configuration (Baud rate etc.) and the pulse output assignments (kW/kVArh, import/export etc.) are configured through the Set-up screens.
The unit provides two pulse outputs. Both pulse outputs are passive type.
Pulse output 1 is configurable. The pulse output can be set to generate pulses to represent total / import/export kWh or kVarh.
The pulse constant can be set to generate 1 pulse per:
dFt = 2.5 Wh/VArh 0.01 = 10 Wh/VArh
0.1 = 100 Wh/VArh
1 = 1 kWh/kVArh
10 = 10 kWh/kVArh
100 = 100 kWh/kVArh
Pulse width: 200/100/60ms
Pulse output 2 is non-configurable. It is fixed up with active kWh. The constant is 400imp/kWh.
For Modbus RTU, the following RS485 communication parameters can be configured from the Set-up menu:
Baud rate 2400, 4800, 9600, 19200, 38400
Parity none (default)/odd/even
Stop bits 1 or 2
RS485 network address nnn – 3-digit number, 001 to 247
Modbus™ Word order Hi/Lo byte order is set automatically to normal or reverse. It cannot be configured from the set-up menu.
Influence Quantities are variables that affect measurement errors to a minor degree. Accuracy is verified under nominal value (within the specified tolerance) of these conditions.
Ambient temperature | 23°C ±1°C |
Input frequency | 50Hz(MID) 50 or 60Hz ±2%(non-MID) |
Input waveform | Sinusoidal (distortion factor < 0·005) |
Magnetic field of external origin | Terrestrial flux |
Operating temperature | -25°C to +55°C*/ -40°C to +70°C* (optional) |
Storage temperature | -40°C to +70°C* |
Relative humidity | 0 to 90%, non-condensing |
Altitude | Up to 2000m |
Warm up time | 5S |
Vibration | 10Hz to 50Hz, IEC 60068-2-6, 2g |
Shock | 30g in 3 planes |
* Maximum operating and storage temperatures are in the context of typical daily and seasonal variation.
If you have any question, please feel free to contact our sales team.
Tel: 0086-573-83698881
Fax: 0086-573-83698883
email: sales@eastrongroup.com
Web: www.eastron.com.cn
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.
Advertisement
Need help?
Do you have a question about the SDM630-Modbus V2 and is the answer not in the manual?
Questions and answers