Download Print this page
Eastron SDM630-Mbus V2 User Manual

Eastron SDM630-Mbus V2 User Manual

Din rail smart meter for single and three phase electrical systems
Hide thumbs Also See for SDM630-Mbus V2:

Advertisement

Quick Links

EASTRON SDM630-Mbus V2 User Manual
SDM630-Mbus V2
DIN Rail Smart Meter for Single and Three Phase Electrical Systems
Measures kWh Kvarh, KW, Kvar, KVA, P,
F, PF, Hz, dmd, V, A, etc.
Bi-directional measurement IMP & EXP
Two pulse outputs
Mbus
Din rail mounting 35mm
100A direct connection
Better than Class 1 / B accuracy
EASTRON Germany @ B+G e-tech GmbH – Franz-Mehring Str. 36 – 01979 Lauchhammer
WEB: www.eastron-germany.de
Mail: info@bg-etech.de
USER MANUAL
2016 V1.2
Fax: +49 3574 4675519

Advertisement

loading

Summary of Contents for Eastron SDM630-Mbus V2

  • Page 1 Din rail mounting 35mm ⚫ 100A direct connection ⚫ Better than Class 1 / B accuracy USER MANUAL 2016 V1.2 EASTRON Germany @ B+G e-tech GmbH – Franz-Mehring Str. 36 – 01979 Lauchhammer WEB: www.eastron-germany.de Mail: info@bg-etech.de Fax: +49 3574 4675519...
  • Page 2 60 minutes. In order to measure energy, the unit requires voltage and current inputs in addition to the supply required to power the product. SDM630-Mbus V2 supports max. 100A direct connection, saves the cost and avoid the trouble to connect external CTs, giving the unit a cost-effective and easy operation. Built-in interfaces provides pulse and Mbus outputs.
  • Page 3 In Set-up Mode, this is the “Down” button Select the Energy display screens In Set-up mode, this is the “Enter” or “Right” button EASTRON Germany @ B+G e-tech GmbH – Franz-Mehring Str. 36 – 01979 Lauchhammer - 2 - WEB: www.eastron-germany.de Mail: info@bg-etech.de...
  • Page 4 Phase to neutral voltages(3p3w) Current on each phase Phase to neutral voltage THD%(3p4w) Phase to neutral voltage THD%(3p3w) EASTRON Germany @ B+G e-tech GmbH – Franz-Mehring Str. 36 – 01979 Lauchhammer - 3 - WEB: www.eastron-germany.de Mail: info@bg-etech.de Fax: +49 3574 4675519...
  • Page 5 Frequency and Power Factor (total) Power Factor of each phase Maximum Power Demand Maximum Current Demand EASTRON Germany @ B+G e-tech GmbH – Franz-Mehring Str. 36 – 01979 Lauchhammer - 4 - WEB: www.eastron-germany.de Mail: info@bg-etech.de Fax: +49 3574 4675519...
  • Page 6 Energy Measurements Each successive pressing of the button selects a new range: Imported active energy in kWh EASTRON Germany @ B+G e-tech GmbH – Franz-Mehring Str. 36 – 01979 Lauchhammer - 5 - WEB: www.eastron-germany.de Mail: info@bg-etech.de Fax: +49 3574 4675519...
  • Page 7 Imported reactive energy in kVArh Exported reactive energy in kVArh Total active energy in kWh Total reactive energy in kVArh EASTRON Germany @ B+G e-tech GmbH – Franz-Mehring Str. 36 – 01979 Lauchhammer - 6 - WEB: www.eastron-germany.de Mail: info@bg-etech.de...
  • Page 8 The SET indicator will be removed and you will be able to use the buttons for further menu selection. EASTRON Germany @ B+G e-tech GmbH – Franz-Mehring Str. 36 – 01979 Lauchhammer - 7 - WEB: www.eastron-germany.de Mail: info@bg-etech.de...
  • Page 9 The next digit will flash. EASTRON Germany @ B+G e-tech GmbH – Franz-Mehring Str. 36 – 01979 Lauchhammer - 8 - WEB: www.eastron-germany.de Mail: info@bg-etech.de Fax: +49 3574 4675519...
  • Page 10 The current time interval will flash buttons to select the time required. EASTRON Germany @ B+G e-tech GmbH – Franz-Mehring Str. 36 – 01979 Lauchhammer - 9 - WEB: www.eastron-germany.de Mail: info@bg-etech.de Fax: +49 3574 4675519...
  • Page 11 From the Set-up menu, use buttons to select the System option. The screen will show the currently selected power supply. EASTRON Germany @ B+G e-tech GmbH – Franz-Mehring Str. 36 – 01979 Lauchhammer - 10 - WEB: www.eastron-germany.de Mail: info@bg-etech.de...
  • Page 12 Import kWh/Export kWh Import KVArh/Export KVArh From the Set-up menu, use buttons to select the Pulse output option. EASTRON Germany @ B+G e-tech GmbH – Franz-Mehring Str. 36 – 01979 Lauchhammer - 11 - WEB: www.eastron-germany.de Mail: info@bg-etech.de Fax: +49 3574 4675519...
  • Page 13 The current setting will flash. Note: When it’s dFt, it means 2.5Wh/VArh EASTRON Germany @ B+G e-tech GmbH – Franz-Mehring Str. 36 – 01979 Lauchhammer - 12 - WEB: www.eastron-germany.de Mail: info@bg-etech.de Fax: +49 3574 4675519...
  • Page 14 EASTRON Germany @ B+G e-tech GmbH – Franz-Mehring Str. 36 – 01979 Lauchhammer - 13 - WEB: www.eastron-germany.de Mail: info@bg-etech.de Fax: +49 3574 4675519...
  • Page 15 It ranges from 00 00 00 01 to 99 99 99 99 On completion of the entry procedure, press button to confirm the setting and press EASTRON Germany @ B+G e-tech GmbH – Franz-Mehring Str. 36 – 01979 Lauchhammer - 14 - WEB: www.eastron-germany.de Mail: info@bg-etech.de...
  • Page 16 Parity From the Set-up menu, use buttons to select the Parity option. EASTRON Germany @ B+G e-tech GmbH – Franz-Mehring Str. 36 – 01979 Lauchhammer - 15 - WEB: www.eastron-germany.de Mail: info@bg-etech.de Fax: +49 3574 4675519...
  • Page 17 Stop Bit (2 or 1) On completion of the entry procedure, press to confirm the setting and press EASTRON Germany @ B+G e-tech GmbH – Franz-Mehring Str. 36 – 01979 Lauchhammer - 16 - WEB: www.eastron-germany.de Mail: info@bg-etech.de...
  • Page 18 The MD will flash. Press to confirm the setting and press to return to the main set up menu. EASTRON Germany @ B+G e-tech GmbH – Franz-Mehring Str. 36 – 01979 Lauchhammer - 17 - WEB: www.eastron-germany.de Mail: info@bg-etech.de...
  • Page 19 Voltage inputs through 4-way fixed connector with 25mm² stranded wire capacity. single phase two wire(1p2w), three phase three wire(3p3w) or four phase four wire(3p4w) unbalanced. Line frequency measured from L1 voltage or L3 voltage. EASTRON Germany @ B+G e-tech GmbH – Franz-Mehring Str. 36 – 01979 Lauchhammer - 18 - WEB: www.eastron-germany.de Mail: info@bg-etech.de...
  • Page 20 Baud rate 300, 600, 1200, 2400, 4800, 9600 Parity none (default)/odd/even Stop bits 1 or 2 MBus network primary address nnn – 3-digit number, 001 to 250 EASTRON Germany @ B+G e-tech GmbH – Franz-Mehring Str. 36 – 01979 Lauchhammer - 19 - WEB: www.eastron-germany.de Mail: info@bg-etech.de...
  • Page 21 Altitude Up to 2000m ⚫ Warm up time ⚫ Vibration 10Hz to 50Hz, IEC 60068-2-6, 2g EASTRON Germany @ B+G e-tech GmbH – Franz-Mehring Str. 36 – 01979 Lauchhammer - 20 - WEB: www.eastron-germany.de Mail: info@bg-etech.de Fax: +49 3574 4675519...
  • Page 22 EASTRON SDM630-Mbus V2 User Manual Dimensions EASTRON Germany @ B+G e-tech GmbH – Franz-Mehring Str. 36 – 01979 Lauchhammer - 21 - WEB: www.eastron-germany.de Mail: info@bg-etech.de Fax: +49 3574 4675519...
  • Page 23 EASTRON SDM630-Mbus V2 User Manual Wiring diagram ⚫ Three Phase Three Wires: EASTRON Germany @ B+G e-tech GmbH – Franz-Mehring Str. 36 – 01979 Lauchhammer - 22 - WEB: www.eastron-germany.de Mail: info@bg-etech.de Fax: +49 3574 4675519...
  • Page 24 EASTRON SDM630-Mbus V2 User Manual ⚫ Three Phase Four Wires: EASTRON Germany @ B+G e-tech GmbH – Franz-Mehring Str. 36 – 01979 Lauchhammer - 23 - WEB: www.eastron-germany.de Mail: info@bg-etech.de Fax: +49 3574 4675519...
  • Page 25 EASTRON SDM630-Mbus V2 User Manual ⚫ Single Phase two Wires: ⚫ EASTRON Germany @ B+G e-tech GmbH – Franz-Mehring Str. 36 – 01979 Lauchhammer - 24 - WEB: www.eastron-germany.de Mail: info@bg-etech.de Fax: +49 3574 4675519...