021. BEACON TIME
Function: Sets the interval time between repeats of
the beacon message.
Available Values: OFF/1 ~ 255 sec
Default Setting: OFF
022. CONTEST NUMBER
Function: Selects the Contest Number "Cut" format
for imbedded contest number.
Available Values: 1290/AUNO/AUNT/A2NO/A2NT/
12NO/12NT
Default Setting: 1290
1290: Does not abbreviate the Contest Number
AUNO: Abbreviates to "A" for "One," "U" for "Two," "N"
for "Nine," and "O" for "Zero."
AUNT: Abbreviates to "A" for "One," "U" for "Two," "N"
for "Nine," and "T" for "Zero."
A2NO: Abbreviates to "A" for "One," "N" for "Nine," and
"O" for "Zero."
A2NT: Abbreviates to "A" for "One," "N" for "Nine," and
"T" for "Zero."
12NO: Abbreviates to "N" for "Nine" and "O" for "Zero."
12NT: Abbreviates to "N" for "Nine" and "T" for "Zero."
023. CW MEMORY 1
Function: Permits entry of the CW message for mes-
sage register 1.
Available Values: TEXT/MESSAGE
Default Setting: MESSAGE
TEXT:
You may enter the CW message from a
supplied FH-2 Remote Control Keypad.
MESSAGE: You may enter the CW message from
the CW keyer.
FT 9000D O
FH-2 SETUP G
M
M
024. CW MEMORY 2
Function: Permits entry of the CW message for mes-
sage register 2.
Available Values: TEXT/MESSAGE
Default Setting: MESSAGE
TEXT:
You may enter the CW message from a
supplied FH-2 Remote Control Keypad.
MESSAGE: You may enter the CW message from
the CW keyer.
025. CW MEMORY 3
Function: Permits entry of the CW message for mes-
sage register 3.
Available Values: TEXT/MESSAGE
Default Setting: MESSAGE
TEXT:
You may enter the CW message from a
supplied FH-2 Remote Control Keypad.
MESSAGE: You may enter the CW message from
the CW keyer.
026. CW MEMORY 4
Function: Permits entry of the CW message for mes-
sage register 4.
Available Values: TEXT/MESSAGE
Default Setting: MESSAGE
TEXT:
You may enter the CW message from a
supplied FH-2 Remote Control Keypad.
MESSAGE: You may enter the CW message from
the CW keyer.
027. CW MEMORY 5
Function: Permits entry of the CW message for mes-
sage register 5.
Available Values: TEXT/MESSAGE/COUNTUP
Default Setting: MESSAGE
TEXT:
You may enter the CW message from a
supplied FH-2 Remote Control Keypad.
MESSAGE: You may enter the CW message from
the CW keyer.
M
Page 133

Hide quick links:

Advertisement

Table of Contents
loading