Advertisement

Quick Links

THERMO PRODUCTS USER MANUAL
UK
VIRNA IDRO.16
MADE
IN
ITALY
design & production
004330051 - REV.000

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VIRNA IDRO.16 and is the answer not in the manual?

Questions and answers

Summary of Contents for Extraflame VIRNA IDRO.16

  • Page 1 THERMO PRODUCTS USER MANUAL VIRNA IDRO.16 MADE ITALY design & production 004330051 - REV.000...
  • Page 2 APPLY TECHNICAL DATA LABEL...
  • Page 3: Table Of Contents

    FLUE DISCHARGE ....................................10 HYDRAULIC SYSTEM ..............................12 INSTALLATION AND SAFETY DEVICES ............................12 ANTI-CONDENSATION DEVICE (MANDATORY) ....................13 VIRNA IDRO.16 DETAILS ............................14 FEATURES ................................15 CHECKS AND MEASURES FOR COMMISSIONING ....................15 THE PELLET LOAD MOTOR DOES NOT FUNCTION: ........................15 BULB THERMOSTATS - REARM ................................15 STOVE POSITIONING .............................16...
  • Page 4: English

    ITALIANO ENGLISH FRANÇAIS ATTENZIONE TASSATIVO WARNING ATTENTION IMPÉRATIF PRIMA DI MOVIMENTARE LA STUFA BEFORE HANDLING THE STOVE, THE AVANT DE DÉPLACER LE POÊLE, TOGLIERE IL RIVESTIMENTO COVERING INDICATED MUST BE RE- RETIRER LE REVÊTEMENT INDIQUÉ INDICATO PER EVITARE DANNI. MOVED TO AVOID DAMAGE. POUR ÉVITER TOUT DOMMAGE.
  • Page 5: Warnings

    We thank you for having chosen our company; our product is a great heating solution developed from the most advanced technology with top quality machining and modern design, aimed at making you enjoy the fantastic sensation that the heat of a flame gives, in complete safety. WARNINGS This instructions manual is an integral part of the product: make sure that it always accompanies the appliance, even if transferred to another owner...
  • Page 6 RECEIVED INSTRUCTIONS ON SAFE USE OF THE APPLIANCE AND THAT THEY UNDERSTAND THE INHERENT DANGERS. Š THE GENERATOR MUST NOT BE USED BY PERSONS (INCLUDING CHILDREN) WITH REDUCED PHYSICAL, SENSORY AND MENTAL CAPACITIES OR WHO ARE UNSKILLED PERSONS, UNLESS THEY ARE SUPERVISED AND TRAINED REGARDING USE OF THE APPLIANCE BY A PERSON RESPONSIBLE FOR THEIR SAFETY.
  • Page 7: Routine Maintenance

    THAT SWITCH THE GENERATOR OFF. IF THIS OCCURS, CONTACT THE TECHNICAL AFTER-SALES SERVICE AND ALWAYS DISABLE THE SAFETY SYSTEMS. Š IN THE EVENT THE FLUE CATCHES FIRE, USE SUITABLE SYSTEMS FOR SUFFOCATING THE FLAMES OR REQUEST HELP FROM THE FIRE BRIGADE.
  • Page 8: Hermetically Sealed Installation

    HERMETICALLY SEALED INSTALLATION Virna Idro is a fully sealed product with respect to the environment in which it is installed. This means that it is ideal for passive houses because it does not take air in from within the house. COMBUSTION AIR To ensure the stove remains hermetically sealed, the connection pipe for the combustion air must be directly connected to the exterior, using special pipes and sealed connectors.
  • Page 9: Installation

    INSTALLATION GENERAL The support surfaces and/or points must have a suitable load-bearing capacity to support the weight of the appliance, of the accessories and coatings. The generator must be on the level for correct operation. The flue extraction and hydraulic connections must be carried out by qualified personnel who must issue documentation of conformity according to the regulations of the country of installation.
  • Page 10: Ventilation And Aeration Of The Installation Premises

    VENTILATION AND AERATION OF THE INSTALLATION PREMISES Ventilation, in the case of a non-watertight generator and/or non-watertight installation, must be carried out respecting the minimum area indicated below (considering the largest of the values suggested: Percentage of the Minimum net opening value of the Appliance categories Reference standard net opening section with respect to the...
  • Page 11 SHARED CHIMNEY FLUE Check on the CE Technical Data Sheet whether the product is suitable for installation in a shared chimney flue (i.e. with multiple connection). Suitable devices can be installed in shared flue systems provided that: Š installation in a shared chimney flue (i.e. with multiple connection) is allowed in the place of installation; Š...
  • Page 12: Hydraulic System

    HYDRAULIC SYSTEM Certain concepts referring to the Italian Standard UNI 10412-2 (2009) are described in this chapter. As previously described, when installing, all national, regional, provincial and council Standards in force provided by the country in which the appliance has been installed must be complied with. During installation of the generator it is MANDATORY to adjust the system with a manometer in order to display the water pressure.
  • Page 13: Distances Of Safety Devices According To The Standard

    DISTANCES OF SAFETY DEVICES ACCORDING TO THE STANDARD The temperature safety sensors must be in place on the machine at a distance no greater than 30 cm from the flow connection. Whenever the generators lack a device, those missing can be installed on the generator flow pipe, within a distance no greater than 1 m from the machine. COMMISSIONING CHECKS Before connecting the boiler: a) wash all system piping thoroughly in order to remove any residues which might compromise the correct functioning of certain system...
  • Page 14: Virna Idro.16 Details

    VIRNA IDRO.16 DETAILS Heat exchanger scrapers Display External door handle Pellet hopper pressurised closure Upper fumes exhaust Lower fumes exhaust Lateral fumes exhaust Combustive air rear inlet On/Off Power supply 230V Fuse Combustive air side inlet HYDRAULIC INSTALLATION 3 bar safety drain...
  • Page 15: Features

    FEATURES Water content of the thermo-product heat exchanger (l) Volume of expansion vessel integrated into thermo-product (l) 3 bar safety valve integrated into the thermo-product Minimum and maximum pressure switch integrated into the thermo-product PWM Pump integrated into the thermo-product Pump max.
  • Page 16: Stove Positioning

    STOVE POSITIONING To ensure the stove works correctly, it should always be positioned so that it is perfectly level, using a spirit level. NOTE FOR CORRECT OPERATION Pellet hopper lid The following indications must be respected for correct pellet stove operation: Both during the functioning and when the stove is not in use, all the machine doors (pellet hopper, fire door, ash drawer) must always remain closed.
  • Page 17: Pellets And Loading

    PELLETS AND LOADING Pellets are made by subjecting wood shavings i.e. the rejects of pure unpainted wood from sawmills, carpentry products and products from other activities connected to wood working and transformation, to very high pressures. This type of fuel is fully ecological as no glues are used for its compaction. In fact, pellet compactness is guaranteed over time by a natural substance found in wood: lignin.
  • Page 18: Control Board

    CONTROL BOARD VIEWING OF VARIOUS TO ACCESS ON/OFF TEXT MESSAGES THE MENU BUTTON OPERATING POWER TEMPERATURE ICON KEY Indicates the presence of an alarm. Indicates the weekly programming status Off: indicates there are no alarms Off: deactivated. On: indicates the presence of an alarm On: activated.
  • Page 19: General Menu

    GENERAL MENU Go back - exit Scroll parameters: next (2); previous (3) Modify data settings: increase (4); decrease (5) Confirm - access menu EASY SETUP CHRONO ENABLING PRG1 PRG2 SETTINGS DATE-TIME PRG3 LANGUAGE PRG4 DISPLAY STAND-BY FIRST LOAD OUTLET AIR DEGREES RESET *STOVE STATUS...
  • Page 20: Remote Control

    REMOTE CONTROL The remote control allows you to adjust all the functions that are normally possible with the LCD display. The various functions are outlined in detail in the table below: ON/OFF Prolonged pressure turns the stove on or off. POWER INCREASE Increases operating power POWER DECREASE...
  • Page 21: Commissioning Settings

    COMMISSIONING SETTINGS After connecting the power cord at the back of the generator, turn the switch (if any) to position (I). The switch is used to power the heat generator board. DATE-TIME This menu allows the date and time to be set. CONTROLS PROCEDURE Š...
  • Page 22: Operation And Logic

    OPERATION AND LOGIC IGNITION Once the points listed previously have been checked, press key 1 for three seconds to ignite the stove. 15 minutes are available for the ignition phase. After ignition and having reached the control temperature, the stove interrupts the ignition phase and passes to STARTING. PREPARATION During the start-up phase, the stove stabilises combustion, increasing it progressively, to then start ventilation and pass on to WORK.
  • Page 23: Additional Thermostat

    ADDITIONAL THERMOSTAT N.B. : INSTALLATION MUST BE PERFORMED BY AN AUTHORISED TECHNICIAN There is a possibility to control the temperature of a room adjacent to the room where the stove has been placed; simply connect a thermostat following the procedure described in the following section (it is advisable to place the optional mechanical thermostat at a height from the ground equal to 1.50m).
  • Page 24: Easy Setup

    EASY SETUP The volumetric weight of the pellet is the ratio between the weight and the volume of the pellet. This ratio may change while keeping the quality of the pellet unchanged. By using the EASY SETUP function, it is possible to dose the pellets by increasing or decreasing the preset values.
  • Page 25: Enabling/Disabling The Chrono

    ENABLING/DISABLING THE CHRONO CONTROLS PROCEDURE Š Press key 6. Š Press key 3 until CHRONO appears and confirm by pressing key 6. Š Confirm ENABLING with key 6. Š Use keys 4 and 5 for enabling (ON) or disabling OFF) Š...
  • Page 26 EXAMPLE OF CHRONO OVERLAPPING TIME/SLOTS Time slot 02:00 02:00 08:00 08:00 16:30 16:30 23:00 23:00 Set power 02:00 02:00 08:00 08:00 16:30 16:30 23:00 23:00 Set temperature 72° 72° 68° 68° 02:00 02:00 08:00 08:00 16:30 16:30 23:00 23:00 start 02:00 Time slot 1 power 3 - set temp 72°C stop 23:00...
  • Page 27: Settings

    SETTINGS • DATE-TIME • LANGUAGE SEE CHAPTER: COMMISSIONING SETTINGS. • SET DEGREES DISPLAY This menu allows you to adjust the brightness of the display. The values range from OFF, 1 to 20. If set to OFF, the display backlighting is set to maximum brightness and then, turns off after a 60 second delay.
  • Page 28: Outlet Air

    OUTLET AIR This function allows any air in the stove to be discharged. By activating the pump function, it will be powered alternatively with 30 second work phases and 30" stop for 15 minutes. With the stove cold and in "OFF", activate the OUTLET AIR function, pressing key 6 to confirm. To interrupt, press and hold key 1 for 3 seconds.
  • Page 29: Cleaning And Maintenance

    TO FIND OUT WHERE YOUR NEAREST SERVICE CENTRE IS, CONTACT YOUR DEALER OR GO TO THE WEBSITE: WWW.LANORDICA-EXTRAFLAME.COM CLEANING AND MAINTENANCE ALWAYS FOLLOW THE INSTRUCTIONS IN COMPLETE SAFETY! Š Make sure that the power cord is unplugged because the generator may have been programmed to switch on.
  • Page 30: Combustion Chamber

    BURN POT COMBUSTION CHAMBER: Š Remove the pellet chute assembly completely, emptying any ash reside from the burn pot below. Š Remove the burn pot, emptying any ash residue from the ash drawer below. Š Suck the ash of the combustion chamber and spark-plug pipe holder.
  • Page 31 CLEANING THE COMBUSTION CHAMBER DEFLECTOR Remove the deflector and eliminate the ash deposited in the upper part of the deflector. ENGLISH...
  • Page 32: Burn Pot Detail

    THE GASKETS FOR THE PELLET HOPPER, BURN POT AND FIRE DOOR ENSURE THAT THE STOVE WORKS PROPERLY. IT IS NECESSARY TO PERIODICALLY CHECK THEM; IF THEY SEEM TO BE WORN OR DAMAGED, THEY MUST BE REPLACED IMMEDIATELY. THESE OPERATIONS MUST BE CARRIED OUT BY A QUALIFIED TECHNICIAN. A CLEAN BURN POT GUARANTEES CORRECT OPERATION! BY MAKING SURE THE BURN POT AND ITS HOLES ARE ALWAYS CLEAN FROM ANY COMBUSTION RESIDUE, EXCELLENT COMBUSTION BY THE GENERATOR IS...
  • Page 33: Routine Maintenance Performed By Qualified Technicians

    PERSON, SO AS TO AVOID ALL RISKS. TO FIND OUT WHERE YOUR NEAREST SERVICE CENTRE IS, CONTACT YOUR DEALER OR GO TO THE WEBSITE: WWW.LANORDICA-EXTRAFLAME.COM ROUTINE MAINTENANCE PERFORMED BY QUALIFIED TECHNICIANS Routine maintenance must be performed at least once a year.
  • Page 34: Routine Maintenance

    ROUTINE MAINTENANCE THE IMAGES ARE FOR ILLUSTRATIVE PURPOSES ONLY. Fumes motor (disassembly and cleaning and fumes and "T" pipes), new silicone in the points envisioned Inspections of gaskets, pellet hopper, ash drawer and door (replace them and apply silicone where envisioned) Combustion chamber and heat exchanger (full cleaning) including ignition-plug pipe Hopper (complete emptying and cleaning) and check gasket.
  • Page 35 ROUTINE MAINTENANCE THE IMAGES ARE FOR ILLUSTRATIVE PURPOSES ONLY. Fumes motor (disassembly and cleaning and fumes and "T" pipes), new silicone in the points envisioned Inspections of gaskets, pellet hopper, ash drawer and door (replace them and apply silicone where envisioned) Combustion chamber and heat exchanger (full cleaning) including ignition-plug pipe Hopper (complete emptying and cleaning) and check gasket.
  • Page 36: Displays

    Check pellet feed (see “EASY SETUP”), if the problem cannot be solved, HOT FUMES High fumes temperature contact an authorised technician. TO FIND OUT WHERE YOUR NEAREST SERVICE CENTRE IS, CONTACT YOUR DEALER OR GO TO THE WEBSITE WWW.LANORDICA-EXTRAFLAME.COM ENGLISH...
  • Page 37 IPWM output interface damaged, in short Contact after-sales centre ALARM circuit or not connected * if there is an additional system data-sheet. TO FIND OUT WHERE YOUR NEAREST SERVICE CENTRE IS, CONTACT YOUR DEALER OR GO TO THE WEBSITE WWW.LANORDICA-EXTRAFLAME.COM ENGLISH...
  • Page 38: Disposal

    DISPOSAL INFORMATION FOR MANAGEMENT OF ELECTRIC AND ELECTRONIC APPLIANCE WASTE CONTAINING BATTERIES OR ACCUMULATORS This symbol, which is used on the product, batteries, accumulators or on the packaging or documents, means that at the end of its useful life, this product, the batteries and the accumulators included must not be collected, recycled or disposed of together with domestic waste. Improper management of electric or electronic waste or batteries or accumulators can lead to the leakage of hazardous substances contained in the product.
  • Page 39: Symbol En 16510-1

    Symbol EN 16510-1 EN 16510-1 EXPLANATION Symbol Nominal heat output part Part load heat output CON / INT Appliance operation, Continuos (CON) or Intermittent (INT) / CO Carbon dioxide emission 2 nom 2 part / CO Carbon monoxide emission part Minimum distances to combustible materials - bottom Minimum distances to combustible materials - ceiling Minimum distances to combustible materials - floor in front...
  • Page 40 EXTRAFLAME S.p.A. Via Dell’Artigianato, 12 36030 - MONTECCHIO PRECALCINO (VI) - ITALY   +39.0445.865911 -  +39.0445.865912 -  info@extraflame.it - www.lanordica-extraflame.com MADE ITALY design & production TO FIND THE SERVICE CENTRE NEAREST TO YOU CONTACT YOUR DEALER OR CONSULT THE SITE WWW.LANORDICA-EXTRAFLAME.COM...