MaINtENaNcE ....................................6 INStaLLatIoN ........................................7 MINIMUM DISTANCES .............................................. 7 PREPARATIONS FOR MAINTENANCE ........................................7 DEtaILS MarILENa pLuS aD ..................................9 SPACERS ..................................................10 Hot aIr DuctING ......................................10 ADDITIONAl ThERMOSTAT TO CONTROl ThE DUCT MOTOR ...............................10 poSItIoNING tHE StovE ..................................... 11 NotES for corrEct opEratIoN ................................
We thank you for having chosen our company; our product is a great heating solution developed from the most advanced technology with top quality machining and modern design, aimed at making you enjoy the fantastic sensation that the heat of a flame gives, in complete safety. Warnings This instructions manual is an integral part of the product: make sure that it always accompanies the appliance, even if transferred to another owner...
Page 5
CHILDREN) WITH REDUCED PHYSICAL, SENSORY AND MENTAL CAPACITIES OR WHO ARE UNSKILLED PERSONS, UNLESS THEY ARE SUPERVISED AND TRAINED REGARDING USE OF THE APPLIANCE BY A PERSON RESPONSIBLE FOR THEIR SAFETY. THE CLEANING AND MAINTENANCE REQUIRED BY THE USER MUST NOT BE PERFORMED BY CHILDREN WITHOUT SUPERVISION.
SYSTEMS. IN THE EVENT THE FLUE CATCHES FIRE, USE SUITABLE SYSTEMS FOR SUFFOCATING THE FLAMES OR REQUEST HELP FROM THE FIRE BRIGADE. THIS APPLIANCE MUST NOT BE USED TO BURN WASTE DO NOT USE ANY FLAMMABLE LIQUIDS FOR IGNITION ...
InstallatIOn general The flue gas exhaust and hydraulic connections must be carried out by qualified personnel who must issue installation conformity documentation compliant with national standards. The installer must provide the owner or person acting for him, according to the legislation in force, with the declaration of conformity, supplied with: 1) the use and maintenance manual of the appliance and of the system components (such as for example, the smoke ducts, chimney, etc.);...
Page 8
In the presence of type B gas appliances with intermittent operation not intended for heating, they must have their own aeration and/or ventilation opening. The air inlets must meet the following requirements: they must be protected with grids, metal mesh, etc., but without reducing the net useful section; ...
spACErs Behind the machine there are 2 spacers that delimit the minimum distance between the stove and anything behind it. The spacers must not be removed. Note: direct the room probe downwards or outwards of the stove. HOt AIr DuCtInG The hot air ducting pipe must have an internal diameter of 80 mm, it must be insulated or at least protected from heat dispersion.
pOsItIOnInG tHE stOvE For the correct operation of the product, we recommend positioning it on a perfectly flat surface. Use a spirit level to check this. nOtEs FOr COrrECt OpErAtIOn Pellet hopper lid For the correct operation of the pellet stove, the following indications must be respected: Both during the functioning and when the stove is not in use, all the machine doors (pellet hopper, fire door, ash drawer) must...
Pellets and loading Pellets are made by subjecting wood shavings i.e. the rejects of pure unpainted wood from sawmills, carpentry products and products from other activities connected to wood working and transformation, to very high pressures. This type of fuel is fully ecological as no glues are used for its compaction. In fact, pellet compactness is guaranteed over time by a natural substance found in wood: lignite.
Remote contRol The remote control can be used to adjust the main stove functions. Transmitter Select air mode Display Lock keyboard On/off stove (hold for 3 seconds) Degrees Celsius / Fahrenheit Set power Press the button once to enable or disable the chrono Set switch-off delay: The button allows to set the switch- off delay.
Remote contRol Icons Air mode selected: Enable chrono Flashing COMFORT Light on = activated On AUTO Light off = deactivated Indicates the transmission of the radio signal Set switch-off delay On = during all radio communication Off = radio communication absent Battery low Keys locked Set power level.
Control panel Display OF The variOUs TO aCCess BUTTON TexT messages The meNU ON/OFF aDJUsTiNg TemperaTUre OperaTiNg pOWer seTTiNgs Display iCon key indicates the reception of the radio signal Off: radio communication absent indicates the status of the additional thermostat input (gND - l3) On: radio communication present indicates the operation of the ducted motor indicates the status of the fumes motor.
Main Menu Back - exit scroll through parameters: next (3); previous (2) Change settings data: increase (4); decrease (5) Confirm - access menu FronT Air DUcTing EASY SETUP cHrono EnABLing Prg1 Prg2 SETTingS DATE-TimE Prg3 LAngUAgE Prg4 DiSPLAY STAnD-BY DELTA T FirST LoAD DEgrEES rESET...
settings for first use After connecting the power cord at the back of the stove, turn the switch located at the back to position (i). The switch at the back of the stove is used to power the generator board. The stove will remain off and the word oFF will appear on the panel.
operation anD logiC ignition after checking the previous points, press the 1 for three seconds to switch on the stove. For the ignition phase, 15 minutes are available during which the presence of the flame is checked. When the control temperature has been reached, the stove stops the ignition phase and goes into preparaTiON.
front air This menu allows you to set the front air motor speed. range: (comfort, auto). if you select comfort mode, the front air speed is reduced. To ensure combustion efficiency, the front air is excluded when the product is at the minimum power. CONTrOls prOCeDUre ...
Chrono This function allows you to program the stove to switch on and off automatically. The factory setting for cHrono is off. The chrono allows you to program 4 time slots within a day to be used for every day of the week. in each time slot, it is possible to set the ignition and switch-off times, the days of use of the programmed time slot, the desired temperature and the set power.
Page 21
EXAmPLE oF TimEr wiTH oVErLAPPing TimE SLoTS TimE SLoT 02:00 08:00 16:30 23:00 SET PowEr 02:00 08:00 16:30 23:00 SET THErmoSTAT 22° 18° 02:00 08:00 16:30 23:00 start 02:00 Time slot 1 power 3 - seT ThermOsTaT 22°C stop 23:00 start 08:00 Time slot 2 power 1 - seT ThermOsTaT 18°C...
settings • Date-tiMe • language See chapter: SettingS for firSt uSe • Degrees DiSPLAY This menu allows you to adjust the brightness of the display. The possible values go from OFF, 1 to 20. if OFF, the display backlight is at the maximum intensity and goes out after a 60 second delay.
aDDitional therMostat n.b. : the installation Must be perforMeD by an authoriseD teChniCian There is a possibility to thermostat a room adjacent to the room where the stove has been placed; simply connect a thermostat following the procedure described in the following section (it is advisable to place the optional mechanical thermostat at a heigh from the ground equal to 1.50 m).
TO FIND OUT WHERE YOUR NEAREST SERVICE CENTRE IS, CONTACT YOUR DEALER OR GO TO THE WEBSITE: WWW.LANORDICA-EXTRAFLAME.COM Cleaning and maintenanCe always follow the instruCtions in Complete safety! Make sure that the power cord plug is disconnected as the generator may have been programmed to turn on.
Page 25
burn pot and Combustion Chamber: Remove the pellet slide assembly completely, empty out any ash residues in the burn pot below. Remove the burn pot and empty out any ash residues. Vacuum the ash from the combustion chamber and glow plug tube.
Page 26
Cleaning the Combustion Chamber defleCtor Remove the deflector and eliminate the ash that has deposited at the top of the deflector. ENGLISH...
the seals of the pellet hopper, burn pot and the fire door ensure the CorreCt operation of the stove. they must be regularly CheCked by the user and if they are found to be worn or damaged they must be replaCed immediately. these operations must be performed by a Qualified teChniCian.
It is also advisable to disconnect the generator from the electrical power supply and, for greater safety especially in the presence of children, remove the power cord. Routine maintenance must be performed at least once a year. TO FIND OUT WHERE YOUR NEAREST SERVICE CENTRE IS, CONTACT YOUR DEALER OR GO TO THE WEBSITE: WWW.LANORDICA-EXTRAFLAME.COM ENGLISH...
Page 29
routine maintenanCe THE IMAGES ARE FOR ILLUSTRATIVE PURPOSES ONLY. Fumes motor (disassembly and cleaning and fumes pipe and "T"), new silicone in the provided points Seals, pallet hopper, inspections, ash drawer and door (replace and apply silicone where required) Combustion chamber & exchanger (total cleaning) including cleaning the glow plug duct Hopper (empty out completely and clean) and check seal.
Page 30
routine maintenanCe THE IMAGES ARE FOR ILLUSTRATIVE PURPOSES ONLY. Fumes motor (disassembly and cleaning and fumes pipe and "T"), new silicone in the provided points Seals, pallet hopper, inspections, ash drawer and door (replace and apply silicone where required) Combustion chamber & exchanger (total cleaning) including cleaning the glow plug duct Hopper (empty out completely and clean) and check seal.
Displays Display Reason Generator off sTaRT The START phase is in progress pelleT loaDinG Continuous pellet loading is in progress during the ignition phase iGniTion The ignition phase is in progress pRepaRaTion The preparation phase is in progress WoRk The normal work phase is in progress MoDulaTion The generator is operating at the minimum speed final cleaninG...
EXTRAFLAME S.p.A. cannot be held liable for injury or damage which may - either directly or indirectly - be caused to persons, animals and property ensuing from failure to observe all the instructions provided in the relevant instruction manual and the warnings regarding installation, use and maintenance of the product, that can also be downloaded on the website.
AddITIONAL wARNINGs Only use the fuel recommended by the manufacturer. The product must not be used as an incinerator. Do not use the product as a ladder or supporting structure. Do not place laundry on the product to dry it. Any clothes-horse or similar objects must be kept at due distance from the product. Danger of fire or damage to the coating.
Page 36
The manufacturer reserves the right to vary the characteristics and the data reported in this pamphlet at any moment and without notice, in order to improve its products. This manual, therefore, cannot be regarded as a contract towards other parties. 12/06/2020 004280069-000-MAN.UT MARILENA PLUS AD [E134]...
Need help?
Do you have a question about the Marilena Plus AD and is the answer not in the manual?