CENTRIFUGAL SWITCH CHECK
To check the centrifugal switch, the motor must be accessed by either of the following means:
1. Disconnect and pull unit from main gas supply and into an accessible work area.
2. Leave unit in place and remove motor from inside the oven cavity (refer to MOTOR REPLACEMENT section, Page
42).
With the motor accessed, remove motor junction box cover (Fig. 63).
To test the centrifugal switch, the motor must be running (i.e., power switch must be "ON", door switch must be activated
(door closed) and thermostat must be calling for heat) (Fig. 64).
Fig. 63
Fig. 64