GTO 3200XLS Installation Manual

Dual gate operator system
Table of Contents

Advertisement

Quick Links

Installation Manual
ACCESS
ACCESS
SYSTEMS
SYSTEMS
PROFESSIONAL RESIDENTIAL
PROFESSIONAL RESIDENTIAL
3000XLS
3200XLS
3000XLS
3200XLS
NCB
DUAL Gate Operator System
In a DUAL gate system the LPA 3000XLS is the MASTER gate
operator and the LPA 3200XLS is the SECOND gate operator.
PROFESSIONAL INSTALLATION RECOMMENDED!
WARNING!
This equipment is similar to other gate or door equipment and meets or exceeds
Underwriters Laboratory Standard 325 (UL 325). However, gate equipment has
hazards associated with its use and therefore by installing this product the installer
and user accept full responsibility for following and noting the installation and
safety instructions. Failure to follow installation and safety instructions can result
in hazards developing due to improper assembly. You agree to properly install this
product and that if you fail to do so GTO Access Systems, ("GTO") shall in no event
be liable for direct, indirect, incidental, special or consequential damages or loss of
profits whether based in contract tort or any other legal theory during the course
of the warranty or at any time thereafter. The installer and/or user agree to assume
responsibility for all liability and use of this product releasing GTO Access Systems,
from any and all liability. If you are not in agreement with this disclaimer or do not
feel capable of properly following all installation and safety instructions you may
return this product for full replacement value.
READ ALL INSTRUCTIONS CAREFULLY AND COMPLETELY before attempting to
install and use this automatic gate operator. This gate operator produces a high level
of force. Stay clear of the unit while it is operating and exercise caution at all times.
All automatic gate operators are intended for use on vehicular gates only.
This product meets and exceeds the requirements of UL 325, the standard which
regulates gate operator safety, by Underwriters Laboratories Inc.
www.GateOpenerKing.com | (888) 378 - 1042 | Sales@GateOpenerKing.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 3200XLS and is the answer not in the manual?

Questions and answers

Summary of Contents for GTO 3200XLS

  • Page 1 You agree to properly install this product and that if you fail to do so GTO Access Systems, (“GTO”) shall in no event be liable for direct, indirect, incidental, special or consequential damages or loss of profits whether based in contract tort or any other legal theory during the course of the warranty or at any time thereafter.
  • Page 2: Class Rating

    Class Rating The LPA 3000XLS/3200XLS Gate Operators is intended for use with vehicular swing gates in single family residential applications. The operator is system certified to be in compliance with UL 325, current edition, as of publication date. Vehicular Gate Operator Class Categories: Residential Vehicular Gate Operator—Class I: A vehicular gate operator (or system) intended for use in a home of...
  • Page 3: Table Of Contents

    Check Direction of Gate Swing ....................3 Prepare the Gates.......................... 3 Gate Grounding ..........................3 3000XLS Parts List ......................... 4 3200XLS Parts List ......................... 5 Tools Needed ..........................6 Materials You may Need for the Installation: ..............6 Installation Overview ........................7 Install the Master Gate Operator ....................
  • Page 4: Please Read This First

    Thank you for purchasing a Linear PRO Access 3000XLS/3200XLS. When correctly installed and properly used, your LPA 3000XLS/3200XLS operators will give you many years of reliable service. Please read the following information to ensure you have the correct system for your particular needs. This manual will enable you to properly install your 3000XLS/3200XLS Automatic Gate Operators.
  • Page 5: Important Safety Instructions

    Because GTO automatic gate operators are only part of the total gate operating system, it is the responsibility of the installer/consumer to ensure that the total system is safe for its intended use.
  • Page 6: For The Consumer

    IMPORTANT SAFETY INSTRUCTIONS For The Consumer WARNING: To reduce the risk of injury or death: 1. READ AND FOLLOW ALL INSTRUCTIONS. Failure to meet the requirements set forth in the instruction manual could cause severe injury or death, for which the manufacturer cannot be held responsible. 2.
  • Page 7: During Installation

    6. KEEP GATE AND GATE Operator PROPERLY MAINTAINED. Always turn power to operator OFF before performing any maintenance. Regularly grease the gate hinges. Apply silicone spray to a soft, dry cloth and clean the push-pull tube at least once a month. LPA 3000XLS/3200XLS Instruction Manual www.GateOpenerKing.com | (888) 378 - 1042 | Sales@GateOpenerKing.com...
  • Page 8: Required Safety Precautions For Gates

    Install Warning Signs Warning signs alert people of automatic gate operation and are required when installing the GTO Gate Operator. The Warning Signs included must be installed on both sides of each gate. Furthermore, a walk-through gate must be installed for pedestrian traffic.
  • Page 9: Secondary Means Of Protection Against Entrapment

    A wireless contact sensor shall function under the intended end-use conditions. You may want to consider adding photo beams to your installation. GTO Photo Beams [R4222] provide a “non contact” means of entrapment protection.
  • Page 10 Disconnect operator ONLY when the control box power switch is OFF and the gate is NOT moving. MMDDYY GTO Access Systems, LLC - Tallahassee, Florida USA Product identification and manual operation instruction Warning signs (4 enclosed) to be installed on each side of the gate (3–5 feet above the bottom of the gate).
  • Page 11: Technical Specifications

    GTO/ACCESS SYSTEMS 3000XLS/3200XLS AUTOMATIC GATE OPERATOR DRIVE • Low friction screw drive (linear actuator) rated for -5 ºF to +160 ºF (-21 ºC to +71 ºC). Use of GTO battery heater FM316 (Not solar compatible) is recommended in extreme cold temperatures.
  • Page 12: Before You Begin

    [FM123]. Refer to the Solar Panel and Gate Activity chart below. • All low voltage wire used with the GTO Gate Operator must be 16 gauge dual conductor, stranded, direct burial wire [RB509]. Do not run more than 1000 ft. of wire.
  • Page 13: Check Direction Of Gate Swing

    2. Check Direction of Gate Swing The 3000XLS/3200XLS is designed for Pull-To-Open installations. Push-To-Open installations require a Push-To- Open Bracket [R4388]. Please refer to specific Push-To- Open Installation Information on page 26. Your Property Your Property Pull-To-Open Push-To-Open 3. Prepare the Gates...
  • Page 14: 3000Xls Parts List

    3/8" x 2-1/2" Clevis Pin (1) 1/2" Lock Nut (2) 3/8" x 1-3/4" Clevis Pin (1) Hairpin Clip (2) 3/8" x 1/2" Bushing (1) 3/8" x 3/16" Bushing (2) LPA 3000XLS/3200XLS Instruction Manual www.GateOpenerKing.com | (888) 378 - 1042 | Sales@GateOpenerKing.com...
  • Page 15: 3200Xls Parts List

    6. 3200XLS Parts List Second Gate Operator (1) LPA 3200XLS Arm 40’ Power Cable Warning Signs (2) BRACKET BOX - HB301 Closed Position Gate Bracket (1) Stop Plates (1) Post Bracket (1) Post Pivot Bracket (1) HARDWARE BAG - H301P 3/8"...
  • Page 16: Tools Needed

    MASTER gate and gate operator. The 3200XLS gate operator (40 ft. cable) will be installed on the gate on the opposite side of the driveway from the control box and they will be referred to as the SECOND gate and gate operator throughout this manual.
  • Page 17: Install The Master Gate Operator

    • Masonry columns will require masonry anchors/ hardware (not provided). LPA 3000XLS/3200XLS Instruction Manual www.GateOpenerKing.com | (888) 378 - 1042 | Sales@GateOpenerKing.com...
  • Page 18 ” x 3” hex head bolt and washer through post pivot 3/8" Nut Post Pivot Bracket bracket and post bracket and secure with ” washer, lock washer and nut. LPA 3000XLS/3200XLS Instruction Manual www.GateOpenerKing.com | (888) 378 - 1042 | Sales@GateOpenerKing.com...
  • Page 19: Check Clearance

    This clearance will give the operator the most efficient leverage point for opening and closing the gate and, more importantly, provides the least Clamp possible pinch area. LPA 3000XLS/3200XLS Instruction Manual www.GateOpenerKing.com | (888) 378 - 1042 | Sales@GateOpenerKing.com...
  • Page 20: Install Gate Bracket

    Pin Lock [FM345] . Verify that the operator is level, bolts are tight, and adjust the post bracket assembly if Clevis Pin, Bushing, and Hairpin Clip necessary. Fence Post LPA 3000XLS/3200XLS Instruction Manual www.GateOpenerKing.com | (888) 378 - 1042 | Sales@GateOpenerKing.com...
  • Page 21: Install The Second Gate Operator

    Install the Second Gate Operator (3200XLS) The hardware installation for the 3200XLS is the same as the 3000XLS - follow Steps 1 to 10 on pages 8 - 10 to install the 3200XLS on the second gate. Install the Closed Position Stops The 3000XLS/3200XLS Gate Operators firmly hold the gates in the closed position using positive stops.
  • Page 22 NOTE: The optional ground stop post is used to provide a secure point for the SECOND gate to close against. If you will be using the GTO Automatic Gate Lock accessory with your gate operator system, the low profile ground stop is REQUIRED, as example shown in illustration C.
  • Page 23: Mount Battery Box And Control Box

    Connectors for should extend through the KNOCK-OUT in the second battery. back of the CONTROL BOX. Plug the BATTERY HARNESS wires into the wires coming from the CONTROL BOX. LPA 3000XLS/3200XLS Instruction Manual www.GateOpenerKing.com | (888) 378 - 1042 | Sales@GateOpenerKing.com...
  • Page 24: Mounting The Receiver

    (see illustration). The receiver cable: • Cable length is 10 ft. (receivers with longer cables are available as special order items; call the GTO Sales Department). • NEVER splice receiver cable! • Run the receiver cable through PVC conduit to protect it from damage.
  • Page 25: Connect Operator Power Cables

    Strain Relief Lock Nut Power Cable from Master Operator Power Cable from Sealing Nut Second Operator LPA 3000XLS/3200XLS Instruction Manual www.GateOpenerKing.com | (888) 378 - 1042 | Sales@GateOpenerKing.com...
  • Page 26 BLUE, brown wire into BRN, orange wire into ORG, red wire into RED, and the black wire into the BLK terminal. Tighten the set screws against the end of the wires. CYCLE LPA 3000XLS/3200XLS Instruction Manual www.GateOpenerKing.com | (888) 378 - 1042 | Sales@GateOpenerKing.com...
  • Page 27: Connect The Power Input

    (available at local electrical supply stores) must be used. • The only wire acceptable for use with GTO products is 16 gauge stranded, low voltage, direct burial wire [RB509]. This particular gauge enables the transformer to provide an adequate charge through the control board to the battery at distances up to 1000 ft.
  • Page 28 IMPORTANT: This is a class II indoor transformer; if using transformer outdoors be sure to enclose it in a weatherproof case. LPA 3000XLS/3200XLS Instruction Manual www.GateOpenerKing.com | (888) 378 - 1042 | Sales@GateOpenerKing.com...
  • Page 29: Control Board Settings

    OPEN PULL PUSH MAST LIMIT 2ND LIMIT SLV OPEN DLY. SIMULT. Learn Master Learn 2ND MODE1 Limit Button Limit Button MODE2 LEARN 2ND LIMIT Learn 2ND Limit Button LPA 3000XLS/3200XLS Instruction Manual www.GateOpenerKing.com | (888) 378 - 1042 | Sales@GateOpenerKing.com...
  • Page 30 LEARN MAST LIMIT and/or the LEARN 2ND LIMIT button for 5 seconds. This will clear the memory for the closed limit position. Repeat Steps 1-6. LPA 3000XLS/3200XLS Instruction Manual www.GateOpenerKing.com | (888) 378 - 1042 | Sales@GateOpenerKing.com...
  • Page 31: Adjust The Stall Force Setting

    PUSH MAST LIMIT seconds. 2ND OPEN DLY. SIMULT. MODE1 Auto Close Time Adjust the Auto-Close potentiometer by MODE2 Potentiometer using a small flat blade screwdriver. LEARN 2ND LIMIT LPA 3000XLS/3200XLS Instruction Manual www.GateOpenerKing.com | (888) 378 - 1042 | Sales@GateOpenerKing.com...
  • Page 32: Program Your Personal Transmitter Setting

    Program Your Personal Transmitter Setting All GTO transmitters are set to a standard code at the factory and are ready to operate your GTO gate operator. For your safety and security, we strongly recommend that you replace the factory setting with your own personal setting. Follow the...
  • Page 33: Dip Switches

    Open Instructions on page 26). DIP Switch #4: Dual Operation ON– Second opens simultaneously with master. OFF– Second opens after master. (factory preset). Note: Not applicable for single gate operator. LPA 3000XLS/3200XLS Instruction Manual www.GateOpenerKing.com | (888) 378 - 1042 | Sales@GateOpenerKing.com...
  • Page 34: Connecting Accessories

    • Activation of this input while the gate is closing has no effect (gate will continue to close). • Activation of this input while gate is idle will prevent gate from opening. LPA 3000XLS/3200XLS Instruction Manual www.GateOpenerKing.com | (888) 378 - 1042 | Sales@GateOpenerKing.com...
  • Page 35: Wiring Accessories

    • These 2 terminals are normally open “dry-contact” (no voltage) relay ouput. • Relay is closed when gate is in motion; relay is open when gate is not moving. • These 2 terminals maximum rating is 24Vdc, 1 Amp. LPA 3000XLS/3200XLS Instruction Manual www.GateOpenerKing.com | (888) 378 - 1042 | Sales@GateOpenerKing.com...
  • Page 36: Push-To-Open Installation Information

    3/8" Lock Washer 3/8" Nut Push-To-Open Post Pivot Bracket [R4388] Clamp " Install the 3200XLS Operator Now install the SECOND gate Gate in the Open Position operator on the SECOND gate Pinch Area in the same manner. 2" minimum Clamp...
  • Page 37: Setting The Open Position Limit (Push-To-Open Installations)

    Second gates. Gates will close fully. The gate in CLOSED Gate Gate Operator Operator Postion Step 3A or 3B is now Gates in programmed. Control OPEN Postion Control LPA 3000XLS/3200XLS Instruction Manual www.GateOpenerKing.com | (888) 378 - 1042 | Sales@GateOpenerKing.com...
  • Page 38: Column Installation

    The most difficult solution is to cut a notch in the column to accommodate the operator and power cable. This job is NOT for the inexperienced!* *The Troubleshooting Wizard has detailed information on column mounting. LPA 3000XLS/3200XLS Instruction Manual www.GateOpenerKing.com | (888) 378 - 1042 | Sales@GateOpenerKing.com...
  • Page 39: Troubleshooting Guide

    Troubleshooting Guide If your gate operator does not function properly after it is installed, use this guide before calling the GTO Service Department. Generation 3 Audible Feedback SYMPTOM DIAGNOSIS CHECK: 1 short beep upon Circuit Board • Normal Operation power up Powered Up &...
  • Page 40: Voltage Readings

    Two 12V, 7 amp hour Batteries if using solar power Measure voltage at battery terminals with battery disconnected Charging circuit 12.0 to 14.8 Vdc Measure voltage at battery terminals with battery connected LPA 3000XLS/3200XLS Instruction Manual www.GateOpenerKing.com | (888) 378 - 1042 | Sales@GateOpenerKing.com...
  • Page 41: Repair Service

    Repair Service If your LPA 3000XLS/3200XLS Gate Operators are not operating properly, please follow the steps below: 1. First use the procedures found in the Troubleshooting Guide (see page 29). 2. Use the 24/7 Troubleshooting Wizard at http://support.gtoinc.com. 3. If you are unable to solve the problem, call the LPA Service Department at (800) 543-1236. Refer to the serial number (located on the right side of the control box) and date of purchase when calling for assistance.

This manual is also suitable for:

3000xlsPro-sw3200xls

Table of Contents