GTO 2000XL Installation Manual

Single gate operator system

Advertisement

Installation Manual for the
2000XL
SINGLE Gate Operator System
FOR PROFESSIONAL INSTALLATION ONLY!
WARNING!
This equipment is similar to other gate or door equipment and meets or exceeds
Underwriters Laboratory Standard 325 (UL 325). However, gate equipment has
hazards associated with its use and therefore by installing this product the installer
and user accept full responsibility for following and noting the installation and
safety instructions. Failure to follow installation and safety instructions can result
in hazards developing due to improper assembly. You agree to properly install this
product and that if you fail to do so Gates That Open, LLC, ("GTO") shall in no event
be liable for direct, indirect, incidental, special or consequential damages or loss of
profits whether based in contract tort or any other legal theory during the course
of the warranty or at any time thereafter. The installer and/or user agree to assume
responsibility for all liability and use of this product releasing Gates That Open, LLC,
from any and all liability. If you are not in agreement with this disclaimer or do not
feel capable of properly following all installation and safety instructions you may
return this product for full replacement value.
READ ALL INSTRUCTIONS CAREFULLY AND COMPLETELY before attempting to
install and use this automatic gate operator. This gate operator produces a high level
of force. Stay clear of the unit while it is operating and exercise caution at all times.
All automatic gate operators are intended for use on vehicular gates only.
This product meets and exceeds the requirements of UL 325, the standard which
regulates gate operator safety, as established and made effective March 1, 2000, by
Underwriters Laboratories Inc.
®
, LLC
For more information on the GTO/ACCESS SYSTEMS full line of automatic gate
operators and access controls visit our website at www.gtoaccess.com.
©2010 Gates That Open, LLC
Printed in China for Gates That Open, LLC.
R2000 INST 120310

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 2000XL and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for GTO 2000XL

  • Page 1 You agree to properly install this product and that if you fail to do so Gates That Open, LLC, (“GTO”) shall in no event be liable for direct, indirect, incidental, special or consequential damages or loss of profits whether based in contract tort or any other legal theory during the course of the warranty or at any time thereafter.
  • Page 2 Please record the following information product serial number (located on right side of control box), be sure to keep all receipts for proof of purchase. Refer to this information when calling GTO for service or assistance with your automatic gate opener.
  • Page 3: Table Of Contents

    Solar Panel and Gate Activity Chart ..................2 Check Direction of Gate Swing ....................3 Prepare the Gate ........................... 3 2000XL Parts List ........................... 4 Tools Needed ..........................5 Materials You may Need for the Installation: ..............5 Installation Overview ........................6 Install the Operator ..........................
  • Page 4: Please Read This First

    The 2000XL operator also has an adjustable auto-close feature. It can be set to remain open from 3 to 120 seconds before automatically closing. Pressing the transmitter button at any time after the gate fully opens will cause it to close immediately.
  • Page 5: Important Safety Instructions

    Because GTO automatic gate operators are only part of the total gate operating system, it is the responsibility of the installer/consumer to ensure that the total system is safe for its intended use.
  • Page 6 Zone 3 – the path of the gate. Zone 4 – the space between the gate in the open position and any object such as a wall, fence, etc. Zone 5 – pinch points between the operator and gate. GTO 2000XL Instruction Manual © 120310...
  • Page 7 If any of these signs or warning decals become damaged, illegible or missing, replace them immediately. Contact GTO for free replacements. 2. The gate is automatic and could move at any time, posing a serious risk of entrapment. No one should be in contact with an activated gate when it is moving or stationary.
  • Page 8 7. To operate this equipment safely, YOU must know how to disconnect the operator for manual gate operation (page iii). If you have read the instructions and still do not understand how to disconnect the operator, contact the GTO Service Department.
  • Page 9 The 2000XL utilizes Type A, an inherent (i.e., built-in) entrapment sensing system as the primary type of entrapment protection. Also, the 2000XL has provisions for the connection of Type B1 or B2 protection to be used as the secondary type of entrapment protection, if desired.
  • Page 10 2. Do not allow children to operate gate or play in gate area. 3. This gate is for vehicles only. Pedestrians must 1-800-543-GATE (4283) • www.gtoaccess.com use separate entrance. Logo and warning labels (2) installed on each side of operator housing. viii GTO 2000XL Instruction Manual © 120310...
  • Page 11: Technical Specifications

    Technical Specifications GTO/ACCESS SYSTEMS 2000XL AUTOMATIC GATE OPERATOR DRIVE • Low friction screw drive (linear actuator) rated for -5 ºF to +160 ºF (-21 ºC to +71 ºC). Use of heater bands on arm and control box will enhance performance in extreme cold temperatures. • Powered by a 12 V motor with integral case hardened steel gear reducer. Motor speed reduced to 260 rpm. • Maximum opening arc of 110º. Approximate opening time (90º): 18-22 seconds, depending on weight of gate. POWER • The system is powered by a 12 Vdc, 7.0 Ah, sealed, rechargeable acid battery. • Battery charge is maintained by a 120 Vac, 18 Vac output transformer rectified to 14.5 Vdc through the GTO control board. Blade-style control board fuse is rated for 15 A. NOTE: The transformer should not be directly connected to any battery. Do not replace fuses with higher ampere rated fuses;...
  • Page 12: Before You Begin

    25 watts The figures shown are for winter (minimum 30 watts sunlight). Accessories connected to your system will draw additional power from the battery. 10 Watt Solar Panel [FM123] 5 Watt Solar Panel [FM122] GTO 2000XL Instruction Manual © 120310...
  • Page 13: Check Direction Of Gate Swing

    2. Check Direction of Gate Swing The 2000XL kit is designed for PULL-TO-OPEN installations. PUSH-TO-OPEN installations require a Push-To-Open Bracket [347IH]. Please refer to specific Push-To-Open Installation Information on page 22. Your Property Your Property Pull-To-Open Push-To-Open (arm retracts to open) (arm extends to open) 3.
  • Page 14: 2000Xl Parts List

    3/8" Lock Washer (7) 3/8" Nut (7) 3/8" x 2" Bolt (1) 5/16" Washer (1) 5/16" x 1-3/4" Bolt (1) 5/16" Nut (1) 3/8" x 1-1/2" Clevis Pin (2) Hairpin Clip (2) 3/8" x 3/16" Bushing (2) GTO 2000XL Instruction Manual © 120310...
  • Page 15: Tools Needed

    • PVC Conduit. (Page 6) • The diameter of the post should be at least 6” in order to mount the post bracket. (Page 9) • Depending upon the diameter of the post, you may need longer bolts than those provided. Bolts should be at least 1” longer than the diameter of the post. (Page 9) • Metal plate for wooden posts. (Page 9) • A horizontal or vertical cross member or mounting plate may be needed to mount the operator to the gate. (Page 3) • Some types of installations require U-Bolts. (Page 11) • Surge protection for transformer. (Page 16) • Weatherproof cover for transformer if installed outside. (Page 16) • For push-to-open applications you must have PTO Bracket [347IH). (Page 22) GTO 2000XL Instruction Manual © 120310...
  • Page 16: Installation Overview

    If the gate post is larger than 6" the 2" minimum Post Pivot Bracket can be removed and the center hole of the Post Bracket can be the mounting point for the gate opener. Center hole of post bracket GTO 2000XL Instruction Manual © 120310...
  • Page 17 Muffler Clamp for Gate Bracket Thin Walled Tube Gate Gate Bracket 1" x 6" Wood Wood or Metal Gate Reinforcement Bracket Reinforcement Wood or Metal Reinforcement Panel (not supplied) Gate 1" x 6" Wood Reinforcement GTO 2000XL Instruction Manual © 120310...
  • Page 18: Install The Operator

    While holding the opener level, use C-clamps to temporarily secure the post bracket assembly and gate bracket to the post and gate. Post Bracket Assembly Level Operator Gate Bracket Gate In Open Position Fence Post GTO 2000XL Instruction Manual © 120310...
  • Page 19: Check Clearance

    3/8" holes gate. Gate In Open Position Post Bracket Mark cross member through middle of Assembly gate bracket slots and drill 3/8" holes GTO 2000XL Instruction Manual © 120310...
  • Page 20: Install Gate Bracket

    Post Bracket Assembly bolted to gate post Level Operator Gate Bracket bolted to gate cross member Clevis Pin, Bushing and Hairpin Clip Clevis Pin, Bushing, Gate In Open Position Gate Post and Hairpin Clip GTO 2000XL Instruction Manual © 120310...
  • Page 21: Installation Of The Closed Position Stop Plate

    Installation of the Closed Position Stop Plate The 2000XL Gate Operator firmly holds the gate in the closed position using the closed position stop plate. The closed position stop plate helps stabilize the gate leaf in the closed position. To further enhance the stability and security of your gate, install the optional GTO Automatic Gate Lock (see Accessory Catalog).
  • Page 22: Mount The Control Box And Receiver

    If attaching receiver to metal fence, you should mount receiver on a piece of wood attached to the fence (see illustration). The receiver cable: • Cable length is 10 ft. (receivers with longer cables are available as special order items; call the GTO Sales Department). • NEVER splice receiver cable! • Run the receiver cable through PVC conduit to protect it from damage. • DO NOT run cable in conduit containing AC wiring.
  • Page 23: Connect Operator Power Cable

    NEVER splice wires together. Splicing permits corrosion and seriously degrades the wire’s ability to carry an adequate current. Power Cable from Operator Arm CYCLE SAFETY Correct Wrong Wrong EXIT SHADOW CLOSE EDGE OPEN EDGE Wire Terminal Screwed into Exposed strands Block wire insulation. of wire. GTO 2000XL Instruction Manual © 120310...
  • Page 24: Connect The Transformer

    Pull 6” to 8” of wire into the EXIT SHADOW CLOSE EDGE OPEN EDGE control box. Low Voltage Wire from Transformer Power Cable from Operator Arm PVC Pipe GTO 2000XL Instruction Manual © 120310...
  • Page 25: Connect Battery

    AN OUTLET DURING STEP 3 (page 16)! Connect Battery Step 1 Make sure the control box power switch is OFF. Remove the control box cover and slide the battery into position (terminals to the right). ON/OFF Switch GTO 2000XL Instruction Manual © 120310...
  • Page 26: Program Control Board

    (see pg 18). If you have a Push-To-Open Installation, see page 22. Step 1: TURN CONTROL BOX ON. Your 2000XL has two Limit Settings: OPEN Limit setting: (Gate in the OPEN POSITION/arm fully retracted). The OPEN limit can only be adjusted by moving the gate bracket.
  • Page 27: Adjust The Stall Force Setting

    MIN position until the gate operates smoothly without obstructing from its own weight or wind conditions. NOTE: you may need to increase the stall force in cold temperatures due to increased resistance from gate hinges. GTO 2000XL Instruction Manual © 120310...
  • Page 28: Set Auto Close Time

    2ND LIMIT Program Your Personal Transmitter Setting All GTO transmitters are set to a standard code at the factory and are ready to operate your gate operator. For your safety and security, we strongly recommend that you replace the factory setting with your own personal setting.
  • Page 29: Control Board Settings

    Push- To-Open bracket (see Push-To-Open Instructions on page 22). DIP Switch #4: Dual Operation ON– Second opens simultaneously with master. OFF– Second opens after master (factory preset). Note: Not applicable for single gate operator. GTO 2000XL Instruction Manual © 120310...
  • Page 30: Connnecting Accessories

    CLOSE EDGE: (Typically for use with safety edge device) • Activation of this input while the gate is closing will cause the gate to stop and reverse direction for approximately 2 seconds. • Activation of this input while the gate is opening has no effect (gate will continue to open). • Activation of this input while gate is idle will prevent gate from closing. OPEN EDGE: (Typically for use with safety edge device) • Activation of this input while the gate is opening will cause the gate to stop and reverse direction for approximately 2 seconds. • Activation of this input while the gate is closing has no effect (gate will continue to close). • Activation of this input while gate is idle will prevent gate from opening. GTO 2000XL Instruction Manual © 120310...
  • Page 31: Wiring Accessories

    Digital Keypad (F310) NOTE: There may be additional connection options for applications that are not illustrated here. Refer to accessory manuals for details. Connecting Other Auxiliary Devices (Sirens, Lights, etc.) • These 2 terminals are normally open “dry-contact” (no voltage) relay ouput. • Relay is closed when the gate is in motion; Relay is open when the gate is not in motion. • These 2 terminals maximum rating is 24Vdc, 1 Amp. GTO 2000XL Instruction Manual © 120310...
  • Page 32: Push-To-Open Installation Information

    In a Push-To-Open installation the operator is installed while the gate is in the CLOSED POSITION. Install the Operator Gate In Closed Position Follow directions for installing the 2000XL beginning on page 7. The Push-To-Open installation differs from the Pull-To-Open...
  • Page 33: Setting The Open Position Limit (Push-To-Open Installations)

    “LEARN MAST LIMIT” button for 2 seconds. This will clear the memory for the open limit position. Follow steps one (1) to four (4) again. GTO 2000XL Instruction Manual © 120310...
  • Page 34: Column Installation

    Gate Column Column Mount Example (A + B can not exceed 15 inches) Pivot Bracket Example: If A is 6" then B cannot exceed 9" *The Troubleshooting Wizard has detailed information on column mounting. GTO 2000XL Instruction Manual © 120310...
  • Page 35: Troubleshooting Guide

    *measure voltage at battery terminals with battery disconnected Charging circuit ..................12.0 to 14.8 Vdc *measure voltage at battery terminals with battery connected If your gate operator does not function properly after it is installed, use this guide before calling the GTO Service Department. Generation 3 Audible Feedback...
  • Page 36 Terminal Shorted accessory wired to this terminal. • Try the remote. If the remote works, the problem is the accessory. RF (yellow) Flickers Receiving 318 MHz • Normal operation when remote or wireless keypad is used. RF (yellow)OFF No 318 MHz RF • Battery in Remote Received • Program Remote • Antenna Receiver Connections • Antenna Receiver Power (green) AC or Solar Power • Normal Operation Present GTO 2000XL Instruction Manual © 120310...
  • Page 37: Repair Service

    2. Use the 24/7 Troubleshooting Wizard at http://support.gtoinc.com. 3. If you are unable to solve the problem, call the GTO Service Department at (800) 543-1236, or (850) 575- 4144. Refer to the serial number (located on the right side of the control box) and date of purchase when calling for assistance.
  • Page 38: Accessories

    Accessories for 2000XL Please visit www.gtoaccess.com for photos and detailed descriptions of GTO Accessories. Or call 1-800-543-GATE (4283). POWERING ACCESSORIES Low Voltage Wire [RB509] The 16 gauge, multi-stranded, dual conductor low voltage Wire is for connecting the AC powered transformer, solar panel or wired accessories to the system’s control board. This specially designed wire is UV treated, PVC coated, and ready for direct burial.
  • Page 39 LOCKING & SECURITY ACCESSORIES Automatic Gate Lock [FM144/FM142] The #1 Accessory For Swing Gate Operators! Designed for added security in conjunction with GTO Automatic Gate Operators. The gate lock unlocks and locks automatically when the gate opens and closes. The perfect solution for high wind conditions. Bulldog Pedestrian Gate Lock [FM145] Designed to mount on horizontal swing “walk through” wood, chain link, and metal pedestrian gates opening in or out.
  • Page 40 HARDWARE ACCESSORIES Push To Open Brackets [347IH] Required when the 2000XL must push a gate open (arm extends to open), such as away from a sloping driveway or where space prevents gate from opening into the property (pull to open). Order two brackets for a dual swing gate installation.
  • Page 42 ACCESS SYSTEMS PROFESSIONAL RESIDENTIAL 3121 Hartsfield Road • Tallahassee, Florida, USA 32303 (850) 575-0176 • Fax (850) 575-8912 Web site www.gtoaccess.com 24/7 Troubleshooting Wizard: http://support.gtoinc.com...