GTO 3000XLS Installation Manual

GTO 3000XLS Installation Manual

Access systems
Hide thumbs Also See for 3000XLS:

Advertisement

PROFESSIONAL RESIDENTIAL
3000XLS
3000XLS
In a DUAL gate system the 3000XLS is the MASTER gate operator
and the 3200XLS is the SECOND gate operator.
PROFESSIONAL INSTALLATION RECOMMENDED!
This equipment is similar to other gate or door equipment and meets or exceeds
Underwriters Laboratory Standard 325 (UL 325). However, gate equipment has
hazards associated with its use and therefore by installing this product the installer
and user accept full responsibility for following and noting the installation and
safety instructions. Failure to follow installation and safety instructions can result
in hazards developing due to improper assembly. You agree to properly install this
product and that if you fail to do so Gates That Open, LLC, ("GTO") shall in no event
be liable for direct, indirect, incidental, special or consequential damages or loss of
profits whether based in contract tort or any other legal theory during the course
of the warranty or at any time thereafter. The installer and/or user agree to assume
responsibility for all liability and use of this product releasing Gates That Open, LLC,
from any and all liability. If you are not in agreement with this disclaimer or do not
feel capable of properly following all installation and safety instructions you may
return this product for full replacement value.
READ ALL INSTRUCTIONS CAREFULLY AND COMPLETELY before attempting to
install and use this automatic gate operator. This gate operator produces a high level
of force. Stay clear of the unit while it is operating and exercise caution at all times.
All automatic gate operators are intended for use on vehicular gates only.
This product meets and exceeds the requirements of UL 325, the standard which
regulates gate operator safety, as established and made effective March 1, 2000, by
For more information on the GTO/ACCESS SYSTEMS full line of automatic gate
operators and access controls visit our website at www.gtoaccess.com.
©2011 Gates That Open, LLC
Installation Manual
ACCESS
SYSTEMS
DUAL Gate Operator System
WARNING!
Underwriters Laboratories Inc.
Printed in China for Gates That Open, LLC.
ACCESS
SYSTEMS
PROFESSIONAL RESIDENTIAL
3200XLS
3200XLS
R4818 01.10.12

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 3000XLS and is the answer not in the manual?

Questions and answers

HARRY KALE
March 31, 2025

my charging lite is blinking red

3 comments:
HARRY KALE
March 31, 2025

charging light blinking re and gate not workimg

HARRY KALE
March 31, 2025

3200xls gate opener charging lite blinking red and will not operate

Mr. Anderson
March 31, 2025

The charging light blinking red on your GTO 3000XLS may indicate a low or bad battery, blown fuse, or loose battery harness connections. Check for:

- Low or bad battery
- Battery under load
- Loose battery harness connections
- Blown fuse

Address these issues to resolve the blinking red charging light.

This answer is automatically generated

David Irish
April 19, 2025

Do the 3000xls control arms ever need to be serviced such as adding or replacing the grease / lubricant inside?

1 comments:
Mr. Anderson
May 10, 2025

Yes, the GTO 3000XLS control arms require servicing. The gate hinges should be regularly greased, and the push-pull tube should be cleaned with silicone spray applied to a soft, dry cloth at least once a month.

This answer is automatically generated

Subscribe to Our Youtube Channel

Summary of Contents for GTO 3000XLS

  • Page 1 You agree to properly install this product and that if you fail to do so Gates That Open, LLC, (“GTO”) shall in no event be liable for direct, indirect, incidental, special or consequential damages or loss of profits whether based in contract tort or any other legal theory during the course of the warranty or at any time thereafter.
  • Page 2 Class Rating The GTO 3000XLS/3200XLS Gate Operators is intended for use with vehicular swing gates in single family residential applications. The operator is system certified to be in compliance with UL 325, current edition, as of publication date. Vehicular Gate Operator Class Categories: Residential Vehicular Gate Operator—Class I: A vehicular gate operator (or system) intended for use in a home of...
  • Page 3: Table Of Contents

    Solar Panel and Gate Activity Chart ..................2 Check Direction of Gate Swing ....................3 Prepare the Gates.......................... 3 Gate Grounding ..........................3 3000XLS Parts List ......................... 4 3200XLS Parts List ......................... 5 Tools Needed ..........................6 Materials You may Need for the Installation: ..............6 Installation Overview ........................
  • Page 4: Please Read This First

    Thank you for purchasing a GTO/ACCESS SYSTEMS 3000XLS/3200XLS. When correctly installed and properly used, your 3000XLS/3200XLS operators will give you many years of reliable service. Please read the following information to ensure you have the correct system for your particular needs. This manual will enable you to properly install your 3000XLS/3200XLS Automatic Gate Operators.
  • Page 5: Important Safety Instructions

    Because GTO automatic gate operators are only part of the total gate operating system, it is the responsibility of the installer/consumer to ensure that the total system is safe for its intended use.
  • Page 6 Zone 3 – the path of the gate. Zone 4 – the space between the gate in the open position and any object such as a wall, fence, etc. Zone 5 – pinch points between the operator and gate. GTO 3000XLS/3200XLS Instruction Manual © 01.10.12...
  • Page 7 If any of these signs or warning decals become damaged, illegible or missing, replace them immediately. Contact GTO for free replacements. 2. The gate is automatic and could move at any time, posing a serious risk of entrapment. No one should be in contact with an activated gate when it is moving or stationary.
  • Page 8: Required Safety Precautions For Gates

    7. To operate this equipment safely, YOU must know how to disconnect the operator for manual gate operation (page iii). If you have read the instructions and still do not understand how to disconnect the operator, contact the GTO Service Department.
  • Page 9: Secondary Means Of Protection Against Entrapment

    A wireless contact sensor shall function under the intended end-use conditions. You may want to consider adding photo beams to your installation. GTO Photo Beams [R4222] provide a “non contact” means of entrapment protection.
  • Page 10 (3–5 feet above the bottom of the gate). label (1) installed on control box. Logo and warning labels (2) installed on each side of master operator housing. Logo and warning labels (2) installed on each side of second operator housing. viii GTO 3000XLS/3200XLS Instruction Manual © 01.10.12...
  • Page 11: Technical Specifications

    Technical Specifications GTO/ACCESS SYSTEMS 3000XLS/3200XLS AUTOMATIC GATE OPERATOR DRIVE • Low friction screw drive (linear actuator) rated for -5 ºF to +160 ºF (-21 ºC to +71 ºC). Use of GTO battery heater FM316 (Not solar compatible) is recommended in extreme cold temperatures. • Powered by a 12 V motor with integral case hardened steel gear reducer. Motor speed reduced to 375 rpm. • Maximum opening arc of 110º. Approximate opening time (90º): 15-20 seconds, depending on weight of gate. POWER • The system is powered by a 12 Vdc, 7.0 Ah, sealed, rechargeable acid battery. • Battery charge is maintained by a 120 Vac, 18 Vac output transformer. Blade-style control board fuse is rated for 25 A. NOTE: The transformer should not be directly connected to any battery. Do not replace fuses with higher ampere rated fuses;...
  • Page 12: Before You Begin

    NOTE: A minimum of 10 watts solar charging power is needed to charge the batteries. Adding a second battery [RB500] will improve the number of gate cycles. 10 Watt Solar Panel [FM123] 5 Watt Solar Panel [FM122] GTO 3000XLS/3200XLS Instruction Manual © 01.10.12...
  • Page 13: Check Direction Of Gate Swing

    2. Check Direction of Gate Swing The 3000XLS/3200XLS is designed for Pull-To-Open installations. Push-To-Open installations require a Push-To- Open Bracket [R4388]. Please refer to specific Push-To- Open Installation Information on page 25. Your Property Your Property Pull-To-Open Push-To-Open 3. Prepare the Gates...
  • Page 14: 3000Xls Parts List

    1/2" x 2-3/4" Bolt (2) 1/2" Washer (2) 3/8" x 2-1/2" Clevis Pin (1) 1/2" Lock Nut (2) 3/8" x 1-3/4" Clevis Pin (1) Hairpin Clip (2) 3/8" x 1/2" Bushing (1) 3/8" x 3/16" Bushing (2) GTO 3000XLS/3200XLS Instruction Manual © 01.10.12...
  • Page 15: 3200Xls Parts List

    1/2" x 2-3/4" Bolt (2) 1/2" Washer (2) 3/8" x 2-1/2" Clevis Pin (1) 1/2" Lock Nut (2) 3/8" x 1-3/4" Clevis Pin (1) Hairpin Clip (2) 3/8" x 1/2" Bushing (1) 3/8" x 3/16" Bushing (2) GTO 3000XLS/3200XLS Instruction Manual © 01.10.12...
  • Page 16: Tools Needed

    [R4388). IMPORTANT: The 3000XLS gate operator (6 ft. cable) will be installed on the gate on the same side of the driveway as the control box and they will be referred to as the MASTER gate and gate operator. The 3200XLS gate operator (40 ft. cable) will be installed on the gate on the opposite side of the driveway from the control box and they will be referred to as the SECOND gate and gate operator throughout this manual.
  • Page 17: Installation Overview

    • A post smaller than 6” in diameter should be made of metal instead of wood so that it will remain stable while the operator is moving the gate. • Masonry columns will require masonry anchors/ hardware (not provided). GTO 3000XLS/3200XLS Instruction Manual © 01.10.12...
  • Page 18: Install The Post Bracket Assembly

    3/8" Lock Washer Insert ” x 3” hex head bolt and washer through post pivot 3/8" Nut Post Pivot Bracket bracket and post bracket and secure with ” washer, lock washer and nut. GTO 3000XLS/3200XLS Instruction Manual © 01.10.12...
  • Page 19 2“ of clearance between the gate and the operator in both the open and closed positions. This clearance will give the operator the most efficient leverage point for opening and closing the gate and, more importantly, provides the least Clamp possible pinch area. GTO 3000XLS/3200XLS Instruction Manual © 01.10.12...
  • Page 20: Check Clearance

    Pin Lock [FM345] . Verify that the operator is level, bolts are tight, and adjust the post bracket assembly if Clevis Pin, Bushing, and Hairpin Clip necessary. Fence Post GTO 3000XLS/3200XLS Instruction Manual © 01.10.12...
  • Page 21: Install The Second Gate Operator

    Install the Second Gate Operator (3200XLS) The hardware installation for the 3200XLS is the same as the 3000XLS - follow Steps 1 to 10 on pages 8 - 10 to install the 3200XLS on the second gate. Install the Closed Position Stops The 3000XLS/3200XLS Gate Operators firmly hold the gates in the closed position using positive stops.
  • Page 22 NOTE: The optional ground stop post is used to provide a secure point for the SECOND gate to close against. If you will be using the GTO Automatic Gate Lock accessory with your gate operator system, the low profile ground stop is REQUIRED, as example shown in illustration C.
  • Page 23: Mount The Control Box And Receiver

    • DO NOT mount receiver directly to metal fence or metal post (this will decrease signal range). Use a piece of wood between receiver and metal surface. The receiver cable: • Cable length is 10 ft. (receivers with longer cables are available as special order items; call the GTO Sales Department). • NEVER splice receiver cable! • Run the receiver cable through PVC conduit to protect it from damage. • DO NOT run cable in conduit containing AC wiring.
  • Page 24: Connect Operator Power Cables

    CYCLE SAFETY EXIT SHADOW CLOSE EDGE OPEN EDGE Lock Nut Space for optional second 12 Volt battery (see Accessory Catalog) Strain Relief Master Operator Power Cable Sealing Nut Secondary Operator Power Cable GTO 3000XLS/3200XLS Instruction Manual © 01.10.12...
  • Page 25 ORG, red wire into RED, and the black wire 18 VAC LOCK BLUE BLUE COM COM SOLAR 2ND OPERATOR MASTER OPERATOR into the BLK terminal. Tighten the set screws against the end of the wires. GTO 3000XLS/3200XLS Instruction Manual © 01.10.12...
  • Page 26: Connect The Power Input

    Pull 6” to 8” of wire into the control box. Low Voltage Wire from Transformer Power Cable from Master Operator PVC Pipe Power Cable from Secondary Operator GTO 3000XLS/3200XLS Instruction Manual © 01.10.12...
  • Page 27 Make sure the exposed wires do not touch each other! DO NOT PLUG THE TRANSFORMER INTO AN OUTLET DURING THIS STEP! THE TRANSFORMER MUST ONLY BE PLUGGED INTO AN OUTLET DURING STEP 3 (page 18)! GTO 3000XLS/3200XLS Instruction Manual © 01.10.12...
  • Page 28: Connect Battery

    Postion Master Second Gate Gate Operator Operator ON/OFF Switch Step 2 Press the transmitter to activate operator arms. The gates will begin to CLOSE. Gates Control Closing Master Second Gate Gate Operator Operator GTO 3000XLS/3200XLS Instruction Manual © 01.10.12...
  • Page 29: Set The Closed Position Limit (For Pull-To-Open Applications)

    LEARN 2ND LIMIT for 5 MODE1 Limit Button Limit Button MODE2 seconds, or until buzzer beeps to set LEARN closed postion. 2ND LIMIT (Second gate is now programmed) Learn 2ND Limit Button GTO 3000XLS/3200XLS Instruction Manual © 01.10.12...
  • Page 30: Adjust The Stall Force Setting

    OFF, or from 3 to 120 WARNING LEARN OPEN PULL PUSH MAST LIMIT seconds. 2ND OPEN DLY. SIMULT. MODE1 Auto Close Time Adjust the Auto-Close potentiometer by MODE2 Potentiometer using a small flat blade screwdriver. LEARN 2ND LIMIT GTO 3000XLS/3200XLS Instruction Manual © 01.10.12...
  • Page 31: Program Your Personal Transmitter Setting

    Program Your Personal Transmitter Setting All GTO transmitters are set to a standard code at the factory and are ready to operate your GTO gate operator. For your safety and security, we strongly recommend that you replace the factory setting with your own personal setting. Follow the...
  • Page 32: Control Board Settings

    (see Push-to- Open Instructions on page 25). DIP Switch #4: Dual Operation ON– Second opens simultaneously with master. OFF– Second opens after master. (factory preset). Note: Not applicable for single gate operator. GTO 3000XLS/3200XLS Instruction Manual © 01.10.12...
  • Page 33: Connecting Accessories

    6 CLOSE EDGE: (Typically for use with safety edge device) • Activation of this input while the gate is closing will cause the gate to stop and reverse direction for approximately 2 seconds. • Activation of this input while the gate is opening has no effect (gate will continue to open). • Activation of this input while gate is idle will prevent gate from closing. 7 OPEN EDGE: (Typically for use with safety edge device) • Activation of this input while the gate is opening will cause the gate to stop and reverse direction for approximately 2 seconds. • Activation of this input while the gate is closing has no effect (gate will continue to close). • Activation of this input while gate is idle will prevent gate from opening. GTO 3000XLS/3200XLS Instruction Manual © 01.10.12...
  • Page 34: Wiring Accessories

    NOTE: Connections are for typical applications. Digital Keypad There may be additional connection options for applications that are not illustrated here. Connecting Other Auxiliary Devices (Sirens, Lights, etc.) • These 2 terminals are normally open “dry-contact” (no voltage) relay ouput. • Relay is closed when gate is in motion; relay is open when gate is not moving. • These 2 terminals maximum rating is 24Vdc, 1 Amp. GTO 3000XLS/3200XLS Instruction Manual © 01.10.12...
  • Page 35: Push-To-Open Installation Information

    [R4388]. In a Push-To-Open installation the operator is installed while the gate is in the CLOSED POSITION. Install the Operator Follow directions for installing the 3000XLS Gate In Closed Position beginning on page 7. The Push-To-Open installation differs from the Pull-To-Open installation in the following ways: 1.
  • Page 36: Setting The Open Position Limit (Push-To-Open Installations)

    Press the transmitter to CLOSE the Gates in Master Limit Button Second CLOSED gates. Gates will close fully. The gate in Gate Gate Operator Operator Postion Step 3A or 3B is now Gates in programmed. Control OPEN Postion Control GTO 3000XLS/3200XLS Instruction Manual © 01.10.12...
  • Page 37: Column Installation

    Example: If A is 7" then B cannot exceed 9" The most difficult solution is to cut a notch in the column to accommodate the operator and power cable. This job is NOT for the inexperienced!* *The Troubleshooting Wizard has detailed information on column mounting. GTO 3000XLS/3200XLS Instruction Manual © 01.10.12...
  • Page 38: Troubleshooting Guide

    Troubleshooting Guide If your gate operator does not function properly after it is installed, use this guide before calling the GTO Service Department. Generation 3 Audible Feedback SYMPTOM DIAGNOSIS CHECK: 1 short beep upon Circuit Board • Normal Operation power up Powered Up &...
  • Page 39: Voltage Readings

    12.5 to 13.5 Vdc or Two 12V, 7 amp hour Batteries if using solar power Measure voltage at battery terminals with battery disconnected Charging circuit 12.0 to 14.8 Vdc Measure voltage at battery terminals with battery connected GTO 3000XLS/3200XLS Instruction Manual © 01.10.12...
  • Page 40: Repair Service

    2. Use the 24/7 Troubleshooting Wizard at http://support.gtoinc.com. 3. If you are unable to solve the problem, call the GTO Service Department at (800) 543-1236, or (850) 575-4144. Refer to the serial number (located on the right side of the control box) and date of purchase when calling for assistance.
  • Page 41: Accessories

    This specially designed wire is UV treated, PVC coated, and ready for direct burial. Solar Panel Kits [FM122/FM123] If your gate operator is more than 1000 ft. away from an AC power outlet, you can choose to maintain the battery charge with the GTO Solar Panel Kit. • 10 Watt Solar Panel Charging Kit [FM123] • 5 Watt Solar Panel Charging Kit [FM122] Additional/Replacement Battery [RB500] For additional battery power or replacement.
  • Page 42 LOCKING & SECURITY ACCESSORIES Automatic Gate Lock [FM144/FM142] The #1 Accessory For Swing Gate Operators! Designed for added security in conjunction with GTO Automatic Gate Operators. The gate lock unlocks and locks automatically when the gate opens and closes. The perfect solution for high wind conditions. Bulldog Pedestrian Gate Lock [FM145] Designed to mount on horizontal swing “walk through”...
  • Page 43 HARDWARE ACCESSORIES Push To Open Bracket [R4388] Required when the 3000XLS must push a gate open (arm extends to open), such as away from a sloping driveway or where space prevents gate from opening into the property (pull to open). Order two brackets for a dual swing gate installation.
  • Page 44 ACCESS SYSTEMS PROFESSIONAL RESIDENTIAL 3121 Hartsfield Road • Tallahassee, Florida, USA 32303 (850) 575-0176 • Fax (850) 575-8912 Web site www.gtoaccess.com 24/7 Troubleshooting Wizard: http://support.gtoinc.com...

This manual is also suitable for:

32000xlsAccess systems 3000xls

Table of Contents

Save PDF