Supero SUPERSERVER 6025W-NTR+ User Manual page 130

Supermicro superserver 6025w-ntr plus servers: user guide
Table of Contents

Advertisement

S
S
UPER
ERVER 6025W-NTR+ User's Manual
5. When you are finished, press <Done> (as the screen shown below).
Notes:
1. Before adding a new drive to an array, be sure to back up any data stored on
the new drive; otherwise, all data will be lost.
2. If you stop the Build or Clear process on a RAID 1, you can restart it by press-
ing <Ctrl> and <R>.
3. If you've used the Quick Init option to create a RAID1, it may return some
data mis-comparison when you run a consistency check at a later time. This is
normal.
4. The Adaptec Host RAID allows you to use drives of different sizes in a RAID.
However, you can only select a smaller drive as the source or first drive during
a build operation.
5. When migrating from single volume to RAID 0, migrating from a larger drive to
a smaller drive is allowed. However, the destination drive must be at least half the
capacity of the source drive.
6. It is not recommended that you migrate or build an array on Windows dynamic
disks (volumes) because it will result in data loss.
Warning: Do not interrupt the process when you create a RAID 0 using the Migrate
option. If you do, you will not be able to restart the system, or to recover the data
that was on the source drive.