SuperBlade User's Manual
NOTE: See the SuperBlade Network Modules User's Manual on your enclosed
CD-ROM disc for details on all 1Gb Ethernet modules, 1Gb pass-through
modules, 1/10Gb Ethernet modules, 10Gb Ethernet pass-through modules and
InfiniBand modules for the SuperBlade system.
4-1
Chassis Management Module
The Chassis Management Module (CMM)
system. This "command" module communicates with the blade units, the power supplies
and the blade switches. Used in conjunction with the Web Interface or IPMI View
management software, the CMM provides administrator control over individual blade
units, power supplies, cooling fans and networking switches and monitors onboard
temperatures, power status, voltage levels and fan speeds.
The CMM provides a dedicated, local and remote KVM (keyboard/video/mouse)
connection over an out of band TCP/IP Ethernet network during any server state
(functioning, blue-screen, powered down, BIOS and so on). It also supports Virtual
Media (VM) redirection for CD, floppy and USB mass storage devices and configures
such information as the switch IP addresses. A summary of CMM features is shown in
Table
4-3.
8
1
Item#
Description
1
Power LED
2
Activity LED
3
Fault LED
4
Ethernet Port
5
VGA (Monitor) Port
Figure 4-2. Chassis Management Module
2
3
4
Table 4-2. CMM Module Interface
(Figure
4-2) is a required module in a blade
5
6
4-2
9
7