PERCo TTD-12A Assembly And Operation Manual

PERCo TTD-12A Assembly And Operation Manual

Motorized box tripod turnstile with automatic anti-panic folding arms and capability of additional equipment installation

Advertisement

Quick Links

ASSEMBLY AND OPERATION MANUAL
TTD-12A
Motorized box tripod turnstile with automatic
anti-panic folding arms and capability of additional
equipment installation

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TTD-12A and is the answer not in the manual?

Questions and answers

Summary of Contents for PERCo TTD-12A

  • Page 1 ASSEMBLY AND OPERATION MANUAL TTD-12A Motorized box tripod turnstile with automatic anti-panic folding arms and capability of additional equipment installation...
  • Page 2: Table Of Contents

    Design of different types of turnstile side covers ............. 35 Appendix 2. Algorithm of issuing command at pulse control mode ..........38 Appendix 3. Algorithm of issuing command at potential control mode ........39 Appendix 4. Configuring PERCo ACS controller for operation with the card capture reader..40...
  • Page 3: Application

    Assembly and Operation Manual Dear Customer! Thank you for purchasing PERCo product. Please follow instructions given in this Manual carefully and this high-quality product will provide many years of trouble-free use. Assembly and operation manual for the TTD-12A motorized box tripod turnstile with automatic anti-panic arms and capability of additional equipment installation (hereinafter –...
  • Page 4: Technical Specifications

    ................. 1361×750×1024 mm Turnstile net weight ....................... max. 100 kg Figure 1. Overall dimensions of the TTD-12A turnstile As a power supply of the turnstile, the manufacturer recommends using power supplies with an output voltage of 24VDC and a maximum load current of at least 6.5 A, excluding the consumption of additional equipment.
  • Page 5: Delivery Set

    Types of side covers and their application are shown in Table 1. Design and dimensions of different types of covers - see Appendix 1. Table 1. Types and application of serially produced side covers for TTD-12A turnstiles Type Design...
  • Page 6: Additional Equipment Supplied On Request

    "Suprema FaceLite", C-10P.2 cover is used for installation of other FRTs. Be sure to purchase a rack mount bracket that matches the product you are installing. A list of bracket types can be found on the www.perco.com website. Additional equipment supplied on request WRC kit ............................
  • Page 7: Design

    The design of the turnstile is shown in Fig. 2. Numbers correspond to Fig. 2. Figure 2. TTD-12A turnstile design 1 – main housing; 2 – main cover; 3 – main cover indication block; 4 – cover lock; 5 – barrier arm;...
  • Page 8: Main Housing

    TTD-12A Motorized Box Tripod Turnstile The turnstile comprises a turnstile housing (1), a hub with three barrier arms (5), a main cover (2) with an indication block (3) and a lock (4), two side modules with side indication blocks (6 for TTD-12AB, and 6 and 13 for TTD-12AC) (constant indication of passage direction / access denial (7)) and with side covers (8), and a RC-panel (10).
  • Page 9: Rc-Panel

    Assembly and Operation Manual Constant indication block (7) is designed for showing passage direction / denial through the turnstile. It displays the constant indication (white arrow or red cross): – indicator of passage denial in this direction (red cross) – indicator, showing the passage direction (white arrow) Figure 4.
  • Page 10: Interface Board

    TTD-12A Motorized Box Tripod Turnstile Figure 6. Overall view and dimensions of the RC-panel 1, 2, 3 – buttons LEFT, STOP, RIGHT for setting the control commands; 4, 6 – green indicators “Left”, “Right”; 5 – red indicator “Stop” 5.2.5...
  • Page 11 Assembly and Operation Manual X2 (RC) – terminal blocks for connecting the RC-panel, control outputs of the WRC or the ACS • controller (X2.1), as well as the Fire Alarm emergency unblocking device (X2.2); X3 (Light) – terminal blocks for connecting remote indicators ("open" / "closed", X3.1 - for •...
  • Page 12: Control Signals

    TTD-12A Motorized Box Tripod Turnstile № Contact Function X4-X6 (ADD) 1 +12OUT +12V output for optional equipment powering (intrusion detector) DKZP1 Intrusion detector connection DKZP2 Common for DETECT READY signals 6 DETECT Det Out relay output (intrusion detector state) READY Ready relay output (turnstile readiness)
  • Page 13: Control Modes

    Assembly and Operation Manual Figure 8. ACS control elements – normally open relay contact Figure 9. ACS control elements – open collector output layout 5.2.7 Control modes There can be two control modes of the turnstile: pulse and potential. In both modes, turnstile is controlled by sending commands (i.e.
  • Page 14: Turnstile Operation Algorithm

    TTD-12A Motorized Box Tripod Turnstile 5.2.8 Turnstile operation algorithm The turnstile operation algorithm in pulse control mode in case of a single passage in one of the directions: 1. Turnstile initial position - the drive is turned off, passage denial indicator is on, when you try to turn the barrier arms more than 5°...
  • Page 15 Assembly and Operation Manual 1. In standby mode, the receiving slot of the card capture reader is constantly backlighted by the built-in LED indicator. The access card identifier, inserted into the receiving slot, is read by the integrated reader and sent for analysis to the external ACS controller. 2.
  • Page 16: Control Devices Of The Turnstile

    PERCo controllers). • XT6 - connector for power supply of the card capture reader (+24V and GND contacts). XT8 - connector for connecting a built-in card reader (made by PERCo) to the RS-485 • interface lines (“A” and “B” contacts).
  • Page 17: Fire Alarm Emergency Unblocking Device

    Assembly and Operation Manual Figure 11. Standard RC-panel orientation regarding the turnstile post Table 3. Connection of RC-panel cable wires to the XTU2 terminal block for standard and reverse RC-panel orientation RC-panel orientation № Contact Standard Reverse black black white green Unlock A blue...
  • Page 18: Additional Devices Connectable To The Turnstile

    TTD-12A Motorized Box Tripod Turnstile If necessary, the controller inputs can be connected to the READY, DETECT, and COM contacts of the X5 remote terminal block to monitor the corresponding turnstile states. In pulse mode, the turnstile control using the ACS controller is similar to the control from the RC-panel.
  • Page 19: Intrusion Detector And Siren

    Assembly and Operation Manual The output cascades for "PASS A", "PASS B", "Ready", "Detector" are relay contacts (see Fig. 12) with the following signal characteristics: maximum commutation voltage ..................42 V DC maximum commutation current ..................0.25 A closed contact resistance ..................max. 0.15 Ohm The output cascades for "Alarm"...
  • Page 20: Operation Contingencies And Response

    TTD-12A Motorized Box Tripod Turnstile The relay “Light A” (“Light B”) is activated (voltage is supplied to its winding) when the green arrow corresponding to this direction of passage is lit on the LED indication block, and normalized (voltage is not supplied to its winding) when it is not lit. The fact of “Light A” and “Light B” relays operation can be determined by the state of the indicators that are installed near the indicated relays (Fig.
  • Page 21: Safety Requirements

    Assembly and Operation Manual 7 SAFETY REQUIREMENTS Installation safety requirements The turnstile installation must be carried out by specialists who have fully studied this manual and passed safety training, in accordance with the general rules for the implementation of electrical and installation work.
  • Page 22: Installation Tools

    TTD-12A Motorized Box Tripod Turnstile Figure 14. Recommendations for passage zone installation 8.2 Installation tools 1.2÷1.5kW hammer drill • Hard-alloyed drill bit for anchor bolt sleeves • Flat slot screwdriver No.2 • Flat slot screwdriver No.5 (150 mm) • Cross-head screwdriver No.2 •...
  • Page 23: Connection Layout Of The Turnstile And Additional Equipment

    Assembly and Operation Manual Connection layout of the turnstile and additional equipment Figure 15. Internal connection layout of the main housing...
  • Page 24 TTD-12A Motorized Box Tripod Turnstile Figure 16. Connection layout of the turnstile and additional equipment for the TTD-12AB standard version The layout elements are indicated in Table 5. * - Not included in the standard delivery set.
  • Page 25 Assembly and Operation Manual Figure 17. Connection layout of the turnstile and additional equipment for the TTD-12AC version with card capture reader The layout elements are indicated in Table 5. *- Not included in the standard delivery set.
  • Page 26 TTD-12A Motorized Box Tripod Turnstile Table 5. Elements of the connection layout Item Description Main housing Bracket for interface board and additional controller Interface board Control board Rotary group Drive mechanism A6.1 Drive motor A6.2 Position sensor board “Anti-panic” device electric magnet...
  • Page 27: Installation Sequence

    Assembly and Operation Manual Installation sequence Attention! The manufacturer shall not be liable for any damage caused as the result of improper installation and declines any claims arising thereof in case the installation is done not in compliance with the instructions provided in this Manual. Installation order is described with regards to recommendations, given in Sect.
  • Page 28 The installation of the side covers is described in Appendix 1. . Attention! It is possible to install access card readers manufactured by PERCo inside the side modules on special brackets. When third-party readers are installed, they must meet the following specifications: overall reader dimensions .............
  • Page 29 Assembly and Operation Manual Figure 18. TTD-12A turnstile housing installation layout Figure 19. Cable layout inside the housing 1 – CLB; 2 – side module; 3 – side indication block; 4 – remote connector blocks XTU1 and XTU2; 5 – power cable; 6 – cable of the RC-panel;...
  • Page 30 TTD-12A Motorized Box Tripod Turnstile Figure 20. Side indication block (standard side module) 1 – standard side module; 2 – indication block; 3 – bracket; 4 – plate; 5 – nuts with washers for fixing the indication block; 6 – nuts with washers for fixing the bracket, 7 – screws for fixing the plate Figure 21.
  • Page 31: Operation Instructions

    Assembly and Operation Manual 9 OPERATION INSTRUCTIONS Follow the turnstile operation safety requirements (Sect.7.2). It is prohibited! To move through the turnstile passage zone any objects with dimensions exceeding the • width of the passageway. To jerk and hit any elements of the turnstile to prevent their mechanical deformation. •...
  • Page 32: Potential Control Mode

    TTD-12A Motorized Box Tripod Turnstile Indication RC-panel operator Command Turnstile state on the RC- actions on the turnstile panel The turnstile is The green Press both the unlocked for passage indicator of the The green arrow of “Free passage STOP and LEFT in the set direction.
  • Page 33: Algorithm Of The Card Capture Reader Operation

    Assembly and Operation Manual Table 7. Potential control mode (no J1 jumper) Indication Command Operating signal Turnstile state On the RC-panel On the turnstile High level on the The “Red Unlock A and The turnstile is “Both passage The red indicator crosses”...
  • Page 34: Removal And Installation Of The Card Reader Container

    RC-panel / RC-panel WRC receiver / ACS controller If the failure couldn't be fixed, contact the closest PERCo Customer Services. The list of the Customer Services can be found in the certificate of the product. For the TTD-12AC turnstile version.
  • Page 35: Maintenance

    Assembly and Operation Manual 12 MAINTENANCE The turnstile maintenance is required once a year or in case of technical failures. The maintenance should be performed by qualified personnel only. Follow these steps, when performing scheduled maintenance: 1. Switch off the turnstile power supply. The barrier arm will fall down automatically. 2.
  • Page 36: Transportation And Storage

    If any defects in the nodes are detected during the maintenance of the turnstile, as well as after the expiration of the warranty period (see the certificate of the turnstile), it is recommended to contact the PERCo official distributor or PERCo Technical Support Department. 13 TRANSPORTATION AND STORAGE The product in the original package is allowed to be transported only in closed-type cargo transport units (airplanes, railway wagons, containers, closed cars, holds, etc.).
  • Page 37 Assembly and Operation Manual 2. The C-10R side cover is intended for the installation of a built-in RFID reader into the turnstile. It is made of stainless steel and has a window made of radio-transparent material. Figure 24. The C-10R side cover 3.
  • Page 38 TTD-12A Motorized Box Tripod Turnstile Figure 26. The C-10F side cover 5. The C-10RC side cover is intended for the installation into the turnstile in the TTD-12AC version with the built-in card capture reader. It is made of stainless steel with an insert of ABS plastic for the operation of the RFID reader and a receiving slot of the card capture reader.
  • Page 39: Appendix 2. Algorithm Of Issuing Command At Pulse Control Mode

    The side covers are made of stainless steel and have a window made of radio-transparent material and a pole for mounting bracket type BS with the additional equipment. A list of bracket types can be found on the www.perco.com website. Figure 29. The C-10P.1 and C-10P.2 side covers Appendix 2.
  • Page 40: Appendix 3. Algorithm Of Issuing Command At Potential Control Mode

    TTD-12A Motorized Box Tripod Turnstile change. The command is ignored if at the moment of its receipt the state of passage direction B is “Free passage”. “Bi-directional single passage” (open in both directions for ‘one-by-one’ passage). The active front is...
  • Page 41: Appendix 4. Configuring Perco Acs Controller For Operation With The Card Capture Reader

    In the ACS software "PERCo-Web" 1. Log in to PERCo-Web in a browser (see PERCo-Web Admin Guide). 2. Go to the Administration  Configuration section by using the navigation panel. 3. In the page work area, select the main controller that is physically connected to the card capture reader: Edit button on the page toolbar.
  • Page 42 TTD-12A Motorized Box Tripod Turnstile output of the card capture reader) and set the following parameters by using the drop-down menu: • set the Confirmation from EVD value for the Type parameter; • set the Open value for the Normal state of the contact parameter;...
  • Page 43 Assembly and Operation Manual Attention! If the passage permission indication of the card capture reader is controlled directly from the control board of the turnstile, then, it is not necessary to fulfill the requirements of this paragraph. In the window work area, select Additional output No... (the output number must match the output of the controller that is physically connected to the “LED”...
  • Page 44 TTD-12A Motorized Box Tripod Turnstile • for the Verify VISITORS IDs from the еxternal verification device parameter (or from RC-panel): - Upon passage; - Upon passage with TIME VIOLATION; - Upon passage with ZONALITY VIOLATION. • for the Verification confirmation waiting period from EVD (or from RC-panel) parameter –...
  • Page 45 Assembly and Operation Manual in the appeared window, select Additional output No.3 (the output number to which the • “Withdraw card” input of the card capture reader is connected): 18. In the left part of the window work area, select the Withdraw identifiers of visitors after passage checkbox: 19.
  • Page 46 Attention! Using the web interface, you can only configure the simplest algorithm of withdrawing cards from visitors, more advanced settings are possible using the PERCo-Web software. The CT/L04 (CT03) controllers do not support the configuration of operation with the card capture reader via the web interface.
  • Page 47 Assembly and Operation Manual 3. Add the following internal response in the Configuration  Edit  Internal response section: Source type – Visitor ID presentation, − Source number – 1 (the OD number which is physically connected to the card capture −...
  • Page 48 TTD-12A Motorized Box Tripod Turnstile Example of the Internal responses and Physical contacts sections after configuration (template – “Turnstile”, the card capture reader controls the “Direction 1”, “Input 6” and “Output 3” are used to control the card capture reader, “Input 5” is used to receive the “Alarm” signal:...
  • Page 49 (depending on the passage direction controlled by the card capture reader), in this case, the Status of this set of rights should be Unblocked. PERCo Polytechnicheskaya str., 4, block 2 194021, Saint Petersburg Russia Tel: +7 812 247 04 64 E-mail: export@perco.com support@perco.com www.perco.com...
  • Page 50 www.perco.com...

Table of Contents