PERCo Turnichetul TB 1 Assembly & Operation Manual

PERCo Turnichetul TB 1 Assembly & Operation Manual

Electromechanical box tripod turnstile with two built-in readers

Advertisement

Quick Links

Electromechanical
box tripod turnstile
with two built-in
readers
TB 1
-0
Assembly &
Operation Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Turnichetul TB 1 and is the answer not in the manual?

Questions and answers

Summary of Contents for PERCo Turnichetul TB 1

  • Page 1 Electromechanical box tripod turnstile with two built-in readers TB 1 Assembly & Operation Manual...
  • Page 2: Assembly And Operation Manual

    ТВ-01 Electromechanical Box Tripod Turnstile with two built-in readers Assembly and operation manual...
  • Page 3: Table Of Contents

    Assembly and Operation Manual CONTENTS 1. APPLICATION....................... 3 2. OPERATION CONDITIONS..................3 3. TECHNICAL SPECIFICATIONS................... 3 4. STANDARD DELIVERY SET..................4 5. OPTIONAL EQUIPMENT SUPPLIED ON REQUEST ..........4 6. PRODUCT DESCRIPTION ................... 4 6.1. Main features ......................4 6.2. Design ........................5 6.3.
  • Page 4: Application

    TВ-01 Electromechanical box tripod turnstile with two built-in readers Dear Customer, Thank you for purchasing a box tripod turnstile manufactured by PERCo. Please follow in- structions given in this Manual carefully, and this high quality product will provide many years of trouble-free use.
  • Page 5: Standard Delivery Set

    Assembly and Operation Manual RC panel net weight..................max. 0,2 kg Ingress Protection Rating..............IP41 under EN 60529 Electric shock protection class .......III according to GOST R IEC 335-1-94 Mean time to failure ..............min. 1500000 passages Mean lifetime......................8 years Overall dimensions of the TB-01 with barrier arms (L х...
  • Page 6: Design

    TВ-01 Electromechanical box tripod turnstile with two built-in readers  To ensure correct register of passages the resetting mechanism has built-in optic rotation sensors.  A mechanical release lock built into the TB-01 turnstile housing ensures unlocking of the turnstile with a mechanical release key enabling free rotation of barrier arms in a case of emergency.
  • Page 7 Assembly and Operation Manual The TВ-01 turnstile consists of a turnstile housing with built-in electronics and two card readers, three barrier arms and an RC panel (Ref. Fig. 1, items 1-3, 5 and 16). The turnstile housing is fixed to floor with 4 anchor bolts through holes in the turnstile housing base (2).
  • Page 8 TВ-01 Electromechanical box tripod turnstile with two built-in readers Figure 2 – Overall dimensions of the TВ-01 turnstile 6.2.5 The CLB (Ref. Fig. 3) houses:  “X1” (Control) connector to connect the control mechanism (connected to the “X1” connector of the control mechanism with the turnstile cable); ...
  • Page 9: Control Over The Tb-01 Turnstile

    Assembly and Operation Manual Figure 3 – The CLB 6.3. Control over the TB-01 turnstile 6.3.1 The turnstile can be operated from the following control devices:  RC panel;  Wireless remote control;  ACS controller. The above devices can be connected to the turnstile as follows: ...
  • Page 10: Input Control Signals And Their Parameters At Autonomous Control

    TВ-01 Electromechanical box tripod turnstile with two built-in readers 6.3.7 Pin assignment of the CLB connector blocks are given in Figure 3 and on a label located on the inner surface of the turnstile top cover. 6.4. Input control signals and their parameters at autonomous control 6.4.1 The CLB microcontroller processes incoming commands (i.e.
  • Page 11 Assembly and Operation Manual а) Figure 4 – Control elements of an external device: a – a normally open relay contact; b – a circuit with open-collector output. 6.4.3 The relays “PASS A” (contacts “PASS A” and “Common”), “PASS B” (contacts “PASS B”...
  • Page 12: Control Modes

    TВ-01 Electromechanical box tripod turnstile with two built-in readers Detector and Alarm relays is indicated by lighting/going out of red indi- cators located near the corresponding relays (Fig. 3). The output cas- cades for “PASS A”, “PASS B”, “Ready”, “Det Out” and “Alarm” are the relay contacts with the following signal characteristics (Ref.
  • Page 13: Operation From The Rc Panel

    Assembly and Operation Manual 6.5.4 The pulse control mode is intended for the turnstile operation from the RC panel, wireless remote control or an ACS controller, outputs of which support pulse control mode Standard control inputs: “Unlock A”, “Unlock B” and “Stop”. Special control input: “Fire Alarm”.
  • Page 14: Operation From Wireless Remote Control

    TВ-01 Electromechanical box tripod turnstile with two built-in readers and counts the time passed since the moment the RC button corre- sponding to the permitted passage direction А (В) is ressed. 6.5.2.4 At the barrier arms turning 67° the microcontroller forms signal “PASS А...
  • Page 15: Unblocking With A Mechanical Release Key

    Assembly and Operation Manual If while the turnstile is in a locked state (in the “Always locked” mode or in the “Both directions locked” mode, Tables 3 and 4) a signal from the intrusion detector comes, the “Alarm” signal is generated, which is disabled either after 5 sec. or after execution of any received command.
  • Page 16: Marking And Packaging

    TВ-01 Electromechanical box tripod turnstile with two built-in readers A special signal “Ready” is generated in each of the above cases. 6.11.2 In case of unauthorized access the “Ready” signal is formed as follows: at 8° arm rotation one of the optic sensors (Fig. 10) responds and the output contacts “Ready”...
  • Page 17: Operation Safety Requirements

    Assembly and Operation Manual ful not to drop the turnstile housing. 8.1.5 Before first power-up of the TB-01 turnstile make sure installation and all connections are done properly. 8.1.6 Installation of a power supply unit must be performed with observance of safety requirements mentioned in its certificate.
  • Page 18: Installation Tools

    TВ-01 Electromechanical box tripod turnstile with two built-in readers Figure 6 – Installation recommendations 9.2. Installation tools – hammer drill 1,21,5 kW; – hard-alloyed drill bit 16 mm for anchor bolt sleeves; – floor chaser for cable raceways; – flat slot screwdriver №2; –...
  • Page 19 Assembly and Operation Manual electric raceways are laid. Cable routing inside the turnstile housing is shown in Figure 8. Figure 7 – TB-01 turnstile housing installation layout 9.4.3 Insert anchor bolts sleeves into the holes so that they did not stick out above the floor surface.
  • Page 20 TВ-01 Electromechanical box tripod turnstile with two built-in readers Figure 8 – Cable routing inside the TВ-01 turnstile housing: 1 – power cable; 2 – cable from the RC panel/ wireless remote control device; 3 – rotation mechanism connection cable; 4 – cables of card readers №1 and №2; 5 –CLB; 6 – rotation mechanism; 7 - bracket (ACS installation) №1 –...
  • Page 21: Connecting Readers To An Acs

    Assembly and Operation Manual 9.5. Connecting readers to an ACS The readers are connected to an ACS controller with a shielded cable in accordance with Figure A.1 Appendix A. The readers’ lines are connected to the connector blocks Х1.2 (Ref. Fig. А.1 Appendix А).
  • Page 22: Operation Instructions

    TВ-01 Electromechanical box tripod turnstile with two built-in readers Table 2. Change of outcoming data format of the readers: Connection point (conductor) Format of outcoming data of a Wire determining a for- at an output of a regular reader determined by per- mat of outcoming data connection cable of a reader formed connections...
  • Page 23: Turnstile Operating Modes In Pulse Control Mode

    Assembly and Operation Manual 10.3. Turnstile operating modes in pulse control mode See Table 3 for the operating modes set from the RC panel and for the corresponding indication. Please note the following: Setting the operating modes for each direction is independent, i.e. setting the operating mode for one direction does not change the operating mode set earlier for the opposite one;...
  • Page 24: Operation Of The Tb-01 Turnstile In Potential Control Mode

    TВ-01 Electromechanical box tripod turnstile with two built-in readers Free passage Press the STOP The green Turnstile remains in the set direction button indicator “Green arrow” open in the set (open and the button above showing direction for free passage in corresponding the button the passage...
  • Page 25: Operation Of The Turnstile When Controlled By An Acs

    Assembly and Operation Manual Table 4 Potential control mode (the jumper is taken off the J1 connector) LEVELS LED INDICATION INDICATION TURNSTILE TURNSTILE ON THE ON THE № ON THE RC RESPONSE AFTER OPERATING CONTACTS TO TURNSTILE PANEL BARRIER ARMS TURN MODES BE PROVIDED HOUSING...
  • Page 26: In Case Of An Emergency

    TВ-01 Electromechanical box tripod turnstile with two built-in readers 10.6. In case of an emergency 10.6.1 Unlocking with a mechanical release key This function allows for fast unlocking with a mechanical release key, ensuring free rota- tion of barrier arms in both directions. Please refer to Clause 6.10 for how to proceed to unlock the turnstile with a mechanical release key.
  • Page 27: Transportation And Storage

    Assembly and Operation Manual TRANSPORTATION AND STORAGE 11.1 The turnstile in the original package should be transported in closed freight containers or other closed type cargo transport units. 11.2 During storage and transportation the boxes with the turnstiles can be stacked maximum 2 layers high.
  • Page 28 After maintenance works are complete the turnstile is ready for further operation. Figure 10 – Interior components of the TВ-01 turnstile mechanism In case of any defects revealed during visual check please apply to the PERCo Technical Support Department (the PERCo TSD).
  • Page 29 Assembly and Operation Manual APPENDIX А CONNECTION LAYOUT OF THE TB-01 TURNSTILE AND OPTIONAL EQUIPMENT TB-01 turnstile +12VDC intrusion detector +12V Detector +12V Control Detector XT1.L Fire Alarm black common white left button blue stop button Unlock A green right button Stop yellow left indicator...
  • Page 30 TВ-01 Electromechanical box tripod turnstile with two built-in readers Table А.1 Elements of the connection layout Legend Name Q-ty Note Bracket with CLB and connector blocks А2* Intrusion detector CLIP-4 Emergency unblocking device Remote control panel Siren Access control system Wireless remote control MSRF-4 А8*...
  • Page 31 Assembly and Operation Manual TB-01 turnstile orange Controller X1.2 green R0: D0 white R0: D1 blue Led Red R0: Led Red yellow Led Green R0: Led Green brown Beeper R0: Beeper "2" +12V GND & Shield black+shield GND & Shield GND &...
  • Page 32 TВ-01 Electromechanical box tripod turnstile with two built-in readers Table А.2 Elements of the internal connections layout Legend Name Q-ty Note Control mechanism TTR-06.140.00 А2 Bracket with CLB and connector blocks Cover TBC01.150.00 (with a reader) №1 Cover TBC01.150.00 (with a reader) №2 X1.1 Connector block...
  • Page 33 Assembly and Operation Manual APPENDIX B CONTROL SIGNAL ALGORITHM IN PULSE CONTROL MODE The command is a signal active front (signal transfer from the high level to the low level) at any of the contacts at presence of the corresponding signal levels at the other contacts. The following commands can be formed by sending a low-level signal to the contacts “Un- lock A”, “Stop”...
  • Page 34 TВ-01 Electromechanical box tripod turnstile with two built-in readers Active front is at the contact “Unlock B” while there is a low level at the contact “Stop” and a high level at the contact “Unlock A”, or active front is at the contact “Stop” while there is a low level at the contact “Unlock B”...
  • Page 35 Assembly and Operation Manual APPENDIX C CONTROL SIGNAL ALGORITHM IN POTENTIAL CONTROL MODE Both directions are locked (locked for entry and exit) There is a high level at the contacts “Unlock A” and “Unlock B”, or a low level at the contact “Stop”.
  • Page 36 PERCo Industrial Tel.: +7 812 3216172, +7 812 3298924 Fax: +7 812 2923608 Legal address: 123-V ul. Leona Pozemskogo, Pskov, 180600, Russia e-mail: support@perco.ru www.percoweb.com...
  • Page 37 www.percoweb.com...