CONTENTS APPLICATION ........................2 OPERATING CONDITIONS ....................2 TECHNICAL SPECIFICATIONS .................... 3 DELIVERY SET ........................4 Standard delivery set ....................... 4 Additional equipment to be supplied upon request ............4 DESIGN AND OPERATION ....................4 Main features ........................4 Design ..........................5 5.2.1 Turnstile housing .....................
You have purchased a high-quality product, which will serve you for many years to come, if you carefully follow installation and operation rules. The Assembly and Operation Manual (hereinafter referred to as the Manual) for the TTD-08A Electromechanical box tripod turnstile with automatic anti-panic barrier arms contains the instructions on safe transportation, storage, installation, operation, and maintenance of the said product.
............ 1166×750×1016 mm Net weight of the turnstile ....................max. 70 kg Figure 1. Overall dimensions of the TTD-08A turnstile For the turnstile, the manufacturer recommends using power supply units with an output voltage of 12 V DC and a maximum load current of at least 7 A.
Assembly & Operation Manual DELIVERY SET Standard delivery set Basic equipment: Turnstile housing with an installed flywheel and barrier arms ............1 SW2.5 Allen key to a housing top cover ..................1 RC panel with a cable ........................1 Assembly and installation tools: Self-adhesive cable tie mount ....................
RC panel (12). The barrier arms are hinged to the flywheel. The turnstile housing is fixed to the floor with 4 anchor bolts through holes in the turnstile housing base (2). Figure 2. Design of the TTD-08A turnstile Standard delivery set: 1 –...
Assembly & Operation Manual located. The side panels of the turnstile feature additional passage direction indicators, under which passage indication boards are placed. If the side panels, assembled with top covers, are removed, access is gained to four holes in the housing base (2) in order to fix the turnstile to the mounting surface.
TTD-08A Electromechanical box tripod turnstile There are three control buttons for sending commands on the RC front panel. The middle STOP button sends the Passage denial command. The LEFT and RIGHT buttons are used to send a command to unlock the turnstile for passage in the selected direction. LED indicators of the status of the turnstile’s rotary mechanism are located above the buttons.
Page 9
Assembly & Operation Manual Table 1. Contact functions of terminal blocks No. Contact Function of the contact XT1L (In) +12V Connection of +12 V power supply for the intrusion detector Detector Input for connection of the intrusion detector Common 4 Fire Alarm Control input for emergency unblocking of the passage Common Unlock A Control input –...
TTD-08A Electromechanical box tripod turnstile For convenience, the connection contacts of the turnstile’s power supply unit and control devices are placed on the bracket on the XS1 terminal block. The connection is carried out in accordance with the connection layout of the turnstile and additional equipment (see Fig. 12). The turnstile is energized via a power cable (13).
Assembly & Operation Manual 5.2.6 Control modes of the turnstile Two control modes of the turnstile are available: pulse and potential. In both modes, the turnstile is controlled by sending commands (i.e., combination of control signals) to standard control inputs: Unlock A, Stop, and Unlock B as well as to a special Fire Alarm control input.
TTD-08A Electromechanical box tripod turnstile 3. The control mechanism unlocks the rotary mechanism for rotation in the selected direction. Passage in this direction becomes possible. 4. When a user passes through the turnstile, the microcontroller tracks the rotation angle of the barrier arms with optical sensors of the control mechanism.
Assembly & Operation Manual Table 2. Connection of RC-panel cable wires to the XS1 terminal block for standard and reverse RC panel orientation RC panel orientation Contact Standard Reverse black black white green Unlock A blue blue Stop green white Unlock B yellow Led A...
TTD-08A Electromechanical box tripod turnstile The relays have normally open contacts. At the same time, the Common contact for these relays is not connected to the negative terminal of the turnstile’s power supply unit (it is galvanically isolated). In the initial (normalized) condition, when the power supply unit is switched on, the PASS A, PASS B, READY, and DETECTOR relay contacts are closed (voltage is applied to the relay coil), and the ALARM relay contacts are open (voltage is not applied to the relay coil).
Assembly & Operation Manual Voltage supply to the relay coil is indicated by lighting up of the red LED, installed on the control board near the corresponding relay. The output stages for the Light A and Light B relays are changeover relay contacts (Fig. 10) with the following signal characteristics: maximum commutation voltage ................
TTD-08A Electromechanical box tripod turnstile Installation of the top cover back into its working position is carried out in reverse order. After its installation, use the key to return the set screw into its initial position and fix the top cover. Turn on the power supply unit and move the upper barrier arm into the working position to continue the turnstile’s operation.
Assembly & Operation Manual • level the mounting surface so that the fixing points of the turnstile housing lie in the same horizontal plane (check it with a level); • apply embedded reinforcing elements (min. 400×400×300 mm) in case the turnstile has to be installed on a less steady foundation.
TTD-08A Electromechanical box tripod turnstile Cable lengths Cables used for installation are listed in Table 3. Table 3. Cables used during the installation Maximum Minimum Equipment to be cable Cable type cross- Example of the cable connected length, m section, mm AWG 15;...
Assembly & Operation Manual Figure 12. Connection layout of the TTD-08A turnstile and additional equipment Installation procedure Attention! The manufacturer shall not be liable for any damage caused by improper installation and declines any claims arising thereof in case if the installation is not carried out in compliance with the instructions provided in this Manual.
Page 20
3. Drill holes for anchor sleeves in the floor to fix the turnstile housing in accordance with Fig. 13. Figure 13. Marking layout for the TTD-08A turnstile housing installation 4. If it is necessary to lay cables under the floor surface, prepare a cable duct in the floor so that it leads to the area where these cables enter the turnstile housing.
Page 21
The turnstile design enables installation of IR13, IR19 and IR19 OEM readers made by PERCo as well as readers made by third-party manufacturers. Access card readers are not included in the standard delivery set! Readers are to be selected, purchased, and installed in the product by the customer (installer) on their own.
TTD-08A Electromechanical box tripod turnstile Figure 15. Layout of fixing screws 1, 2 - screws for fastening side panels with covers, 3 - screws for fastening the bracket with the control board and remote terminal block 15. Install side panels (6, 7), assembled with top covers (8, 9), back in place in reverse order to their removal.
Assembly & Operation Manual Power-up Follow these steps to power up the turnstile: 1. Check the accuracy of all the connections. 2. Connect the power supply unit to the mains with the voltage and frequency specified in its certificate. 3. Switch on the power supply unit. Red passage denial indicators will light up on the indication blocks, and the red indicator above the STOP button will light up on the RC panel.
TTD-08A Electromechanical box tripod turnstile Actions Indication Command to do via the RC Turnstile status on the RC panel on the turnstile panel The turnstile remains Set the Free Green indicators open in one of the are on for both...
RC panel to the XS1 terminal block In case of other faults and defects, please contact the PERCo Technical Support Department (the PERCo TSD). MAINTENANCE The turnstile maintenance is required once a year and in case of any technical failures; the turnstile must be serviced immediately after repair works.
Page 26
TTD-08A Electromechanical box tripod turnstile 6. Inspect the rotary group of the barrier arms: its resetting mechanism (a pusher, springs, and a roller), optical rotation sensors for the barrier arms, and damper (see Fig. 16). 7. Remove possible contamination from a rotation sensor disk, located in the gap of the optical rotation sensors for the barrier arms, with an alcohol-gasoline blend applied with a clean cloth.
17. Check operation of the turnstile in accordance with Section 9 of this Manual. After technical maintenance works and inspections are complete, the turnstile is ready for further operation. In case of any defects revealed during technical maintenance, please contact the PERCo Technical Support Department (the PERCo TSD). TRANSPORTATION AND STORAGE The turnstile in the manufacturer’s packaging is allowed to be transported only in closed transport...
TTD-08A Electromechanical box tripod turnstile the Passage denial command is received. The command is ignored for the passage direction that is in the Free passage state at the time of its receipt. Free passage in direction A (open for free passage in the A direction)