PERCo TTR-11A Assembly & Operation Manual

PERCo TTR-11A Assembly & Operation Manual

Motorized tripod turnstile with automatic anti-panic arms

Advertisement

Quick Links

ASSEMBLY & OPERATION MANUAL
TTR-11А
Motorized tripod turnstile
with automatic anti-panic arms

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TTR-11A and is the answer not in the manual?

Questions and answers

Summary of Contents for PERCo TTR-11A

  • Page 1 ASSEMBLY & OPERATION MANUAL TTR-11А Motorized tripod turnstile with automatic anti-panic arms...
  • Page 2 TTR-11A Motorized tripod turnstile with automatic anti-panic arms Assembly and Operation Manual...
  • Page 3: Table Of Contents

    CONTENTS APPLICATION ........................3 OPERATING CONDITIONS ....................3 TECHNICAL SPECIFICATIONS .................... 3 DELIVERY SET ........................4 Standard delivery set ....................4 Optional equipment supplied on request ..............5 DESCRIPTION ........................5 Main features ....................... 5 Design ......................... 5 5.2.1 Turnstile housing and base .................. 5 5.2.2 LED indication block ....................
  • Page 4: Application

    TTR-11A Motorized tripod turnstile Dear Customer, Thank you for purchasing the PERCo turnstile. Please follow the instructions given in the Manual carefully, and this quality product will provide many years of trouble-free use. Assembly and operation manual for the TTR-11A motorized tripod turnstile with automatic anti-panic arms (hereinafter - the Manual) contains data necessary for the utter use of the turnstile operating advantages.
  • Page 5: Delivery Set

    Assembly & Operation Manual Vibration resistance rating ..............M28 and M29 (IEC 721-3-5) Mean time to failure .................. min 3,000,000 passages Mean lifetime ........................8 years Turnstile overall dimensions with barrier arm raised (see Fig. 1) ......800×760×1055 mm Turnstile net weight: ......................max 75 kg Figure 1.
  • Page 6: Optional Equipment Supplied On Request

    You can get acquainted with the possible options for brackets for additional. equipment on the website https://www.perco.ru/ or in the technical support of the PERCo company. The WRC kit consists of a receiver connected to the control board and transmitters.
  • Page 7 Assembly & Operation Manual Figure 2. Turnstile overview 1 – turnstile housing; 2 – LED indication block; 3 – barrier arm; 4 – hub; 5 – hub mounting screws; 6 – turnstile base; 7 – housing mounting screws; 8 – front panel; 9 – front panel screws Figure 3.
  • Page 8: Led Indication Block

    TTR-11A Motorized tripod turnstile 5.2.2 LED indication block The housing (1) features LED indication block (2) to inform about the turnstile current status and the established operating mode (Fig. 2 and 4). The display has three pictographic indicators: passage granting indicator...
  • Page 9 Assembly & Operation Manual Control board elements: X1 (+24 GND) – turnstile power supply terminal block; • X2 (POWER+CAN) – connector to connect communication cable with interface board; • X3 (Rotor Sensor) – the rotor position sensor board terminal block (part of the drive (14)); •...
  • Page 10 TTR-11A Motorized tripod turnstile Interface board elements: X1 (ACS) – optional equipment power supply terminal blocks (X1.1), siren connection (X1.2) • and ACS controller inputs for PASS signals (X1.3); • X2 (RC) – terminal blocks for connecting the RC-panel, WRC or ACS controller (X2.1), as well as Fire Alarm emergency unlocking device (X2.2);...
  • Page 11: Control Signals

    Assembly & Operation Manual № Item Designation X3 (LIGHT) Normally open contact of the external Light A output Common contact of the external Light A output Normally closed contact of the external Light A output Normally open contact of the external Light B output Common contact of the external Light B output Normally closed contact of the external Light B output Remote terminal blocks X4-X6 (ADD)
  • Page 12: Turnstile Control Modes

    TTR-11A Motorized tripod turnstile Turnstile emergency unlocking is performed by a low-level signal release from FA connector of the X2 terminal block on the interface board regarding the GND contract. A normally closed relay contact or a ciruit with an open collector output can serve as a control element. In this case all other incoming control commands are ignored.
  • Page 13: Control Devices

    Assembly & Operation Manual 1. Turnstile starting position - the drive is turned off, passage denial indicator is on, when you try to turn the barrier arms more than 5° in any direction, the blocking device locks the hub, an alarm is turned on - passage through the turnstile is closed.
  • Page 14: Fire Alarm Emergency Unlocking Device

    TTR-11A Motorized tripod turnstile If the operator is located on the opposite side regarding the turnstile post, it will be more convenient to shift the RC-panel wires, which are connected to L and R contacts, as well as Led A and Led B (Table 2).
  • Page 15: Additional Devices Connectable To The Turnstile

    Assembly & Operation Manual If necessary, the controller inputs can be connected to the READY, DETECT and COM X5 terminal block contacts to monitor the corresponding turnstile conditions. In the pulse control mode control over the turnstile with an ACS controller is similar to that with the RC-panel.
  • Page 16: Intrusion Detector And Siren

    TTR-11A Motorized tripod turnstile Pass elements for “PASS A”, “PASS B”, “Ready”, “Detector” - relay contacts (Fig. 11) with the following signal characteristics: maximum commutation DC voltage ..................42V maximum commutation current ..................0.25A closed contact resistance ..................max 0.15 Ohm Pass elements for «Alarm»...
  • Page 17: Operation Contingencies And Response

    Assembly & Operation Manual the LED indication unit, and normalized (voltage is not supplied to its winding) when it is not lit. The fact of “Light A” and “Light B” relays operation can be determined by the state of the indicators that are installed near the indicated relays (Fig.
  • Page 18: Safety Requirements

    TTR-11A Motorized tripod turnstile 7 SAFETY REQUIREMENTS 7.1 Installation safety requirements The turnstile installation must be carried out by specialists who have fully studied this manual and passed safety training, in accordance with the general rules for the implementation of electrical and installation work.
  • Page 19: Installation Tools

    Assembly & Operation Manual passage area in such a way that the barrier arms should turn in the passage direction by an angle of more than 60° (Fig. 13). Follow the recommendations (Fig. 13) to ensure the required angle of rotation when installing the turnstile.
  • Page 20 TTR-11A Motorized tripod turnstile lengths are indicated in Sect. 8.3. The installation surface and passage area recommendations are given in Sect. 8.1. Follow this sequence of actions, when installing the turnstile: 1. Unpack the turnstile and check the completeness as per Sect. 4.
  • Page 21 Assembly & Operation Manual Note: RFID-readers admissible dimensions: 150×70×28 mm. Figure 15. Built-in RFID-readers installation 14. Install and connect optional equipment if necessary: ACS controller, intrusion detector and siren; Fire Alarm emergency unlocking device, remote indicators, etc. (Fig. 1). 15. Check serviceability and accuracy of all the electrical connections in accordance with the diagram in Fig.
  • Page 22: Wiring Diagram

    TTR-11A Motorized tripod turnstile 8.5 Wiring diagram Figure 16. Wiring diagram...
  • Page 23: Operation Instructions

    Assembly & Operation Manual Table 4. Wiring diagram description Item Description Q-ty Control board Interface board Drive assembled A3.1 Position sensor board A3.2 Electric drive motor Blocking device optical sensors board LED indication unit “Anti-panic” device electric magnet Blocking device electric magnet Turnstile power supply (battery) 24V Siren DC 12V ACS controller...
  • Page 24: Operating Modes Of The Turnstile At Pulse Control Mode

    TTR-11A Motorized tripod turnstile activation will turn a continuous sound signal on. The sound will stop in 5 sec. To eliminate the sound signal, press any button on the RC-panel. The turnstile is ready for operation. 9.2 Operating modes of the turnstile at pulse control mode After switch on the power supply the turnstile is automatically switched to “Always locked”...
  • Page 25: Operating Modes Of The Turnstile At Potential Control Mode

    Assembly & Operation Manual Indication on Operating Actions to do on Turnstile status modes RC-panel RC-panel LED display Set the “Free The turnstile is “Free passage passage in the set Green arrows for both unlocked for free Both green in the set direction”...
  • Page 26: Troubleshooting

    If the problem remains, we recommend contacting your nearest PERCo service center. The list of PERCo service centers is given in the product certificate. 10 MAINTENANCE The turnstile maintenance is required once a year or in case of technical failures. The maintenance should be performed by qualified personnel only.
  • Page 27: Transportation And Storage

    12. Check the reliability of electromechanical barrier arm unlocking device by turnstile power on/off. In case of any defects revealed during visual check please contact your nearest PERCo service center. The list of PERCo service centers is given in the product certificate.
  • Page 28: Appendix 2. Control Signal Algorithm At Potential Control Mode

    TTR-11A Motorized tripod turnstile “Always locked” (locked for entry and exit) - Active front is at the contact ST while there is a high level at the contacts L, ST and R. Both passage directions are locked at this command.
  • Page 29 PERCo Polytechnicheskaya str., 4, block 2 194021, Saint Petersburg Russia Tel: +7 812 247 04 64 E-mail: export@perco.com support@perco.com www.perco.com...
  • Page 30 www.perco.com...