Download Print this page

Advertisement

Quick Links

OBJECT SCAN
User Manual
RUG-410-EN
Rev. 4.0

Advertisement

loading
Need help?

Need help?

Do you have a question about the RAYSCAN OBJECT SCAN and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ray RAYSCAN OBJECT SCAN

  • Page 1 OBJECT SCAN User Manual RUG-410-EN Rev. 4.0...
  • Page 2 Caution (US only): This product must only be sold to dentists or oral health professionals as stated by the federal law. Copyright Ray Co., Ltd. Publication number: RUG-410-EN Rev. 4.0 (Revised Dec. 18, 2018) This manual is subject to change without prior notice.
  • Page 3 Precautions before using the Model and Bite scan ............10 Installing the Software ..................12 Installing the RAYDENT Connect and Converter ............12 How to use RAYSCAN Object Scan..............14 Object Positioning ......................14 4.1.1 Impression (Maxilla, Mandible) Positioning............14 4.1.2...
  • Page 4 OBJECT SCAN Contents STL Converting ......................38 STL Editing ........................39 Changing configuration ....................40 5.8.1 Language Setting ....................40 5.8.2 Setting Server IP ....................41 5.8.3 Setting Patient Name Format ................42 5.8.4 Setting the Viewer path ..................42 The operation of RAYDENT Converter ............
  • Page 5 OBJECT SCAN 1 Introduction Introduction Purpose To convert CT slice image of object acquired in Object Scan protocol of RAYSCAN system to 3D mesh data and use it for prosthesis and implant design. Features ▪ Impression, Model, Bite, etc. Object for prosthetic / implant design can be taken with ▪...
  • Page 6 OBJECT SCAN 1 Introduction Recommended System Requirements Items Specification 2GHz or faster 64-bit (x64) Quad Core processor 16GB RAM or more HDD space 1TB HDD or more Resolution 1280 X 800 or more OpenGL 3.2 or higher graphics device Intel 4th Geneneration Core i Series(Haswell) or higher AMD E-Series or A-Series APU Video NVIDIA GeForce 600 Series Graphic Memory 2GB or more...
  • Page 7 OBJECT SCAN 1 Introduction Components Items Figure Q’ty (EA) Object Scan Tray Sponge Disc RAYDENT Converter Installation (USB) RAYDENT Converter License Dongle Key (Optionanl) Impression Holder Digital Tray Start Kit (Optional)
  • Page 8 Precautions before use ▪ The RAYSCAN user manual may differ depending on models of the product. For inquiries about products and manuals, please contact your sales representative or Ray Customer Service of manufacturer. ▪ Before running RAYSCAN, please make sure that the license for Object Scan is activated.
  • Page 9 OBJECT SCAN 2 Precautions ▪ The impressed surface should face toward the mirror on the column. ▪ Impression body should be positioned vertically while acquiring the image. Handle with care of the body of Impression while acquiring the image.
  • Page 10 OBJECT SCAN 2 Precautions Precautions before using the Model and Bite scan ▪ When using the Model and Bite scan, insert a sponge disc in the tray and scan an object on it. ▪ When insert the sponge disc into the tray, check that the sponge disc is fully inserted. If it is not, the surface of the sponge disc will not be leveled.
  • Page 11 OBJECT SCAN 2 Precautions ▪ When placing an object on the tray, ensure that the object is centered on the sponge disc. ▪ When placing an object on the tray, place anterior incisors towards the front of the mirror.
  • Page 12 OBJECT SCAN 3 Installing the Software Installing the Software Installing the RAYDENT Connect and Converter program. Installing the RAYDENT Connect and Converter Do not plug License Dongle Key into PC before installing RAYDENT Connector and Note Converter program. License Dongle Key may not work properly. Figure Description RAYDENT...
  • Page 13 OBJECT SCAN 3 Installing the Software Check the installation information and select the [Install] button to start the installation. Installation in progress. Installation complete. Click the [Finish] button to finish the installation. There are three types of license depending on the function. For additional licensing inquiries, please contact your distributor or customer support.
  • Page 14 OBJECT SCAN 4 How to use RAYSCAN Object Scan How to use RAYSCAN Object Scan Object Positioning 4.1.1 Impression (Maxilla, Mandible) Positioning Figure Description Remove the normal chinrest and add on the Object Scan Tray. Insert the Impression body into the holder.
  • Page 15 OBJECT SCAN 4 How to use RAYSCAN Object Scan Place the holder to the guide holes. Verify the impressed surface faces toward the mirror on the column.
  • Page 16 OBJECT SCAN 4 How to use RAYSCAN Object Scan 4.1.2 Model (Maxilla, Mandible) Positioning Figure Description Remove the normal chinrest and add on the Object Scan Tray. Place the anterior incisors of model on a sponge disc towards the front of the mirror.
  • Page 17 OBJECT SCAN 4 How to use RAYSCAN Object Scan 4.1.3 Bite Positioning Figure Description Remove the normal chin rest and add on the Object Scan Tray. Place the anterior incisors of bite on a sponge disc towards the front of the mirror.
  • Page 18 OBJECT SCAN 4 How to use RAYSCAN Object Scan Object Scanning 4.2.1 Configuration of Object Scan PC Screen Select Object CT modality on the RAYSCANS screen. Triple Tray Model Maxilla Impression Maxilla Impression Mandible Bite Model Mandible Acquisition RAYSCAN α/α+...
  • Page 19 OBJECT SCAN 4 How to use RAYSCAN Object Scan Item Description Patient Info Patient name, ID, gender, date of birth, etc. are displayed. Acquisition Info The selected acquisition mode and conditions are displayed. When acquiring Impression image, you can select calibration data Cal data of the impression materials.
  • Page 20 OBJECT SCAN 4 How to use RAYSCAN Object Scan 4.2.2 Configuring Object Scan Touch Screen Selecting the Object CT modality on RAYSCAN screen. Impression Maxilla Triple Tray Model Maxilla Impression Mandible Bite Model Mandible RAYSCAN α/α+ Touch screen Fig 3...
  • Page 21 OBJECT SCAN 4 How to use RAYSCAN Object Scan Item Description Patient Info Patient name, ID, gender, date of birth, etc. are displayed. Acquisition Info The selected acquisition mode and conditions are displayed. Acquisition Mode Select the acquisition mode. Tube temperature indicator, radiation indicator, ready/cancel.
  • Page 22 OBJECT SCAN 4 How to use RAYSCAN Object Scan 4.2.3 Acquisition Mode Description Figure Description Impression Maxilla Acquire the image of the impression made in the maxilla. Impression Mandible Acquire the image of impression made in the mandible. Impression Triple Tray Acquire the image of impression made in the triple tray.
  • Page 23 OBJECT SCAN 4 How to use RAYSCAN Object Scan 4.2.4 Object Scan Acquisition Refer to “4.1 Object Positioning” to accurately acquires images. The RAYSCAN Studio UI screen is sky blue. Figure Description Select the modality work list (MWL) and then select the [New] button to register a new patient.
  • Page 24 OBJECT SCAN 4 How to use RAYSCAN Object Scan On the Object CT modality screen, select the desired mode (protocol). When scanning impression, select calibration data. Caution: When scanning impression, if impression material and calibration data do not match, there may be a problem in STL converting.
  • Page 25 OBJECT SCAN 4 How to use RAYSCAN Object Scan Object Calibration Procedure When scanning impression body and perform STL converting, proceed with Object scan calibration. If the impression material is changed or added, the calibration should proceed. 4.3.1 Preparation of Calibration Materials...
  • Page 26 OBJECT SCAN 4 How to use RAYSCAN Object Scan 4.3.2 Object Scan Calibration PC screen Figure Description Search bar Searches for MWL lists. It shows the retrieved result. However, the image must be captured Results list with patient ID for Object Calibration. Only impression protocol is output in search result.
  • Page 27 OBJECT SCAN 4 How to use RAYSCAN Object Scan 4.3.3 Image Acquisition Figure Description ObjectScanCalibration desktop. Click the [Acquisition] button. Note: The [Acquisition] button is only active on the Workstation with the Object Scan license activated Scanner is runing. Note:...
  • Page 28 OBJECT SCAN 4 How to use RAYSCAN Object Scan Click the [ready] button to prepare for scanning. After the green light on the exposure switch has been illuminated, continue to press the switch until scanning has been completed. Note: Take care not to release the button during scanning as doing so will stop the scanning process.
  • Page 29 OBJECT SCAN 4 How to use RAYSCAN Object Scan 4.3.4 Calibration Figure Description Select the scanned item and click the [Calibration] button. The Material Config screen is displayed. If nothing is registered, only new addition items will be output, and then you can select and update existing material type.
  • Page 30 OBJECT SCAN 5 How to use RAYDENT Connect How to use RAYDENT Connect RAYDENT Connect screen configuration 5.1.1 Main screen Items Description Order Info. Display the order information list. Image retrieval Patient images can be viewed according to the search conditions. Patient list Display the patient list.
  • Page 31 OBJECT SCAN 5 How to use RAYDENT Connect Run the program to check and edit Smile or Scout pictures of Face Viewer selected patients. 3D Viewer Run the 3D Viewer of the selected patient image. Run the R2Connector of the selected patient image and you can R2Gate run the R2Gate program.
  • Page 32 OBJECT SCAN 5 How to use RAYDENT Connect Items Description Language setting Setting the language displayed in the program. Server setting Setting the server address to import image information. Patient Name Format Setting the format to enter the patient name. Face Viewer Set the path of Face Viewer.
  • Page 33 OBJECT SCAN 5 How to use RAYDENT Connect Export Figure Description Select images to download and copy it to the specified folder. (Up to 10 images can be selected from the list.) Select the folder to download. Once downloaded, Windows Explorer will run. If you do not select a folder, an error will pop-up.
  • Page 34 OBJECT SCAN 5 How to use RAYDENT Connect Face Veiwer If the selected item is Smile or Scout photo file, run Face Viewer. Figure Description Set the Face Viewer path in Settings and it will be active if the type of list is Smile or Scout photo file.
  • Page 35 OBJECT SCAN 5 How to use RAYDENT Connect The [ ] is an undo button. The [ ] is initial button. Press the [Save] button to save the edits.
  • Page 36 OBJECT SCAN 5 How to use RAYDENT Connect 3D Veiwer If the selected item is DICOM or Scout photo file, run 3D Viewer. Figure Description Set the 3D Viewer path in Settings and it will be active if the type of list is DICOM or Scout photo file.
  • Page 37 OBJECT SCAN 5 How to use RAYDENT Connect R2Gate If the selected item is DICOM or Scout+Smile, R2Gate can be linked. Figure Description If you set the R2Gate path in Settings and select Smile from the list type, you must include a Scout picture. You can select more than one Smile.
  • Page 38 OBJECT SCAN 5 How to use RAYDENT Connect STL Converting When a user selects DICOM image, it interworks with RAYDENT Converter in order to convert object scan image to STL. Figure Description Click [Convert to STL] button after selection of STL for conversion. When a user selects Object Scan image which can be converted to STL, the button of [Convert to STL] would be...
  • Page 39 OBJECT SCAN 5 How to use RAYDENT Connect STL Editing When a user selects STL, it interworks with RAYDENT Converter in order to edit STL file. Figure Description Click [Edit STL] button after selection of STL for edit. When a user selects STL file which can be edited to STL, the button of [Edit STL] would be activated.
  • Page 40 OBJECT SCAN 5 How to use RAYDENT Connect Changing configuration Changing the configuration of the program. 5.8.1 Language Setting Figure Description Change the language setting. Select the desired language and click the [Save] button. Click the [OK] button to restart the program automatically.
  • Page 41 OBJECT SCAN 5 How to use RAYDENT Connect Make sure the language is changed. 5.8.2 Setting Server IP Figure Description Set server to import image information. Input server IP, then click [Verify] button. Verify the validity of the server. Click [Yes] button to apply the server IP.
  • Page 42 OBJECT SCAN 5 How to use RAYDENT Connect 5.8.3 Setting Patient Name Format Figure Description Select the formatting of display of patient name. Select the format. Images will be listed in the order of the format. Formats are as follows: [First Middle Last] [Last Middle First] [Last First Middle]...
  • Page 43 OBJECT SCAN 5 How to use RAYDENT Connect Select an executable file in the file selection window.
  • Page 44 OBJECT SCAN 6 The operation of RAYDENT Converter The operation of RAYDENT Converter The screen composition of RAYDENT Converter 6.1.1 Main Screen Items Description Area with tools to edit model such as Brush, Inspection, and Toolbar Cutting Displays list of loaded objects. Has buttons to add, delete, and Object List save as objects.
  • Page 45 OBJECT SCAN 6 The operation of RAYDENT Converter 6.1.2 Setting Screen Items Description When [Setting] button is pressed, the setting window would Setting Button appear on a screen. Allow setting the display language. [Flip Y-Z axis on export] option will save STL files with inverted axis. Setting Window Needs to restart the program when displayed language is changed.
  • Page 46 OBJECT SCAN 6 The operation of RAYDENT Converter How to run RAYDENT Converter It can be converted and loaded a data which is a CT such as Impression, Model, and Bite captured by the protocol of object scan on the RAYSCAN system. 6.2.1 How to run RAYDENT Converter by independently It can run by independence a program and convert to 3D mesh data when a DICOM data captured by the protocol of object scan on the RAYSCAN system has been saved in a...
  • Page 47 OBJECT SCAN 6 The operation of RAYDENT Converter 6.2.2 How to run a program via RAYDENT Connect It can run via RAYDENT Connect by searching a CT image and convert it to 3D mesh data when a data captured by the protocol of object scan on the RAYSCAN system has been saved in a RAYSCAN Server already.
  • Page 48 OBJECT SCAN 6 The operation of RAYDENT Converter Converted 3D mesh data will be shown on the screen. Additional editing can be done after.
  • Page 49 OBJECT SCAN 6 The operation of RAYDENT Converter Object Management 6.3.1 Opening Objects Figure Description Pressing the [ ] button opens up the file selection screen. A user can select data files with extension of STL, OBJ, DCM, or RAW. Click the [Open] button after selecting the desired scan data.
  • Page 50 OBJECT SCAN 6 The operation of RAYDENT Converter In case of DCM/RAW data, scan data is opened after converting to 3D Mesh data. 3D Mesh data is displayed and further editing is enabled. Users can display up to 5 objects regardless of the object type.
  • Page 51 OBJECT SCAN 6 The operation of RAYDENT Converter 6.3.2 Deleting Objects Figure Description Select the objects to be deleted from the list. Press the [ ] button to delete the selected object from the list. Users can delete more than one objects at once.
  • Page 52 OBJECT SCAN 6 The operation of RAYDENT Converter Pressing the [ ] button deletes the selected objects from the list. Users can delete all objects at once. Pressing the [ ] button deletes all objects.
  • Page 53 OBJECT SCAN 6 The operation of RAYDENT Converter 6.3.3 Exporting Objects Figure Description Users can use the export function to save objects separately either during the process of editing or editing is finished. Select the object to export. Pressing the [ ] button displays a file dialogue to enter the name to save the object as.
  • Page 54 OBJECT SCAN 6 The operation of RAYDENT Converter Press the [Select] button on the right for each object to designate the directory and name to save as. If the designated directory overlaps with directory of another object, the directory is turned red and a warning message is displayed.
  • Page 55 OBJECT SCAN 6 The operation of RAYDENT Converter Users can export currently loaded objects all at once. Pressing the [ ] button opens up a dialogue to designate directories to all objects on the list. Set the directories for each object so that the directories do not overlap with one another.
  • Page 56 OBJECT SCAN 6 The operation of RAYDENT Converter Object Editing 6.4.1 Rotation, move, and rescale of object Figure Description Users can rotate an object when they move a mouse everywhere holding the right button. User can move an object when they move a mouse everywhere holding the [mouse left + right] button.
  • Page 57 OBJECT SCAN 6 The operation of RAYDENT Converter 6.4.2 Type of Object Figure Description It is loaded with up way when a user opens maxillary data such as Impression and Model scan. It is loaded with down way when a user opens mandibular data...
  • Page 58 OBJECT SCAN 6 The operation of RAYDENT Converter 6.4.3 Changing Object Scan Type Figure Description Users can change the scan type of the loaded object. Hovering mouse over the object to edit on the list displays the [ ] button. Click the button.
  • Page 59 OBJECT SCAN 6 The operation of RAYDENT Converter 6.4.4 Brush tool Figure Description Select the object to edit and press the ] button to enter the Brush Mode It would show a selectable region on an object on a screen when a user moves mouse point on an object after choosing ] button.
  • Page 60 OBJECT SCAN 6 The operation of RAYDENT Converter Select all connected area by double- clicking [Left Mouse Button] on a particular area. Move over the selected area while pressing [Ctrl + Left Mouse Button] to deselect the area. [Select All] : Select all objects. [Clear All] : Clear selected area.
  • Page 61 OBJECT SCAN 6 The operation of RAYDENT Converter Select the particular area of the object and press the [Clip] or [Delete] button. [Clip] : Leaves only the selected area. [Delete] : Deletes the selected area. The object on the left is the result after pressing the [Clip] button for the selected object in Step 4.
  • Page 62 OBJECT SCAN 6 The operation of RAYDENT Converter 6.4.5 Inspecting Figure Description Pressing the [ ] button after selecting the object examines the parts that need inspection. Controls such as [ ] appear at parts that need inspection on the object. Users can press the [Select All] button to select all or select individual inspection areas.
  • Page 63 OBJECT SCAN 6 The operation of RAYDENT Converter It can select to undefined area through the manual inspection tool. It can select the part of needed repairing. Click [Add] button after choosing some parts of needed repairing. When select [Repair] of [Remove] buttons after all selection, repairing task would be started.
  • Page 64 OBJECT SCAN 6 The operation of RAYDENT Converter If additional work needs to be done after inspection, users can repeat the same procedure. Check the repaired object.
  • Page 65 OBJECT SCAN 6 The operation of RAYDENT Converter 6.4.6 Cutting Provides the function to cut the object into two or more pieces. Figure Description Press the [ ] button to use the cut tool. Mouse-left button allows to add a cutting- point.
  • Page 66 OBJECT SCAN 6 The operation of RAYDENT Converter Click [ ] button to separate the area from the object. To delete a specific part of the cut object, select the area to be deleted with the brush tool. Users can freely brush since it does not select anything outisde of the separated area.
  • Page 67 OBJECT SCAN 6 The operation of RAYDENT Converter 6.4.7 Inverting Figure Description Select the object to invert. Pressing the [ ] button inverts the object.
  • Page 68 OBJECT SCAN 6 The operation of RAYDENT Converter 6.4.8 Separating the Maxilla and Mandible This section provides the steps to separate the maxilla and mandible. If the corresponding button has not been activated, please check if the object has been precisely separated. Figure Description Open and select the object to divide into...
  • Page 69 OBJECT SCAN 6 The operation of RAYDENT Converter Use the brush or cut tool to separate the edge. While selecting entire object, separate the connected edge of two occlusal surfaces by deselecting using the [Ctrl + Left Mouse Button]. When occlusal surfaces completely separated, the [...
  • Page 70 OBJECT SCAN 6 The operation of RAYDENT Converter Find the connected place of two occlusal surfaces and cut with the cut tool. When occlusal surfaces completely separated, the [ ] button is activated. When occlusal surfaces separated, invert the objects by pressing the invert button.
  • Page 71 OBJECT SCAN 6 The operation of RAYDENT Converter Select the part corresponding to maxilla by clicking the [Left Mouse Button]. Select part corresponding mandible by clicking the [Right Mouse Button]. Users can differentiate the selected maxilla and mandible with the displayed text.
  • Page 72 OBJECT SCAN 6 The operation of RAYDENT Converter When exporting, maxilla and mandible are separated automatically to save as separate STL files.
  • Page 73 OBJECT SCAN 6 The operation of RAYDENT Converter 6.4.9 Aligning Objects 6.4.9.1 Alignment of Two Objects Figure Description Open or select two objects from the list to align. Editing can be done if needed. Pressing the [ ] button enters Two Objects Align mode, and the initially selected object is set as the fixed reference.
  • Page 74 OBJECT SCAN 6 The operation of RAYDENT Converter Users can press the [ ] button to swap moving target with fixed reference. Select at least 3 and at most 10 alignment points on the moving target and the fixed reference. Alignment points should be selected in the same order for both left and right for alignment of two objects.
  • Page 75 OBJECT SCAN 6 The operation of RAYDENT Converter To select alignment points again, press the [ ] button to clear all selected alignment points. After selecting the alignment points, press the [ ] button to start aligning. If the alignment did not work properly, go back to Step 5 and try again.
  • Page 76 OBJECT SCAN 6 The operation of RAYDENT Converter 6.4.9.2 Alignment of Bites It is recommended to align from partial bites, separately made for left and right, than with full bites using 3~4 teeth. 6.4.9.2.1 Alignment of Full Bites Figure Description Open maxilla/mandible/bite scan data or select three objects (maxilla, mandible, bite) from the object list.
  • Page 77 OBJECT SCAN 6 The operation of RAYDENT Converter Users can use the scroll bar to adjust the opacity of two objects to align. Press the [ ] button on the top right for help. Select at least 3 and at most 10 alignment points on the moving target and the fixed reference.
  • Page 78 OBJECT SCAN 6 The operation of RAYDENT Converter Alignment points should be selected in the same order for both left and right for alignment of two objects. If not done properly, the alignment may not work. For maxilla alignment, align by moving the bite to the maxilla, which is the fixed reference.
  • Page 79 OBJECT SCAN 6 The operation of RAYDENT Converter Clicking the [ ] button on the top enters the mandible alignment mode. For mandible alignment, align by moving the mandible to the bite, which is the fixed reference. Select at least 3 and at most 10 alignment points on the moving target and on the fixed reference, as done for the maxilla alignment.
  • Page 80 OBJECT SCAN 6 The operation of RAYDENT Converter Users can use the scroll bar to adjust the opacity of the maxilla/mandible/bite. The figure on the left shows the result after adjusting the opacity of the bite. 6.4.9.2.2 Alignment of Partial Bites Figure Description Users can align left and right partial bites,...
  • Page 81 OBJECT SCAN 6 The operation of RAYDENT Converter For the desired direction (left or right), select at least 3 and at most 10 alignment points. Pressing the [ ] button aligns the bites based on the selected alignment points. To align the other side, press the ] button to clear the alignment points.
  • Page 82 OBJECT SCAN 6 The operation of RAYDENT Converter Press the [ ] button to see the alignment result based on the selected alignment points. Press the [ ] button to align the mandible. For the mandible alignment, align by moving the mandible to the bite, which is the fixed reference.
  • Page 83 OBJECT SCAN 6 The operation of RAYDENT Converter Press the [ ] button to see the alignment result. Users can use the scroll bar to adjust the opacity of the maxilla/mandible/bite. The figure on the left shows the result after adjusting the opacity of the bite.
  • Page 84 OBJECT SCAN 6 The operation of RAYDENT Converter 6.4.10 Undo, Redo, Initialization 6.4.10.1 Undo Figure Description Users can undo a certain action. If there is any action that can be undone, the [ ] button is activated, and pressing the button goes back to the state before the last action.
  • Page 85 OBJECT SCAN 6 The operation of RAYDENT Converter If a job can be redone, [ ] button is activated, and pressing the button redos the last undone action. 6.4.10.3 Initialization Figure Description Users can revert the object back to the original state before editing.
  • Page 86 Ray Co., Ltd. All rights reserved.