2024 – Jurop – Azzano Decimo (PN) Reproduction, electronic storage and dissemination, even partial, are wholly prohibited. Jurop reserves the right to modify the products described in this manual without prior notice. Any product names mentioned herein are the trademarks of their respective owners.
Each RV SYSTEM unit has an identification plate, in which the following are detectable: code, model, serial number (the same as the vacuum/pressure pump) and year of construction. Fig. 1.1 Each RV vacuum/pressure pump can only be installed if it has an identification plate. Jurop SpA . +39 0434 636811 F . +39 0434 636812 http://www.jurop.it Via Crosera n°...
Request for spare parts Use only genuine spare parts for maintenance and repairs. To order spare parts, provide the following details. a) Unit type RV 360 SYSTEM b) Serial number (see plate): J90001 c) Name (see list of spare parts):...
Avoid suctioning of toxic materials and flammable or explosive gases as the internal components can reach high temperatures. Do not use the unit beyond its intended operating limits (see paragraph. 2.3): risk of breakage and possible transmission damage. Jurop SpA . +39 0434 636811 F . +39 0434 636812 http://www.jurop.it...
Check that there is space in height to handle the module, once lifted. Before lifting the module completely, make sure that transport stability is guaranteed. Do not stand under the machine when it is lifted during the installation. Jurop SpA . +39 0434 636811 F . +39 0434 636812 http://www.jurop.it...
In order to achieve uniform motion of the driven axis, the following conditions must be met (see Fig. 4.3): Equal joint angles α and α1 of the two joints; The inner forks of the joints must be coplanar; Driven shaft and coplanar conductors. Jurop SpA . +39 0434 636811 F . +39 0434 636812 http://www.jurop.it Via Crosera n°...
Page 11
In any case, the installation, by the final installer, must meet current accident prevention regulations. OIL HYDRAULIC TRANSMISSION The unit can be supplied with a hydraulic motor instead of a gearbox. Performance data are given below. RV 360 RV 520 Max. Vacuum 0,5 bar rel Max.
The alarm (available upon request) is composed of a blinking light and a warning buzzer that have to be connected to the thermostat (sensor). It is available at 12V or 24V. Consider the thermostat characteristics. Voltage from 6V to 24V with CC, from 6V to 12V with AC. Jurop SpA . +39 0434 636811 F . +39 0434 636812 http://www.jurop.it Via Crosera n°...
Page 13
OVERHEATING WARNING DEVICE Fig. 4.5 If the temperature exceeds 180°C during pressure operation, check the filter. A dirty filter will not allow air to pass to the pump. Jurop SpA . +39 0434 636811 F . +39 0434 636812 http://www.jurop.it Via Crosera n°...
Wear the required PPE (e.g. gloves, etc.) during maintenance. All disassembly and reassembly operations must be done exclusively by qualified, trained personnel. JUROP S.p.A. provides technical support for any information. Maintenance operations that require complete disassembly of the RV vacuum/pressure pump should be performed at an authorized JUROP service center.
Page 15
Checking the vanes wear Unscrew the vanes wear check-plug on the front flange. VANES WEAR CHECK-PLUG Fig. 5.2 Jurop SpA . +39 0434 636811 F . +39 0434 636812 http://www.jurop.it Via Crosera n° 50 15 / 28 e-mail: info@jurop.it...
The discharge silencer (when assailed by pump discharge airflows) is subjected to the passage of high-temperature air that may cause overheating (over 90°C). Jurop SpA . +39 0434 636811 F . +39 0434 636812 http://www.jurop.it Via Crosera n°...
Under ordinary use conditions, we recommend cleaning the filter on a weekly basis. In the event of heavy duty conditions, clean (or replace) the cartridge every time the line performance appears to be compromised. The filter must be cold cleaned. Jurop SpA . +39 0434 636811 F .
We recommend verifying the operation of the overflow valve periodically, ensuring that the floating ball can move freely. Remove cover and basket, checking seals and gaskets for wear. Replace if necessary. Clean and reinstall the previously removed components. Jurop SpA . +39 0434 636811 F .
Page 19
The final manufacturer should provide the necessary space for maintenance activities on the pressure relief valves. Jurop SpA . +39 0434 636811 F . +39 0434 636812 http://www.jurop.it...
The pressure gauge measures the pressure of the conveyed gas (in this case air) and is connected to the air filter. When removing or disassembling the unit, pay attention to the vacuum gauge hose. Jurop SpA . +39 0434 636811 F .
Page 28
Revision date Drawn up by Viewed by RV SYSTEM 19-01-2024 U.T. A.T. Jurop SpA Via Crosera, 50 33082 Azzano Decimo, PN (ITALY) Tel. +39 0434 636811 Fax. +39 0434 636812 http://www.jurop.it e-mail: info@jurop.it urop SpA reserves the right to modify the products described in this manual without prior notice.