Download Print this page

Advertisement

Quick Links

Packing List
In addition to this guide, the package includes the following items:
PM-4324P /
PM-4324P-MTCP
Technical Support
service@icpdas.com
www.icpdas.com
 For Desktop Web
PM-4324P Quick Start
Screw Driver * 1
Resources
How to search for drivers, manuals and
spec information on ICP DAS website.
 For Mobile Web
Model Name
Model Name
v1.0, February 2025
P1

Advertisement

loading
Need help?

Need help?

Do you have a question about the PM-4324P and is the answer not in the manual?

Questions and answers

Summary of Contents for ICP DAS USA PM-4324P

  • Page 1 PM-4324P Quick Start v1.0, February 2025 Packing List In addition to this guide, the package includes the following items: PM-4324P / PM-4324P-MTCP Screw Driver * 1 Resources How to search for drivers, manuals and Technical Support spec information on ICP DAS website.
  • Page 2: Caution And Warning

    1.1.Caution & Warning The meter contains hazardous voltages, and should never be disassembled. Failing to follow this practice will result in serious injury or death. Any work on or near energized meters, meter sockets, or other metering equipment could induce a danger of electrical shock.
  • Page 3: Installation

    Please ensure that the arrow direction marking on the CT aligns with the current flow direction (K→L). Note: it must be in the same direction. Connect the voltage input terminal N C B A. for PM-4324P, in the three phase order as follows on N C B A. 2.2.Voltage Input 1.
  • Page 4: Current Input

    2.3.Current Input 1. The external CT’s are fragile, please handle with care. 2. The current input of PM-4324P series is in mV range. The other CT’s, for example, from panel will damage the instrument due to its large current (around 5A) 3.
  • Page 5 2.4.Wiring  1P2W-1CT  1P3W-2CT...
  • Page 6  3P3W-2CT  3P3W-3CT DIP switch: Wiring mode SW 9 SW 10 3P3W-3CT  3P4W-3CT...
  • Page 7 DIP switch: Wiring mode SW 9 SW 10 3P4W-3CT...
  • Page 8 9600 bps 125k (Default) bps 19200 (Default) bps 250k bps 38400 bps 500k bps 115200 bps 1M bps PM-4324P:Select the different wiring mode (Please select the Software setting, if 1P2W-1CT or 1P3W-2CT is used) Models PM-4324P/PM-4324P-MTCP Wiring SW 9 SW 10...
  • Page 9: Ethernet Setting

    2.6.Add the Bias Resistor on RS-485 Network for stable signal The RS-485 master is required to provide the bias for PM-4324P series. Otherwise, the tM-SG4 or SG-785 should be added to provide the bias. All ICP DAS controllers and converters provide the bias.