Create Array Screen - Compaq 219700-001 - ProLiant - 1500 Reference Manual

Array controller
Hide thumbs Also See for 219700-001 - ProLiant - 1500:
Table of Contents

Advertisement

5-25

Create Array Screen

In this screen, all of the available drives attached to the selected controller are
listed in the Port columns. The rows in the columns correspond to the SCSI ID
of the drives.
To create an array, select the drives to be part of the array, then click the
Assign Drive to Array button. To assign a spare, select the drive to be the
spare and then click the Assign Spare to Array button.
Always group physical drives of the same size. If you mix drive sizes, the
SMART-2DH Array Controller treats all the drives as the same size as the
smallest drive in the array. This results in wasted capacity in the larger drives.
To increase performance, select drives from both ports and install the correct
drives on both ports before running the Array Configuration Utility.
Figure 5-19. Create Array screen
SMART-2DH Array Controller Reference Guide
Writer: Pamela King Project: SMART-2DH Array Controller Reference Guide Comments: 295469-002
File Name: F-CH05.DOC Last Saved On: 2/27/98 11:38 AM
COMPAQ CONFIDENTIAL - NEED TO KNOW REQUIRED

Hide quick links: