Configuring The Controller - Compaq 219700-001 - ProLiant - 1500 Reference Manual

Array controller
Hide thumbs Also See for 219700-001 - ProLiant - 1500:
Table of Contents

Advertisement

4-4
Running the System Configuration Utility

Configuring the Controller

1. Edit these parameters for SMART-2DH Controller:
Under Advanced Features:
Press Enter to select the parameter to edit.
To help you make the correct selections, explanations of these
parameters are included below.
Controller Order
Select the order in which you want this SMART-2DH Controller to be
recognized. All hard disk controllers, including the integrated
controller on the system board, must be assigned a unique order
number.
When installing a SMART-2DH Controller, you must determine if the
boot disk is to be handled by a SMART-2DH Controller or the
integrated SCSI controller. If this SMART-2DH Controller will be the
primary controller, choose First; a Configuration Changes screen is
presented, indicating that if you accept this change, the integrated SCSI
controller will be changed to Second automatically. Press Enter to
accept these changes.
Writer: Pamela King Project: SMART-2DH Array Controller Reference Guide Comments: 295469-002
Controller Order
Online Recovery Server Status
PCI Memory Overlay Setting
First
The primary disk controller that contains the boot disk.
The first disk drive on this controller is the one that the
server will boot from.
Second
The second disk controller.
.
.
Fifteenth The fifteenth disk controller.
File Name: E-CH04.DOC Last Saved On: 2/27/98 11:28 AM