Text
E2113
Mem mirror OFF
on DIMM ## &
##. Power
cycle AC
I1910
Intrusion
detected.
Check chassis
cover.
I1912
System Event
Log full.
Review &
clear log.
I1920
iDRAC6 Upgrade
Successful
W1228
RAID
Controller
battery
capacity <
24hr.
W1627
Power required
> PSU wattage.
Check PSU and
config.
40
About Your System
Causes
The system BIOS has
disabled memory
mirroring because it has
determined one half of the
mirror has had too many
errors. "## & ##"
represents the
memory-module pair
implicated by the BIOS.
System cover has been
removed.
The SEL is full of events
and is unable to log any
more.
Optional iDRAC6 has
been upgraded
successfully.
Warns predictively that
the RAID battery has
less than 24 hours of
charge left.
The system configuration
requires more power
than what the power
supply can provide.
Corrective Actions
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Troubleshooting
System Memory" on
page 177.
Information only.
Check the SEL for details
on the events, then clear
the SEL.
Information only.
Allow RAID battery
to charge to greater
than 24 hours of
sustained charge.
If problem persists,
replace RAID battery.
See "Installing the RAID
Battery" on page 147.
Turn off power to the
system, reduce the
hardware configuration or
install higher-wattage
power supplies, and then
restart the system.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents