Installing A Non-Redundant Power Supply; System Memory - Dell PowerEdge R510 Hardware Owner's Manual

Server systems
Hide thumbs Also See for PowerEdge R510:
Table of Contents

Advertisement

1
bracket
3
power supply
5
optical drive power cable
7
SATA power cable

Installing a Non-Redundant Power Supply

NOTE:
This section is applicable to systems with cabled hard drives only.
1 Open the system. See "Opening the System" on page 87.
2 Slide the new power supply into the chassis until the power supply is fully
seated, install a bracket at the back of the power supply, and tighten the
screws to secure the power supply with the chassis. See Figure 3-18.
3 Connect the power cable to the power supply.
4 Connect all the power cables to the system board, hard drive(s),
and optical drive.
5 Plug the cable into a power outlet.
6 Replace the system cover. See "Closing the System" on page 89.
7 Turn on the system and attached peripherals.

System Memory

Your system supports DDR3 registered DIMMs (RDIMMs) or unbuffered
ECC DIMMs (UDIMMs). Single and dual-rank DIMMs can be 1067- or
1333-MHz, and quad-rank DIMMs can be 1067-MHz.
The system contains eight memory sockets split into two sets of four sockets,
one set per processor. Each four-socket set is organized into three channels.
Two DIMMs for channel 0 and a single DIMM for channel 1 and 2. The first
socket of each channel is marked with white release levers.
114
Installing System Components
2
screws (2)
4
power cable 8 pins
6
power cable 24 pins