Dell PowerEdge R510 Hardware Owner's Manual page 38

Server systems
Hide thumbs Also See for PowerEdge R510:
Table of Contents

Advertisement

Code
Text
E201A
SuperIO
failure.
Power cycle
AC.
E201B
Keyboard
Controller
error.
Power cycle
AC.
E201C
SMI
initialization
failure.
Power cycle
AC.
E201D
Shutdown test
failure. Power
cycle AC.
E201E
POST memory
test failure.
Check DIMMs.
E2020
CPU
configuration
failure. Check
screen
message.
38
About Your System
Causes
SIO failure.
Keyboard
controller failure.
System management
interrupt (SMI)
initialization failure.
BIOS shutdown test
failure.
BIOS POST memory test
failure.
Processor configuration
failure.
Corrective Actions
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 199.
Remove AC power to the
system for 10 seconds and
restart the system.If the
problem persists,
see "Getting Help" on
page 199.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 199.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 199.
See "Troubleshooting
System Memory" on
page 177.
If the problem persists,
see "Getting Help" on
page 199.
Check screen for specific
error messages.
See "Troubleshooting
Processors" on page 186.

Hide quick links: