OPERATOR'S GUIDE
Infusion Workstation
Introduction
Great care has been taken in the design and manufacture of the Module
+
®
MVP
MS Orchestra
, a volumetric infusion device.
According to the number of intravenous infusions needed, at any
combination, up to 8 Module MVP
onto the Base Intensive Orchestra
The configuration of Orchestra
working conditions of medical teams, thus increasing patient safety.
+
The Module MVP
provides you with superior flexibility as it can also be
set as a standalone pump thanks to its securing clamp and standard
power cable.
The use of this material requires great care. The user must be able to handle the instrument
properly and must know how to fully operate.
Please read the operator's guide carefully before putting the device into use. Please refer to the
®
Base A Orchestra
or Base Intensive Orchestra
with a Base.
Module MVP
+
(and/or Module DPS) can be fitted
®
®
or Base A Orchestra
.
®
provides overall improvement in the
®
Operator's Guides, prior to any use of Modules

Table of contents

1.
Operations for use ........................................................................ 2
2.
Advanced functions ...................................................................... 4
+
3.
+
4.
MS - Performances.............................................. 10
+
5.
MS - Technical characteristics........................... 11
6.
Configuration menu .................................................................... 13
7.
Precautions to be taken.............................................................. 15
8.
environment ........................................................................................... 16
9.
Maintenance recommendations ................................................ 18
10.
Function with the internal battery ............................................. 19
11.
Accessories ................................................................................. 20
12.
Disposable................................................................................... 21
13.
Conditions of guarantee............................................................. 22
14.
Useful addresses ........................................................................ 24
+
MS

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Orchestra MVP+ MS and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Fresenius Kabi Orchestra MVP+ MS

  • Page 1: Table Of Contents

    OPERATOR’S GUIDE Infusion Workstation Module MVP Introduction Table of contents Operations for use ................ 2 Advanced functions ..............4 Great care has been taken in the design and manufacture of the Module Module MVP MS - Internal safety features......... 7 ®...
  • Page 2: Operations For Use

    Operations for use 1.1. Installation of the Module MVP 1.2. Tubing set installation Choose from the range of the MS infusion sets proposed page 20, the one that best suits the protocol you are using. The 1.1.1. On the Base infusion set must be in normal temperature conditions: +18°/+30°C.
  • Page 3 Place the container out 1.4. Information during infusion of the Orchestra® Infusion Workstation. Mains power operation / Alarm status (red) Battery power operation Prealarm status (orange) Form a loop The container must Module position between the be placed from 20 Flow rate (ml/h) Infusion mode type door and the...
  • Page 4: Advanced Functions

    Advanced functions When activated in the configuration menu, all advanced functions can be reached by pressing Then, press to reach required item and to enter desired screen. Pressure Loading dose Bolus Bolus Total volume Ramp up / Down Secondary Secondary Bat.autonomy Sequential Pause...
  • Page 5 2.5. Secondary infusion 2.6. Programming pause Definition 2.5.1. Press twice, or reach programming pause with key. Hold the primary infusion with the key, and close the upper Select pause duration in minutes and hours with clamp of the primary line. Connect the secondary line on the luer Confirm with .
  • Page 6: Sequential Programming

    2.10. Sequential programming 2.11. Micro Infusion Flow Rate From 1 up to 20 infusion sequences can be defined in volume to When the micro infusion flow rate is activated (see Configuration infuse and rate of infusion. Pause periods (Stop) or KVO periods menu), a decimal digit is displayed both for flow rate and for volume.
  • Page 7: Module Mvp + Ms - Internal Safety Features

    Module MVP MS - Internal safety features Module MVP+ as well as Base has a continuous inspection system that functions as soon as the pump is in use. Any internal failure or anomaly detected will be immediately displayed. Nevertheless, the qualified personnel in your establishment or our After-Sales Department should always be notified of any abnormal function where no specific cause can be found.
  • Page 8 Message on LCD display Meaning Causes Actions to do  Upstream pressure in line is Check container. Upstream occlusion Alarm. occlusion Infusion stops. too low. Check roller clamp.  Empty bag. Check container height.  Roller clamp closed. Check air inlet cap (if bottle is used). ...
  • Page 9: Quick Check

    3.2. Quick check This test is recommended or mandatory (in case of in-force law). It allows a complete alarm and safety features check of the Module MVP+ MS (no patient connected). Serial numbers (ID/N): Base A _______________________________ Base Intensive _______________________________ Module MVP+ MS _______________________________ Date: _____ / ____ / ____ Department ____________________________ Name ____________________________...
  • Page 10: Module Mvp Ms - Performances

    Module MVP MS - Performances 4.1. Flow rate available from 4.8. Change set interval keyboard selection We recommend to change the set from MS range (PVC and PVC free) after 24 hours and/or 2.5 litters for very tight flow rate accuracy (check From 1 to 1000 ml/h, 1 ml/h increment.
  • Page 11: Ms - Technical Characteristics

    Module MVP MS - Technical characteristics 5.1. External power supply 5.4. Device materials : all components are Latex free 5.1.1. Via the Base Housing Front et rear case: ABS 7.15 Volts DC mini - Power  6 Watts Continuous voltage Polyamid Door (normal consumption) 10 Watts maxi...
  • Page 12 Curves 5.8. Trumpet curves demonstrate the evolution of the minimum and maximum variance of the PUMP / SET combination versus flow rate. The test protocol used to obtain these results is described in the EN 60 601-2-24. For further information, please refer to this publication. Use these curves to determine the accuracy depending upon your infusion protocol / drug / dilution.
  • Page 13: Configuration Menu

    Configuration menu Fresenius Kabi recommends the presence of its qualified personnel or of a member of the Technical Department of your establishment to help you implement the configuration procedures you wish to choose. Note: press to cancel modification at any time - Press OFF to leave configuration mode at any time.
  • Page 14 6.3. Ward setting Ward setting Enter code with , and confirm by pressing (pre-set code is 200). Ward setting Select required item with , and enter in required item by pressing Code Ward name Select desired letter with . Shift to next letter with Rea-Cardio ----- Confirm setting by pressing...
  • Page 15: Precautions To Be Taken

    During the change of the infusion parameters, if the user does not confirm the new setting, a non-validation time-out alarm occurs. Fresenius Kabi will not be liable for any damages or claims, The values displayed are then : medical or otherwise, of any nature whatsoever, whether direct or - at start-up : the values resulting from the ward setting configuration / consequential, caused by improper use of this device.
  • Page 16: Guidance And Manufacturer's Declaration On Electromagnetic Environment

    Guidance and manufacturer's declaration on electromagnetic environment The Module MVP MS has been tested and found to comply with the applicable standards for electromagnetic Compatibility for Medical Devices. These standards are designed to provide adequate immunity to prevent undesirable operation of the Module MVP MS , as well as a limitation of emissions from the device that may cause undesirable interference to other equipment.
  • Page 17 8.3. Guidance and manufacturer’s declaration – electromagnetic immunity TABLE 204 The Module MVP+ MS is intended for use in the electromagnetic environment specified below. The user of Module MVP MS should make sure it is used in such an environment. IEC 60601-1-2 Compliance level Immunity test...
  • Page 18: Maintenance Recommendations

    Please contact the appropriate service, responsible for cleaning and Fresenius Kabi is not liable for loss or damage to the device during disinfecting products, in your establishment for further details. transport to our After-Sales Department.
  • Page 19: Function With The Internal Battery

    10. Function with the internal battery The Module MVP+ and the Base contains an internal battery which automatically takes over when the mains supply is disconnected and ensures normal function with no loss of the programmed data. Operation from the battery is visualised by the battery indicator on Module.
  • Page 20: Accessories

    11. Accessories ® Fresenius Kabi recommends the use of Orchestra Infusion Workstation range accessories. Multifix 4 - Cat # 073804 ® Orchestra Mobile Stand Multifix 6 - Cat # 073809 Multifix 8 - Cat # 073805 Whatever maybe the This system simplifies transport and fastens ®...
  • Page 21: Disposable

    12. Disposable 12.1. MS range MS 95 - Cat # 072995. Tubing set with 150 ml graduated burette and 15 µ filter. “MS Set” set type. The MS range is made of biocompatible plastic materials. Single use, with 5-year shelf life. MS 05 - Cat # 072905.
  • Page 22: Conditions Of Guarantee

    13. Conditions of guarantee Fresenius Kabi guarantee that this product is free from defects in material and workmanship during the period defined by the conditions of sale accepted , except for the batteries and accessories. To benefit from the materials and workmanship guarantee from our After-...
  • Page 23 Notes 2832-1_nu_module_mvp_plus_ms_eng2_271009.doc - 23 -...
  • Page 24: Useful Addresses

    As standards and equipment change from time to time, the features shown and described in this document must be confirmed by our departments. This document may not be reproduced in whole or in part without the written consent of Fresenius Kabi. ®...

Table of Contents