Summary of Contents for Seneca ZE-4DI-2AI-2DO

  • Page 1 Via Austria, 26 – 35127 – PADOVA – ITALY Tel. +39.049.8705355 - 8705359 - Fax +39.049.8706287 This document is the property of SENECA srl. Copies and reproduction are prohibited unless authorised. The con- tent of this document corresponds to the described products and technologies.
  • Page 2: Technical Specifications

    AI 2 Supply 1500 V 1500 V 1500 V emperature Humidity ENVIRONMENTAL Altitude: CONDITIONS Storage temperature: Protection degree: ASSEMBLY CONNECTIONS micro USB POWER SUPPLY (ZE-4DI-2AI-2DO Z-4DI-2AI-2DO) (ZE-2AI) DIGITAL INPUTS only ZE-4DI-2AI-2DO Z-4DI-2AI-2DO COUNTERS: only ZE-4DI-2AI-2DO Z-4DI-2AI-2DO DIGITAL OUTPUTS only ZE-4DI-2AI-2DO Z-4DI-2AI-2DO...
  • Page 3: Preliminary Warnings

    PRELIMINARY WARNINGS WARNING ATTENTION ge the WARNING Important: Obstructing ventilation slots with any object is prohibited. Installing the module next to devices that generate heat is prohibited. SETTING THE DIP-SWITCHES DIP-Switch status SW1 POSITION SW1 POSITION POSITION BAUD ADDRESS TERMINATOR RATE LEGEND From...
  • Page 4: Installation Regulations

    CONFIGURATION OF FACTORY SETTINGS ModBUS CONNECTION RULES Diagram 1 Module 4 Module 3 Derivation Bus length length Module 1 Module 2 Module 5 1200 m Bus length Ld= derivation length INSTALLATION REGULATIONS Insertion on the MODULE DIN rail Insertion in the DIN rail DIN rail...
  • Page 5 Back connector (IDC 10) Power Suppl y AC / + RS485 GND Power Suppl y AC / - RS485 A IDC 10 RS485 B Z-PC-DINAL2-17.5 accessory use Ground L / A USB PORT 115200,8,N,1 Android APP PC software MICROB MICROB -A-- MICROO TG Check that the device in question is included in the list of products supported by the Easy Setup APP in the store.
  • Page 6: Electrical Connections

    Voltage 1 12V 4GND 4GND 5AI1 5AI1 5A I1 6AI2 6AI2 6A I2 manual DIGITAL INPUTS (ONLY ZE-4DI-2AI-2DO and Z-4DI-2AI-2DO) 20mA 15 +12V 15 +12V 15 +12V Max 24V 14 DI2 14 DI2 14 DI2 13 DI1 13 DI1 13 DI1...
  • Page 7: Module Layout

    Single module dimensions LxHxD: Weight: Enclosure: Double module dimensions LxHxD: Weight: Enclosure: LED SIGNALS ON THE FRONT PANEL (ZE-4DI-2AI-2DO) STATUS MEANING IP/ PWR (Green) Module powered and IP address acquired Module powered and IP address not yet IP/ PWR (Green)
  • Page 8: Contact Information

    LED SIGNALS ON THE FRONT PANEL (Z-4DI-2AI-2DO) STATUS MEANING PWR (Green) Module powered Transmission and reception of data on at least Tx/ RX (Red) Flashing FAIL (Red) Flashing Outputs in fail condition LED SIGNALS ON THE FRONT PANEL (ZE-2AI) STATUS MEANING IP/ PWR (Green) Module powered and IP address acquired...

This manual is also suitable for:

Z-4di-2ai-2doZe-2ai