PERCo TTD-08A Assembly And Operation Manual

Electromechanical box tripod turnstile with automatic anti-panic arms
Hide thumbs Also See for TTD-08A:

Advertisement

Quick Links

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TTD-08A and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for PERCo TTD-08A

  • Page 2 Electromechanical Box Tripod Turnstile with Automatic Anti-Panic Arms TTD-08A Assembly and Operation Manual...
  • Page 3: Table Of Contents

    CONTENTS APPLICATION ......................3 OPERATION CONDITIONS ..................3 TECHNICAL SPECIFICATIONS ................. 4 DELIVERY SET ......................5 Standard delivery set ..................... 5 Optional equipment supplied on request ............... 5 PRODUCT DESCRIPTION ..................6 Main features ......................6 Design ........................6 5.2.1 Turnstile housing ....................
  • Page 4: Application

    Manual carefully, and this quality product will provide many years of trouble-free use. Assembly and Operation Manual (hereinafter - the Manual) for the TTD-08A electromechanical tripod turnstile with automatic anti-panic folding arms contains data that is necessary for the most full use of operating advantages of the turnstile as well as chapters on packaging, installation and maintenance.
  • Page 5: Technical Specifications

    Overall dimensions (L × W × H) ............1166×750×1016 mm Net weight of the turnstile .................. max. 70 kg Figure 1 – Overall dimensions of the TTD-08A turnstile The power consumption can rise to 72W within 5 sec. after power up or at taking off the Fire Alarm signal.
  • Page 6: Delivery Set

    TTD-08A Electromechanical Box Tripod Turnstile DELIVERY SET 4.1 Standard delivery set Basic equipment: Turnstile housing with hub and barrier arms ............1 S2.5 allen key to a housing top cover ..............1 RC panel with cable ....................1 Installation tools: Self-adhesive cable tie mount ................
  • Page 7: Product Description

    Assembly & Operation Manual PRODUCT DESCRIPTION 5.1 Main features • The turnstile is designed either for indoor application or outdoor (see Clause 2). Turnstile housing is produced from high quality stainless steel with ABS plastic covers. • The turnstile plastic side covers are radio transparent that allows concealed mounting of the ACS readers inside the turnstile housing.
  • Page 8: Turnstile Housing

    (3). Fastening of the cap to the housing is accomplished with the help of driver screw (4). During operation of the turnstile top cover has to be locked. Under the top cover there is a bracket with control panel PERCo-CLB.140 (further – control panel) and remote connector block XS1.
  • Page 9: Indication Modules

    Assembly & Operation Manual Both front sides of the turnstile housing feature indication modules (8, 9). Top covers are fixed fast on side walls (6, 7). Under side walls there are turnstile indication boards. On side walls there are extra indicators of passage direction, passage indication boards are located under them.
  • Page 10: Control Logic Board

    TTD-08A Electromechanical Box Tripod Turnstile Figure 4 – RC panel overall view 1, 2, 3 – buttons LEFT, RIGHT, STOP for setting the passage mode; 4, 5 – green indicators «Left», «Right»; 6 – red indicator «Stop», 7 – RC cable 5.2.4...
  • Page 11 Assembly & Operation Manual Table 1 – Contacts of the connector blocks № Item Function of the contact Connector blocks of the CLB.140 XT1L (In) +12V Output of power supply for ID Detector Input for connections ID Common contact for connections ID 4 Fire Alarm Input for emergency opening device Common...
  • Page 12: Parameters Of Control Signals

    TTD-08A Electromechanical Box Tripod Turnstile On control board there is a microcontroller, which processes incoming control commands (inputs Unlock A, Stop, Unlock B and Fire Alarm), traces the condition of barrier arms optical sensors and basing on received data generates commands on control unit of the turnstile.
  • Page 13: Control Modes Of The Turnstile

    Assembly & Operation Manual Note: For generation of high-level signal at all input contacts (“Unlock A”, “Stop”, Unlock B”, “Fire Alarm” and “Detector”) 2kOhm resistors connected to the power supply bus “+ 5 V” are used Figure 6 – ACS control element - normally open relay contact Figure 7 –...
  • Page 14: Algorithm Of The Control Mechanism

    TTD-08A Electromechanical Box Tripod Turnstile The control mode is set by removal / installation of the jumper on a J1 connector on control board. The J1 connector location is shown in Fig. 5. An installed jumper corresponds to the pulse control mode. In order to switch to potential mode, uninstall the jumper. The change of control mode will take place after switching on the turnstile.
  • Page 15: Control Devices Of The Turnstile

    Assembly & Operation Manual 4. After the passage is complete, barrier arms rotation angle is monitored by microcontroller with optical sensors of control mechanism. With rotation angle of more than 67° the act of passage is registered. One of relay outputs PASS A or PASS B, according to the direction of the passage, becomes active.
  • Page 16: Emergency Opening Device Fire Alarm

    TTD-08A Electromechanical Box Tripod Turnstile Standard orientation of RC panel in regard to the housing is shown in Fig. 8. If working space of the operator is located on the opposite side of the housing, then for convenience of operation it is necessary to swap RC panel cables, connected to contacts Unlock A and Unlock B, as well as Led A and Led B correspondingly (see Table 2).
  • Page 17: Additional Devices Connectable To The Turnstile

    Assembly & Operation Manual The ACS controller inputs are connected to the contacts Common, PASS A, PASS B of the XS1 connector block and to the contacts Ready and Det Out of the XT1.H connector block. Pin assignments of the connector blocks are given in Fig. 13. 5.4 Additional devices connectable to the turnstile 5.4.1 Relay outputs...
  • Page 18: Id And Siren

    TTD-08A Electromechanical Box Tripod Turnstile 5.4.2 ID and siren Warning! Installation of intrusion detector inside the turnstile housing is not anticipated. Intrusion detector is connected to contacts Detector, GND and +12V of connector block XT1.L of control board. Characteristics of input signals are indicated in sec. 5.2.5. Current condition of intrusion detector is transmitted on relay output DETECTOR (contacts Det Out and Common of connector block XT1.H).
  • Page 19: Operation Contingencies And Response

    Assembly & Operation Manual 5.5 Operation contingencies and response Turnstile anticipates an alarm function of standard mode violation in case of unauthorized passage and in case of late barrier arms resetting to the home (closed) position. Barrier arms turn is controlled by activation of rotation unit light sensor. Sensor gets activated with barrier arms turn angle wider than 8 degrees from the home (closed) position.
  • Page 20: Marking And Packaging

    TTD-08A Electromechanical Box Tripod Turnstile MARKING AND PACKAGING The turnstile has a marking sticker on the internal side of the turnstile top cover and a label – inside, on the rear side of the turnstile housing. The label contains trademark, contact information of the manufacturer, production date, power-supply voltage, power consumption.
  • Page 21: Safety Requirements

    Assembly & Operation Manual SAFETY REQUIREMENTS 7.1 Installation safety requirements The installation should be carried out only by the qualified personnel after careful study of this Manual. Warning! • All the cables should be connected up when the power supply is switched off from the AC mains.
  • Page 22: Installation Instructions

    TTD-08A Electromechanical Box Tripod Turnstile INSTALLATION INSTRUCTIONS Follow the safety requirements during the installation (see Clause 7.1). 8.1 Installation details Proper installation is critical to performance and serviceability of the turnstile. We strongly advise to study this section before installation work, and follow the instructions to the latter.
  • Page 23 Assembly & Operation Manual By organization of the passage zone it is essential to anticipate an extra emergency exit. For example, “anti-panic” hinged section of PERCo-BH02 railing (ref. Section 9.4) can serve as such an exit. Figure 12 – Cable layout inside the housing 1 –CLB;...
  • Page 24: Installation Tools

    TTD-08A Electromechanical Box Tripod Turnstile 8.2 Installation tools • 1.2÷1.5 kW hammer drill; • Ø16 mm hard-alloyed drill bits; • Floor chaser for electric raceway; • Flat slot screwdriver No.2; • Cross-head screwdriver; • Horn-type and socket wrenches: S17, S13 and S10;...
  • Page 25: Connection Layout Of The Turnstile And Optional Equipment

    Assembly & Operation Manual 8.4 Connection layout of the turnstile and optional equipment Figure 13 – Connection layout of the TTD-08A turnstile and optional equipment Elements of the scheme are listed in Table 4 Elements, marked with a star sign (*) are not...
  • Page 26 TTD-08A Electromechanical Box Tripod Turnstile Table 4 – Elements of the connection layout Legend Name Q-ty Control mechanism A1.1 Rotation sensor unit A1.2 Electromotors A1.3 Electromagnet A2, A3 Sidewalls with side covers assembly Indication modules (on IM1 jumpers are in L position, A2.1, A3.1...
  • Page 27: Installation Procedure

    8.3. Connection layouts of the turnstile and optional equipment are presented in sec. 8.4. Item numbers are listed in accordance to Fig. 2. Figure 14 – TTD-08A turnstile housing installation layout During turnstile installation keep to the following procedure: 1.
  • Page 28 To connect card readers use free contacts (15 - 24) of the remote connector block XS1. Attention! Possibility of PERCo card reader’s installation is anticipated in the turnstile housing. With installation of third manufacturers readers they should correspond with following technical characteristics: overall readers dimensions ........
  • Page 29: Operation Instructions

    Assembly & Operation Manual OPERATION INSTRUCTIONS When operation the equipment, observe precautions (Clause 7.2). Warning! • Do not move through the turnstile passage area any objects with dimensions exceeding the width of the passageway. • Do not jerk and hit any elements of the turnstile so as to prevent their mechanical deformation.
  • Page 30 TTD-08A Electromechanical Box Tripod Turnstile Table 5 – Pulse control mode (the jumper is set on the J1 connector) Indication The turnstile Actions Turnstile status On the RC On the operating to do panel turnstile modes The red The “Red...
  • Page 31: Operating Modes Of The Turnstile At Potential Control Mode

    Assembly & Operation Manual 9.3 Operating modes of the turnstile at potential control mode See Table 6 for the operating modes set from the RC panel. Setting the operating modes for each direction is independent, i.e. setting the operating mode for one direction does not change the operating mode set earlier for the opposite one.
  • Page 32: Troubleshooting

    CLB XS1 connector block the RC panel In case of other faults and defects, please apply to the PERCo Technical Support Department (the PERCo TSD).
  • Page 33: Maintenance

    Assembly & Operation Manual MAINTENANCE The turnstile maintenance is required once a year and in case of any technical failures the turnstile must be serviced immediately after repair works. The maintenance should be carried out by qualified mechanic only after careful study of this Manual. To do maintenance proceed as follows: 1.
  • Page 34: Transportation And Storage

    14. Check operation of the turnstile in accordance with Section 9 of this Manual. After maintenance works are complete the turnstile is ready for further operation. In case of any defects revealed during visual check please apply to the PERCo Technical Support Department (the PERCo TSD).
  • Page 35: Appendix 1. Control Signal Algorithm At Pulse Control Mode

    Assembly & Operation Manual APPENDIXES Appendix 1. Control signal algorithm at pulse control mode Note: For the RC panel: • active front — pressing of the relevant button on the RC panel; • low level— the relevant button on the RC panel has been pressed; •...
  • Page 36: Appendix 2. Control Signal Algorithm At Potential Control Mode

    TTD-08A Electromechanical Box Tripod Turnstile At this command the passage direction A opens until the command «Always locked» is received; the status of the passage direction B does not change at that. Free passage in the direction B (open for free passage in the direction B) Active front is at the contact “Unlock B”...
  • Page 37 PERCo P.O. Box 87, Saint Petersburg, 194295, Russia Tel: +7 812 321 61 72 Fax: +7 812 292 36 08 E-mail: export@perco.ru support@perco.ru www.perco.com...
  • Page 38 export@perco.ru...